Figure 4. Diagram of connection “Lind-EM” ICD to “Lun-9T”/”Lun-9P” Control Panel

АДМА.425713.005 РЭ

Rev. en_3

10

Содержание Lind-EM

Страница 1: ...ons therefore meeting the requirements of this document is mandatory Lind EM Proximity Identification Card Reader Operating Manual ORTUS Group Product Compatibility Table Control Panel Lun 11 Lun 11 mod 2 Lun 9T Lun 7T Version GSM Control Panel Configuration Software Configurator 11 Version Central Monitoring Station Orlan M11 modules based Orlan Orlan Version ...

Страница 2: ...s 4 4 Arming 5 5 Disarming 6 6 Fire alarm reset Lun 11 Lun 11mod 2 6 7 Maintenance 7 8 Operating conditions 7 9 Storage 7 10 Transportation 7 11 Disposal 7 12 Appendix 1 Connection diagrams 8 13 Appendix 2 Warranty Service Regulations 11 АДМА 425713 005 РЭ Rev en_3 2 ...

Страница 3: ...r hidden video and audio recording 2 Design The reader is a compact device placed in a plastic housing designed for installation on a flat surface eg wall To connect to the alarm system it has three multi colored insulated wires Figure 1 Figure 1 Lind EM reader Wires assignment described in Table 1 connection diagrams to Control Panels see at Figures 2 3 4 Table 1 Lind EM reader s wires assignemen...

Страница 4: ...ng In Lun 11 Lun 11mod2 working mode and in the absence of communication with the Control Panel for more than 3 seconds the LED flashes with a frequency of 10 Hz 10 times per second When you try to arming Control Panel when some zones is violated LED indicates the number of the first violated zone but no more than 8 zones by corresponding number of flashes If the number of the first violated zone ...

Страница 5: ...ring the exit delay countdown beeps this time out should be set during configuration previously Attention The LED displays the status of the one group only previously selected during configuration process Triggering sensors for delayed and interior delayed zones will not be alarm during the exit delay countdown You can monitor the arming process by watching the remote LED from outside of the objec...

Страница 6: ...ound and LED on the reader will go off If the card fob is not registered in the Control Panel then disarming is impossible Buzzer sounds long intermittent signal for Lun 7T Control Panel without sound Attention If the time out ends but the object group is not disarm and the siren is on you should bring allowed identification card or key fob to the reader closely Siren will be off 6 Fire alarm rese...

Страница 7: ...e manufacturer s package 10 Transportation 1 Product transportation shall be carried out in the manufacturer s package 2 Product is allowed to be transported by all types of enclosed transporters subject to observing the shipping rules applicable for each type of transport 3 Product transportation requirements in the terms of the impact of mechanical factors shall be Group 2 according to GOST 1299...

Страница 8: ...n diagram is mandatory Failure to comply with this requirement can lead to breakdown of the device and consequently to impossibility of performance of the warranty liabilities Figure 2 Diagram of connection Lind EM ICD to Lun 11 Control Panel АДМА 425713 005 РЭ Rev en_3 8 ...

Страница 9: ...Figure 3 Diagram of connection Lind EM ICD to Lun 7T Lun 73T Control Panel АДМА 425713 005 РЭ Rev en_3 9 ...

Страница 10: ...Figure 4 Diagram of connection Lind EM ICD to Lun 9T Lun 9P Control Panel АДМА 425713 005 РЭ Rev en_3 10 ...

Страница 11: ...tion of the Equipment 8 Manufacturer shall not be liable under the Warranty if the test and or analysis conducted by the Manufacturer shows that the product has no claimed defect or it that this defect is the result of violation of the installation rules or operation conditions as well as of any actions to make the device perform the functions not stated by the Manufacturer 9 Warranty terms do not...