Problem 

Probable Causes 

What to Do 

Pump and 
heater will not 
start 

Power is not on 

Check the power indicator 

 on the front control 

panel.  If it is off press the

 button. If still unlit, then 

proceed to the “Power Indicator is not Lit” Problem.

 

Timer has not been 
set and started 

The system will only run when the timer is counting 
down. Check the timer display on the control panel. 

 

If it is not counting down, press the 

 button. 

 

If the time being displayed is 00:00, then add time 

and start the system. 

Liquid level is too 
high or too low 

Check the indicator lights on the right side of the display 
control panel.  If either level indicator is on, add or 
remove water from the tank until the indicator turns 

off. Press the 

 button to restart. 

Liquid temperature 
is too high 

 

Error Code: 

 

EO = over 
temperature 

Check the indicator lights on the right side of the display 
control panel.  If the Alert light is on, open the lids and 
lift the part basket from the tank. 
Let the liquid cool and try starting the cycle again. 
If it overheats a second time, contact technical support

 

Over-temperature 
sensor has tripped 

A resettable over-temperature sensor located on the 
back wall of the tank turns off the unit if the 
temperature of the bath exceeds 95

C.  For instructions 

on resetting this sensor, contact technical support. 

Pump or Heater has 
failed 

Contact technical support. 

Buzzer is going 
off 
 
Silence the 
buzzer by 

pressing the 

 

button 

Liquid level is too 
high or too low 

Check the indicator lights on the right side of the 
control panel.  If either level indicator is on, add or 
remove water from the tank until the indicators go off.  

Liquid temperature 
is too high 

 

Error Code: 

 

EO = over 
temperature 

Check the indicator lights on the right side of the 
control panel.  If the Alert indicator is on, open the lids 
and lift the parts basket from the tank. 
Let the liquid cool and try starting the cycle again. 
If it overheats a second time, contact technical support. 

Содержание SCA 1200ht

Страница 1: ......

Страница 2: ...2 This page intentionally left blank...

Страница 3: ...sposal 10 Operation 11 Filling and setup 11 Preheating and starting the cleaning cycle 12 Completing the cleaning process 15 Maintenance 16 Draining the tank 16 Disposing of solution 16 Cleaning the S...

Страница 4: ...require the unit to be plugged into a Ground Fault Interrupt GFI or similar protected outlet Always power off and unplug the SCA from the power outlet when it is being cleaned moved or serviced Do no...

Страница 5: ...out autre fin que de retirer les mat riaux de support solubles de pi ces 3D imprim es Portez des gants thermiques et des lunettes de s curit lorsque vous travaillez avec ou proximit du SCA Reportez vo...

Страница 6: ...is completely removed models are unloaded from the SCA rinsed dried and ready for further finishing or use Package contents The SCA is shipped with the following contents SCA System 1 Large Part Bask...

Страница 7: ...e liquid in the tank The Large Parts Basket is used to hold parts during cleaning and to lift parts out of the tank Users should wear thermal gloves when lifting the basket from the tank The Small Par...

Страница 8: ...ply unscrew the nozzle and rinse with tap water to un clog holes The Pump Intake Screen prevents large particulates from entering the pump It may occasionally need to be cleaned with a soft brush or t...

Страница 9: ...lity The tank is drained by connecting a hose to the Drain Tube and turning the Drain Valve to the open position The liquid in the tank should be at room temperature and the unit should be turned off...

Страница 10: ...should be easily accessible at all times Position the unit so that the plug can be easily reached It is strongly recommended that the unit be placed on a circuit with its own GFCI breaker Place the un...

Страница 11: ...ank unless the liquid level is above the MIN line as shown N UTILISEZ PAS d eau chaude lors du remplissage du r servoir L ajout de concentr s de nettoyage l eau est une r action de d gagement de chale...

Страница 12: ...s SDS for PPE and handling requirements If using EcoWorks 1 Open the foil cleaning agent packet as shown Each packet contains an A B pouch 2 Empty all the contents of 6 6 foil cleaning agent packets...

Страница 13: ...to the cleaning solution press the button to pause the heater and pump With the basket cutout facing the nozzle slowly lower the large parts basket into the solution filled tank The flow nozzle should...

Страница 14: ...opening the lid carefully lifting the Large Parts Basket from the tank turning the basket 90 and resting it on the rear support bracket and then pulling it forward on to the front tank ledge Protecti...

Страница 15: ...des pi ces mouill es avant qu elles n aient t rinc es Let the basket rest above the tank while draining After draining remove the parts from the basket and rinse them with water to remove any residua...

Страница 16: ...fluents Power off the unit and unplug from the wall receptacle Ensure the drain strainer is in place at the bottom of the tank Attach a 1 inch 25 4 mm inner diameter hose or tubing to the end of the d...

Страница 17: ...erior surfaces of the SCA and the inside of the tank Never immerse the system Any liquid in the electronics area of the system may cause damage or system failure and void the warranty Contact the manu...

Страница 18: ...face Scrub debris from the intake screen using a stiff brush Rinse with water Verify all holes are unplugged before replacing the screen on the pump intake Moving the SCA Always use two people to lift...

Страница 19: ...Large basket Small parts basket Pump subassembly w nozzle Heater subassembly Sensor subassembly Display Control Panel PCB subassembly Power switch Spray nozzle Figure 11 SCA 1200ht Assembly List of Re...

Страница 20: ...ET DES YEUX Problem Probable Causes What to Do Power Indicator is not Lit after pressing the button Power switch is not On Press rocker switch on the right side of the unit to the On position Power co...

Страница 21: ...l If the Alert light is on open the lids and lift the part basket from the tank Let the liquid cool and try starting the cycle again If it overheats a second time contact technical support Over temper...

Страница 22: ...t Pump intake screen is clogged Drain the tank as instructed in the Maintenance section Clean the intake screen with a stiff brush until debris is removed from the holes Flow from nozzle is not unifor...

Страница 23: ...Works is a more efficient cleaning concentrate Liquid Level indicators did not turn off when liquid was added removed from the tank Sensors or Indicators have failed Contact technical support System i...

Страница 24: ...es 10 x 10 x 10 cm Operating Environment Ranges Temperature 5 C 40 C Humidity 0 80 RH Altitude 0 M 2000 M Temperature Control Accuracy 2 C Pump Max Flow Rate 10 GPM 38 LPM Temperature Display Digital...

Страница 25: ...unit was purchased Otherwise to receive technical support www oryxadditive com support proceed to the Request Technical Support page and fill out the support request form send an e mail to support or...

Страница 26: ...ct accident improper installation improper maintenance or improper operation or application or if the machine was improperly repaired or serviced by the customer This warranty is void if the system is...

Отзывы: