Service functions 

The second display settings screen contains utility functions. The menu is initially 
locked to prevent accidental changes. Press the key symbol for 3 seconds to 
unlock. 

Touch screen calibration 

In  this  menu  you  can  calibrate  the  touchscreen.  Calibration  of  the  display  is 
required if the device does not correctly recognize finger touches. 

To perform the calibration, follow the on-screen instructions, three times touch the 
squares  in  different  places  on  the  screen,  and  save  the  calibration  results  by 
pressing the "OK" button. 

Factory settings 

By pressing the "YES" key, all user parameters are reset to the factory settings. All 
operational logs remain unchanged. 

Network settings 

The  factory  LAN  settings  of  the  smart  touch  device  enable  plug-and-play  remote 
control. If necessary, you can set the IP address manually and prevent the device 
from  communicating  with  the  OSF  communication  server.  (For  details,  see 
"Internet Connection" section.) Access to change settings via LAN is restricted by a 
PIN code, which can be viewed and changed here. 

 

 

Menus of the connected devices 

Euromatik.net 

The  menu  structure  of  the  Euromatik.net  control  unit  on  the  external  smart  touch  panel  largely  repeats  the 
structure  of  the  display  menu  on  Euromatik.net's  own  display  and  shows  the  most  important  and  required 
parameters and settings. 

 

 

 

Swimming pool cover 

Before  operating  these  switches,  the  swimming  pool  must  be  subjected  to  a 
visual inspection. The swimming pool cover may only be moved if it is certain that 

Содержание TOUCH 310.000.0700

Страница 1: ...ontrol EUROMATIK net PC 40 net PC 45 exclusiv Dosing control WATERFRIEND MRD 1 MRD 2 or MRD 3 RGB Lighting controller Color Control NET with 3 Attractions Attraction control for 6 attractions and Attr...

Страница 2: ...bout touch display 7 Time date 7 Language 7 Screen lock settings 7 Infoscreen settings 8 Add OSF device LAN connection 8 Service functions 9 Touch screen calibration 9 Factory settings 9 Network setti...

Страница 3: ...tabs outwards 2 Make a recess at the intended mounting location in the wall which will later accommodate the tile frame and the housing 3 Align the tile frame in front of the wall recess as follows ho...

Страница 4: ...e phase or AC cables in the same cable duct In general laying low voltage cables near three phase or AC cables must be avoided Wiring diagrams The power supply for the touch control panel can either b...

Страница 5: ...4 1 Color control net D D D D twisted wire osf Bus 12V supply Euromatik net 12VGND D D 58 61 62 57 Waterfriend MRD 3 2 1 Data Data D D Note the polarity of the bus line more external touch operating...

Страница 6: ...local network The easiest way is to connect all network devices to a network switch The range includes the suitable cluster switch plus A standard network cable patch cable CAT5 must be used for conne...

Страница 7: ...ructure The button leads to the main menu of the display settings Display settings In this menu settings are made that relate to the external control panel itself and not to the devices connected to i...

Страница 8: ...s parameter defines after how many minutes of inactivity the control panel screen automatically switches to the display mode of the info screen If the time has not been set the info screen can be swit...

Страница 9: ...factory settings All operational logs remain unchanged Network settings The factory LAN settings of the smart touch device enable plug and play remote control If necessary you can set the IP address m...

Страница 10: ...tuation Manual operation In this menu it is possible to switch on the filter pump manually outside of the filter cycles and to start the backwashing manually Pool settings Info display Utility functio...

Страница 11: ...and control colored pool lighting and to control three attractions Edit color program The color programs can be edited in this menu after you have previously selected the program for editing Scenes o...

Страница 12: ...r Control net can control 10 zones independently of each other In order to implement a complex color composition consisting of several DMX projectors that light up in different colors different projec...

Страница 13: ...e screen The minus button removes a device from the list of available devices Here you can set time limits and timers for the 3 attractions It is possible to program 15 independent switching cycles pe...

Страница 14: ...Smart Page 14 of 14 Further information can be found on the Internet at the following address https osf de download documents documents php device smart Touch We wish you much joy and relaxation in yo...

Отзывы: