iv

DANGER

Opening the cover of this instrument is likely to expose dangerous voltages. Disconnect the
instrument from all voltage sources while it is being opened.

WARNING Using this instrument in a manner not specified by the manufacturer may impair the protection

provided by the instrument.

CAUTION To prevent moisture inside of the instrument during external cleaning, use only enough liquid to

dampen the cloth or applicator.

SAFETY INSTRUCTIONS AND SYMBOLS

This manual contains up to three levels of safety instructions that must be observed in order to avoid personal injury
and/or damage to equipment or other property. These are:

DANGER

Indicates a hazard that could result in death or serious bodily harm if the safety instruction is not
observed.

WARNING

Indicates a hazard that could result in bodily harm if the safety instruction is not observed.

CAUTION

Indicates a hazard that could result in property damage if the safety instruction is not observed.

Please read all safety instructions carefully and make sure you understand them fully before attempting to use this
product. In addition, the following symbol may appear on the product:

ATTENTION – Refer to Manual

DANGER – High Voltage

Please read all safety instructions carefully and make sure you understand them fully before attempting to use this
product.

SAFETY WARNINGS AND CLEANING INSTRUCTIONS

Cleaning Instructions

To clean the instrument exterior:

!

Unplug the instrument from the ac power supply.

!

Remove loose dust on the outside of the instrument with a lint-free cloth. 

!

Remove remaining dirt with a lint-free cloth dampened in a general-purpose detergent and water solution. Do not
use abrasive cleaners.

!

Allow the instrument to dry completely before reconnecting it to the power source.

Содержание CryoSecure

Страница 1: ...CryoSecure Compressor Power Controller Hardware Manual Printed in U S A ORTEC Part No 774890 1209 Manual Revision D...

Страница 2: ...o that a Return Authorization Number can be assigned to the unit Also ORTEC must be informed either in writing by telephone 865 482 4411 or by facsimile transmission 865 483 2133 of the nature of the...

Страница 3: ...THE POWER ON SAFE STATE 4 3 3 INSTALLATION IN A WARM SYSTEM 4 3 4 INSTALLATION IN A COLD SYSTEM 4 4 OPERATING INSTRUCTIONS 4 4 1 OPERATIONAL STATES 4 4 1 1 Normal Operation 4 4 1 2 AC Mains Power Fai...

Страница 4: ...zard that could result in bodily harm if the safety instruction is not observed CAUTION Indicates a hazard that could result in property damage if the safety instruction is not observed Please read al...

Страница 5: ...v...

Страница 6: ...vi...

Страница 7: ...output to the compressor is limited to 600 W No power conditioning or conversion is performed The CryoSecure incorporates a microprocessor controlled circuit to detect a mains power failure measure t...

Страница 8: ...the detector bias voltage to be applied DANGER Isolate the controller from the mains power supply before removing the cover DEEP DISCHARGE PROTECTION In the event of a long term power failure or if th...

Страница 9: ...normal working state bypassing the warming and cooling states by pressing and holding the INITIALIZE button for 5 seconds when in the cooling bias off state 4 OPERATING INSTRUCTIONS 4 1 OPERATIONAL ST...

Страница 10: ...e the CryoSecure waits after a mains power failure before restarting the compressor is set with the two rotary selector switches mounted along the top edge of the controller PWB labeled WARM HI and WA...

Страница 11: ...on WARNING Remember to reinstall W3 after testing 5 2 STORAGE AND SHIPPING DANGER Isolate the controller from the mains power supply before removing the cover With the CryoSecure disconnected from the...

Страница 12: ...6...