8
The
Strainer
over the drain opening in the tank prevents debris from entering the drain
when the tank is emptied. It should be rinsed after emptying the tank before refilling
with fresh liquid.
The
Heater
is located behind the perforated Heater Shield. It heats the water in the
tank.
The
Spray Nozzle
directs the flow of liquid into the tank. The spray nozzle can be
removed for cleaning if the holes are clogged. Simply unscrew the nozzle and rinse with
tap water to un-clog holes.
The
Pump Intake Screen
prevents large particulates from entering the pump. It may
occasionally need to be cleaned with a soft brush or toothbrush to remove debris
trapped in the holes.
The
Temperature and Level sensors
are used to sense the temperature and height of
the liquid in the tank. They are mounted behind the rear support bracket.
The
Main Power Switch
is located on the right-hand side of the unit. This turns power to
the unit on and off.
Figure 4
Unit Front and Side Area
Drain Tube
Drain Valve
(Closed Position)
Power Switch
Power Cord
Receptacle