background image

ROMANCE 28 

23 

 

1700, rue Leon-Harmel, Québec (Quebec) G1N 4R9 

tel. : (418) 527-3060    fax : (418) 527-4311 

e-mail : [email protected]    web site : www.osburn-mfg.com 

LIMITED WARRANTY 

The  warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers brand 
new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated bill of 
sale), model name and serial number must be supplied when making any warranty claim to your Osburn  dealer.  

This warranty applies to normal residential use only.  Damages caused by misuse, abuse, improper installation, lack of maintenance, 
over firing, negligence or accident during transportation are not covered by this warranty. 

This warranty does not cover any scratch, corrosion or discoloration caused by over firing, abrasives or chemical cleaners. Any defect 
or damage caused by the use of unauthorized parts or others than original parts void this warranty. 

An authorized qualified technician must perform the installation in accordance with the Instructions supplied with this product and all 
local and national building codes. Any service call related to an improper installation is not covered by this warranty. 

Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the 
manufacturer will repair or replace such defect and reasonable transportation fees will be refunded. Repair work covered by the 
warranty, executed at the purchaser domicile by an authorized qualified technician requires the prior approval of the manufacturer. 
Labour cost and repair work to the account of  the manufacturer are based on predetermined rate schedule and must not exceed the 
wholesale price of the replacement part. 

The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect. The 
manufacturer  may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of any 
warranted but defective parts  

The manufacturer shall in no event be responsible for any special, indirect, consequential damages of any nature, which are in excess 
of the original purchase price of the product. 

WARRANTY APPLICATION 

DESCRIPTION 

PARTS LABOUR 

Combustion chamber (weldings only) 

5 years 

5 years 

Stainless baffle 

5 years 

1 year 

Carbon Steel baffle 

2 years 

1 year 

Gas Valve, piezo, thermopile, thermoswitch, burner 

1 year 

1 year 

Logs 

N/A N/A 

Ceramic glass (thermal breakage only) 

5 years 

N/A 

Paint, gasket, blower, Blower thermoswitch and rheostat 

1 year 

N/A 

Gold plating (tarnishing) 

5 years 

N/A 

Shall your unit or a components be defective, contact immediately your 

Osburn

 dealer. Prior to your call make sure you have the 

following information necessary to your warranty claim treatment: 

• 

Your name, address and telephone number;  

• 

Bill of sale, dealer’s name; 

• 

Serial number and model name as indicated on the 

nameplate fixed to the back of your unit; 

• 

Nature of the defect and any relevant information. 

Before shipping your unit or defective component to our plant, you must obtain from your Osburn dealer an Authorization 
Number. Any merchandise shipped to our plant without authorization will automatically be refused 

and 

returned to sender.

 

 

f i r e - p a r t s . c o m

Содержание Romance 28

Страница 1: ...ppliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach yo...

Страница 2: ...Critical Length of Venting Pipes 11 Stove conversion for a B Vent installation only 12 Gas Piping 14 Logs Installation 14 Ember Kit Installation 15 OPERATING YOUR STOVE 16 For your safety 16 Lighting...

Страница 3: ...n and Safety Standard Title 24 CFR Part 3280 or when such a standard is not applicable the current Standard for Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA...

Страница 4: ...7 lbs 113 kg Color Metallic black Clearances to Combustibles Back 7 po 180 mm Side 7 po 180 mm Corners 4 po 100 mm Top 36 po 915 mm Combustible Floor Note 1 Note 1 Your stove has been successfully cer...

Страница 5: ...the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less that psi 3 5 kPa NATURAL GAS...

Страница 6: ...E CANADIAN ELECTRICAL CODE CSA C22 1 Positioning the Stove Always locate the stove as near as possible to an outside wall Keep horizontal run of vent pipe as short as possible Provide adequate clearan...

Страница 7: ...g your appliance CLEARANCE Back in 7 Side in 7 Corners in 4 Top in 36 Front in 36 Pipe in 1 Floor Combustible Note 1 Corner Installation Direct Installation Note 1 Your stove has been successfully cer...

Страница 8: ...the table The example on the table is showing a possible installation with five 5 feet of horizontal run and fifteen 15 feet of vertical rise The venting system starts with a 45 elbow at the stove le...

Страница 9: ...earance to service regulator vent outlet J 12 Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance K 72 Clearance to a mechanical air supply inle...

Страница 10: ...7b 4 If necessary cut the wall thimble 7a and 7b according to the wall thickness Slide part 7a and 7b into place and secure with 8 wood screws 10 x 1 5 Install and secure the snorkel termination cap 8...

Страница 11: ...necessary cut the wall thimble 7a and 7b according to the wall thickness Slide part 7a and 7b into place and secure with 8 wood screws 10 x 1 5 Install and secure the snorkel termination cap 8 with 1...

Страница 12: ...NVENTIONAL 6 INCH PIPE ALONE Critical Length of Venting Pipes 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 0 1 2 3...

Страница 13: ...an buy a conversion kit to be able to install it as a B Vent unit To convert your stove just follow the instructions 1 Remove the decorative top 1 by unscrewing the two screws under the center plate t...

Страница 14: ...ney connector Install the venting hood 5 by sliding it into place Screw tightly in place 5 Remove the four screws of the valve cover 7 and slide upwards to remove 6 Unscrew the thermocouple 8 from the...

Страница 15: ...gs Installation 1 Place the rear log 1 against the rear log holders Make sure grooves behind the log line up with the holders 2 Place logs 2 and 3 against the holders in the middle of the burner Make...

Страница 16: ...ht up performance delayed ignition affect flame aspect and form carbon deposit on logs 1 Place some pieces of rock wool fibers approximately 1 2 large behind the front gas ports 2 Light the stove Modi...

Страница 17: ...by the curing of the high heat paint Open a window to get fresh air inside the house The ceramic glass window may require cleaning after this initial fire Please read the instructions on cleaning in t...

Страница 18: ...temperature You need to choose a convenient location for the thermostat Remember that it should be at least 10 feet from the stove and away from direct radiation of the fire Run the correct gauge wir...

Страница 19: ...air toward the front the blower enables you to extend the radiation power of your stove You can purchase this option through your OSBURN dealer Make sure to specify this part number AC02050 You can a...

Страница 20: ...e back of the stove on the lower right corner Refer to the drawing on this page Note The blower will start when the temperature at the back of the stove where the air is circulated reaches 110 O F 43...

Страница 21: ...not possible Check the burner for flame lifting or for unusual flame pattern If necessary clean the burner orifice For more information see Adjustments in the INSTALLATION section Keep the area clear...

Страница 22: ...he o ring gasket must be in place between the main orifice Screw the burner back into the bottom of the combustion chamber WARNING The main orifice burner must be well inserted into the venturi tube o...

Страница 23: ...ment Installation AC02010 REMPLACEMENT PARTS DESCRIPTION PART 5 logs set AC05791 Burner natural gas and propane SE09011 02 Orifice natural gas 9071 Orifice propane gas 9071 01 Honeywell pilot for natu...

Страница 24: ...d technician requires the prior approval of the manufacturer Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale p...

Отзывы: