Installation site 

The  external  control  panel  includes,  among  other  things,  buttons for  operating  the  swimming  pool 
cover. For this reason, the external control panel may only be installed in a location that allows an 
unrestricted  view  of  the  entire  swimming  pool.  The  external  control  panel  must  not  be  installed  in 
positions  from  which  the  swimming  pool  cannot  be  fully  viewed!  It  is  not  suitable  for  installation 
outside of buildings. 

Mounting 

The  control  panel  is  designed  for  flush  mounting  using  the  tile  frame  supplied.  Before 
opening the housing, the device must be de-energized. 

The tile frame is installed by the tiler while the tiles are being laid. 

1.) 

Prepare the tile frame: 

Bend all four fastening tabs backwards and then outwards. 

Tile frame 

Bend the fastening 
tabs backwards 

Bend the fastening tabs outwards 

 

 

 

2.) 

Make  a  recess  at  the  intended  mounting  location  in  the  wall,  which  will  later 
accommodate the tile frame and the housing. 

3.) 

Align the tile frame in front of the wall recess as follows: 

  horizontally 

  perpendicular 

 

the front edge of the tile frame must be flush with the tiles!

 

4.) 

Fix the fastening tabs to the wall with screws or nails and fix them with mortar or tile 
adhesive. 

5.) 

Lay tiles right up to the outer edge of the tile frame. 

Installation of the control panel in the tile frame 

The installation of the control panel in the tile frame is done by an electrician after the wall 
has been covered with tiles and grouted. 

1.) 

Lead connecting cable through the cable gland, and then tighten the pressure screw 
of the screw. The cable entry must be watertight. 

2.) 

Insert  the  metal  housing  into  the  tile  frame  and  fasten  it  with  the  enclosed  4mm 
stainless steel screws. A screw is screwed into each of the 4 corners. 

3.) 

Connect  the  cable  to  the  control  panel  in  accordance  with  the  installation  and 
operating instructions. The clamps are on the back of the board. 

Содержание TOUCH 310.000.0700

Страница 1: ...ontrol EUROMATIK net PC 40 net PC 45 exclusiv Dosing control WATERFRIEND MRD 1 MRD 2 or MRD 3 RGB Lighting controller Color Control NET with 3 Attractions Attraction control for 6 attractions and Attr...

Страница 2: ...bout touch display 7 Time date 7 Language 7 Screen lock settings 7 Infoscreen settings 8 Add OSF device LAN connection 8 Service functions 9 Touch screen calibration 9 Factory settings 9 Network setti...

Страница 3: ...tabs outwards 2 Make a recess at the intended mounting location in the wall which will later accommodate the tile frame and the housing 3 Align the tile frame in front of the wall recess as follows ho...

Страница 4: ...e phase or AC cables in the same cable duct In general laying low voltage cables near three phase or AC cables must be avoided Wiring diagrams The power supply for the touch control panel can either b...

Страница 5: ...4 1 Color control net D D D D twisted wire osf Bus 12V supply Euromatik net 12VGND D D 58 61 62 57 Waterfriend MRD 3 2 1 Data Data D D Note the polarity of the bus line more external touch operating...

Страница 6: ...local network The easiest way is to connect all network devices to a network switch The range includes the suitable cluster switch plus A standard network cable patch cable CAT5 must be used for conne...

Страница 7: ...ructure The button leads to the main menu of the display settings Display settings In this menu settings are made that relate to the external control panel itself and not to the devices connected to i...

Страница 8: ...s parameter defines after how many minutes of inactivity the control panel screen automatically switches to the display mode of the info screen If the time has not been set the info screen can be swit...

Страница 9: ...factory settings All operational logs remain unchanged Network settings The factory LAN settings of the smart touch device enable plug and play remote control If necessary you can set the IP address m...

Страница 10: ...tuation Manual operation In this menu it is possible to switch on the filter pump manually outside of the filter cycles and to start the backwashing manually Pool settings Info display Utility functio...

Страница 11: ...and control colored pool lighting and to control three attractions Edit color program The color programs can be edited in this menu after you have previously selected the program for editing Scenes o...

Страница 12: ...r Control net can control 10 zones independently of each other In order to implement a complex color composition consisting of several DMX projectors that light up in different colors different projec...

Страница 13: ...e screen The minus button removes a device from the list of available devices Here you can set time limits and timers for the 3 attractions It is possible to program 15 independent switching cycles pe...

Страница 14: ...Smart Page 14 of 14 Further information can be found on the Internet at the following address https osf de download documents documents php device smart Touch We wish you much joy and relaxation in yo...

Отзывы: