39
Vent Restrictors
A vent restrictor is a metal plate that reduces the flow of exhaust evacuating the fireplace. A restrictor is only necessary when the
flame is receiving too much oxygen. Various-sized restrictors are supplied with every fireplace. See instructions below to determine
which restrictor, if any, is recommended for your fireplace.
Restrictor Sizing Guidelines
The restrictor sizing tables in this section determine the recommended restrictor for your vent configuration. These tables show Ortal’s
recommendations only. The Environment, gas type and other factors may affect the best restrictor choice.
How to use the “Recommended Restrictor” tables:
1. Find the total vertical rise in your vent configuration along the y-axis.
2. Find the horizontal run in your vent configuration along the x-axis.
3. Follow the desired rise and run values within the table until they meet. This value is the recommended restrictor size (in
inches) for your vent configuration.
Legend:
X: Vent configuration is not allowed. Power vent required.
0
: No restrictor required.
Numbers other than 0: Represents the recommended restrictor (by width).
Restrictor Sizes:
20mm (0.79”)
30mm (1.18”)
40mm (1.57”)
50mm (1.97”)
70mm (2.75”)
85mm (3.35”)
Space Creator Restrictor - Passive Direct Vent
Space Creator Restrictor - Power Vent
NOTE: Space Creator models come with a special restrictor specific to the Space Creator Series. It is not required to
use any other available restrictor.
Series 40-75 Fireplaces
(includes 31H)
V Minimum = 0 Feet
44’
1.97”
X
X
X
X
X
X
X
X
X
X
X
33’
1.97” 1.97” 1.97” 1.97” 1.57” X
X
X
X
X
X
X
30’
1.97” 1.97” 1.97” 1.97” 1.57” X
X
X
X
X
X
X
To
tal Vertical
Ve
nt Ri
se
27’
1.97” 1.97” 1.97” 1.97” 1.57” X
X
X
X
X
X
X
24’
1.97” 1.97” 1.97” 1.97” 1.57” 1.18” X
X
X
X
X
X
21’
1.97” 1.97” 1.97” 1.97” 1.57” 1.18”
0
X
X
X
X
X
18’
1.97” 1.97” 1.97” 1.57” 1.57” 1.18” 0.79”
0
X
X
X
X
15’
1.57” 1.57” 1.57” 1.57” 1.18” 1.18” 0.79”
0 0
X
X
X
12’
1.57” 1.57” 1.57” 1.18” 1.18” 0.79”
0 0 0
X
X
X
9’
1.57” 1.57” 1.18” 1.18” 0.79”
0 0 0 0
X
X
X
6’
1.18” 1.18” 0.79” 0.79”
0 0 0 0 0
X
X
X
3’
0 0 0 0 0 0 0 0
X
X
X
X
0’
0 0 0 0 0
X
X
X
X
X
X
X
0’ 3’ 6’ 9’ 12’ 15’
18’ 21’
24’ 27’
30’ 33’
Horizontal Vent Run
Содержание Space Creator 120
Страница 26: ...26 Air Intake for a Platform NOTE Please refer to the Platform section for details on platform construction ...
Страница 38: ...38 Examples using a 110 Front ...
Страница 55: ...55 Wiring Diagram Screen Fireplace with Interior Lighting ...
Страница 56: ...56 Wiring Diagram Double Glass Fireplace ...
Страница 57: ...57 Wiring Diagram Double Glass Fireplace with Interior Lighting ...