Direction for Use AcceleDent® Aura 

Back to Contents

Use Schedule

Use AcceleDent Aura for twenty minutes per day hands-free and 

the small vibrations, or 

micropulse

s will help your teeth respond to 

orthodontic treatment more quickly.
Select a consistent time for use each day. This way, it becomes a 

routine and you are less likely to forget. Try to find a time that you can 

use AcceleDent Aura uninterrupted – it is best not to stop use in the 

middle of a session. It is fine to adjust the external unit with your hand 

occasionally.
Some patients prefer using AcceleDent Aura just after they wake up 

and brush their teeth in the morning. Others use the appliance while 

engaged in a consistent daily activity, such as reading or watching 

TV. Try several approaches and decide on the approach that works 

best for you. Plug the USB into the computer to upload and view the 

FastTrac.htm usage report. Refer to the 

“FastTrac”

 section for further 

details.
You may easily pause and resume use if you are interrupted during a 

session. To pause, press the Power Button on the Activator. When you 

are ready to resume, press it again to unpause. AcceleDent Aura will 

remember how long you used it as long as the interruption does not 

exceed 5 minutes. After 5 minutes of being turned off, AcceleDent Aura 

will operate for a full session of 20 minutes at its next use.
AcceleDent Aura features a Half-Time Indicator, which will pulse 3 times 

at the 10-minute mark to signal that ten minutes has elapsed.
The Activator is 

not moisture resistant

 and should not be exposed 

to water or high humidity. The Mouthpiece is waterproof and may be 

cleaned  under  running  water  after  first  being  disconnected  from  the 

Activator.
No component of AcceleDent Aura is dishwasher safe. Hand-clean only.

Travel Case

The Travel Case serves two purposes:
1)   As a convenient carrying case for patients who use  

AcceleDent Aura daily in locations away from home. 

2)   To securely store the Activator, Mouthpiece, Power Adapter and 

USB Extension Cord.

Содержание AcceleDent Aura

Страница 1: ...Direction for Use AcceleDent Aura OrthoAccel Technologies Inc...

Страница 2: ...thoAccel is a registered trademark of OrthoAccel Technologies Inc AcceleDent is a registered trademark of OrthoAccel Technologies Inc AcceleDent Aura is covered by one or more of the following US pate...

Страница 3: ...4 4 5 2 0 Use Set Up and Charging the Unit Steps for Use and Use Schedule Travel Case FastTrac Usage Report 6 9 9 10 3 0 Care Cleaning Storage Replacement Disposal 12 12 12 13 4 0 Safety Voltage Water...

Страница 4: ...bout any questions or concerns that are specifically related to AcceleDent Aura and its components Customer Service Information For assistance contact the OrthoAccel Customer Service Center North Amer...

Страница 5: ...5 Direction for Use AcceleDent Aura Back to Contents Features and Components 1 Activator A Power Button and LED Indicator B USB cover 2 Mouthpiece 3 Power Adapter 4 USB Extension Cable 5 Travel Case...

Страница 6: ...ed on the recommended 20 minute daily usage the activator should be recharged approximately 3 days for a minimum of 2 hours or when the LED indicator is quickly flashing orange Do not let the battery...

Страница 7: ...nd bite down gently Biting lightly with just enough force to hold the AcceleDent Aura in place is ideal It is not necessary to bite with excessive pressure The AcceleDent Aura does not need to be held...

Страница 8: ...M THE ACTIVATOR The activator is not moisture resistant and should not be exposed to water or high humidity See the care section for details 6 Charging the Activator When the LED indicator is quickly...

Страница 9: ...r to the FastTrac section for further details You may easily pause and resume use if you are interrupted during a session To pause press the Power Button on the Activator When you are ready to resume...

Страница 10: ...3 The AcceleDent Daily Usage Table The AcceleDent Usage Summary summarizes the Total Number of Days in Treatment Total Minutes Used Average Use Minutes Day Overall Usage Device Time and Battery Deplet...

Страница 11: ...s type is Text files txt text For Google Chrome choose Webpage Complete Verify the Format selected is Page Source Next Save the file by typing the file name SETCLOCK txt Save the file in Export As as...

Страница 12: ...d Power Adapter Avoid storing the Activator and Mouthpiece in areas where they may be exposed to extreme temperatures Replacement The Mouthpiece is the only component of AcceleDent Aura that may requi...

Страница 13: ...d labeling indicates that separated collection is required for the recycling of electrical and electronic equipment These designated collection facilities are free of charge to the consumer because Or...

Страница 14: ...t Auraoranyofitscomponentsnolongerworksproperlyorneedsrepair NEVER charge your device using an unauthorized AC adapter plug as it may cause permanent damage to your device Never use the USB Extension...

Страница 15: ...ergy such as hand held radio transceivers can interfere with normal operation of the Activator If the Activator exhibits erratic operation make sure it is not in close proximity to a cell phone or any...

Страница 16: ...eledent com Troubleshooting Thissectionlistsseveralofthemorecommonlyobservedtroubleshooting situations If you cannot find the answer to your question here or if the situation you are experiencing is n...

Страница 17: ...S LIMITED WARRANTY OrthoAccel Technologies Inc OrthoAccel warrants that the product packaged with this warranty the Product will be free from significant defects in materials and workmanship under nor...

Страница 18: ...erexpressorimplied Without limiting the generality of the foregoing orthoaccel disclaims any and all other warranties express or implied with respect to the product including its condition the existen...

Страница 19: ...ftPulse Technology to generate small vibrations micropulses enhancing the movements directed by your braces allowing for faster overall treatment Q How do I know if I am biting into the Mouthpiece cor...

Страница 20: ...Why does the device vibrate for a few seconds when first turned on and then stop even though the LED indicator is solid green A If the device turns on for a few seconds and then turns off it is time...

Страница 21: ...f your AcceleDent Aura as you would with any other device with a rechargeable battery Reference the Disposal section of the Directions for Use manual for further details Q What does it mean if my Acti...

Страница 22: ...Environmental operating conditions Ambient temperature range 5 C 40 C Maximum temperature of any external component at maximum ambient temperature 46 C Relative humidity range 15 93 Atmospheric press...

Страница 23: ...extremely close proximity to other electronic equipment Electromagnetic Emissions The Activator is intended for use in the electromagnetic environment specified below The customer or the user of the u...

Страница 24: ...upply lines 1 kV for input output lines 1 kV line s to line s 2 kV line s to earth 3 Alm 3 Alm 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95...

Страница 25: ...tic propagation is affected by absorption and reflection from structures objects and people Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no close...

Страница 26: ...o 2 5 GHz d 2 3 P Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 0 01 0 1 1 10 100 0 12 0 38 12 3 8 12 0 12 0 38 1 2 3 8 12 0 23 0 73 2 3 7 3 2...

Страница 27: ...Phone 61 0 2 9006 1662 Fax 61 0 2 9006 1010 405 0409 001D L67000 Separated collection for electrical and electronic equipment Date of manufacture Manufacturer Lower limit of temperature Upper limit of...

Страница 28: ...acceledent com Back to Contents...

Отзывы: