6
defaults to 26 ° C.
⚫
After selecting one of the 5 modes, the corresponding mode will run after 10s.
⚫
Solar energy is the priority, and electricity is used without solar energy. Please plug in the power
when there is electricity, or the automatic vents may not close when the clouds suddenly block
the sun. The power supply can reduce the operation times of the automatic air outlet and reduce
the noise.
Time setting
The correct clock must be set for the collector to work normally. To set the clock, press the SET and
M buttons at the same time for more than 2 seconds.
Mode selection
Wind speed adjustment in current mode:
1.Automatic mode in solar
:
Ventilation start time, the default is 4 am;
:
Switch to heating outdoor fresh air, default 12 o'clock at noon;
:
Switch to continuous heating of indoor air, default 15 o'clock.