Step-by-Step Chase Construction 

The following checklist is a simplified overview of typical chase construction for a 60HH series fireplace installation. This list is not 

exhaustive and does not supplement thorough review of the installation manual. 

Step 1 

BUILD BACK AND SIDE WALLS 

  Frame the back and side walls according to framing requirements. 

  Build the platform (if necessary) to the desired height and install inside fireplace chase.  

  Platform must be stable and able to bear the full weight of the fireplace. Platform can be constructed out of wood, concrete, 

metal, or any other solid materials. Material is not required to be non-combustible.  

Step 2 

INSTALL FIREPLACE AND VENTING, RUN GAS AND ELECTRICAL 

  Install the fireplace and venting. This must be completed by an authorized Ortal dealer (unless otherwise authorized by Ortal 

with written approval). 

  Move the gas valve and receiver unit to the designated access panel location. If the fireplace will not have an access panel, 

keep gas valve and receiver unit directly underneath the fireplace. 

  Run gas and electric to the gas valve and receiver unit location. 

Step 3 

BUILD FRONT WALL 

  Install front chase wall: 

  Build front wall according to framing requirements. 

  Stand up the front wall and move into place. 

  Secure front wall to the rest of the chase structure. 

  Cover the exterior of each wall (sides, front, and back, as applicable to your design) with 

5

/

8

” Type X Drywall (or equivalent) 

and seal gaps with a non-combustible fire sealant. 

 NOTE: 

5

/

8

” Type X Drywall (or equivalent) is not required on the exterior portion of an insulated outside-facing wall. 

  Check to make sure constructed chase meets the requirements for heat release and air intake. 

Step 4 

APPLY FINISHES 

  Apply finishes and install accessories, following all clearances and building requirements. 

  Ensure furniture and other combustible materials maintain a minimum 40 inches of clearance directly in front of the fireplace 

viewing area for both front and side viewing areas (as applicable). 

 

Содержание 60HH Corner LS

Страница 1: ...Ortal Installation Manual 60HH Series V1 0 Installation and Operation Manual Ortal 60HH Series Ortal 60HH Series Fireplaces 60HH Front Facing 60HH Corner RS LS 60HH Three Sided TS...

Страница 2: ...fireplace and shall be installed The fireplace MUST not be used without the heat barrier in place If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this...

Страница 3: ...Platform 11 Framing Dimensions 12 General Clearances 15 Heat Release 16 Air Intake Opening 18 Mounting a TV Artwork 20 Access Panel 22 Chase Area Minimum 22 Recessed Ledge Detail 23 Structural Weight...

Страница 4: ...Media Placement 45 Operation 46 10 Button Remote Control Handset 46 Operating Instructions 46 Puck Handset 47 Operating Instructions 48 Wall Switch 49 Operating Instructions 49 MyFire App 50 Operatin...

Страница 5: ...as an Accredited Standards Developer Certification Standard US ANSI Z21 88 2019 Vented Gas Fireplace Heaters Canada CSA 2 33 2019 Vented Gas Fireplace Heaters Products CLASS 2901 84 DOMESTIC HEATERS...

Страница 6: ...an area easily accessible by the owner typically near the access panel if available You must instruct the owner before handing over the fireplace where this label can be found OWNERS Make sure the in...

Страница 7: ...irflow inside the chase These stand offs can directly touch combustible framing Top Framing Stand offs Attached to the front top portion of the fireplace above the glass viewing area It keeps a cleara...

Страница 8: ...ult with the contractor and go over all requirements Chase framing requirements 5 8 Type X Drywall or equivalent requirements Heat release requirements Air Intake requirements Access panel size and lo...

Страница 9: ...d safety barrier Review operation of the fireplace and remote control with the owner Set up return visit to clean glass after the Initial Burning Period see Post Installation section below Post Instal...

Страница 10: ...has no limit No material is permitted to extend past the metal lip surrounding the fireplace viewing area 5 8 Type X Drywall Requirements One layer of 5 8 Type X Drywall or equivalent must be install...

Страница 11: ...8 Type X Drywall or equivalent Chase interior does not require a layer of 5 8 Type X Drywall This applies to both combustible and non combustible framing NOTE 5 8 DensGlass Fireguard Sheathing is an a...

Страница 12: ...the only permitted application The fireplace may be recessed into the wall Refer to diagrams and values below and in the following pages for details 60HH Front F Series Fireplace A Height B Length C...

Страница 13: ...C Depth D Stand Off E Legs F Glass Length G Glass Height 60HH RS LS 49 1 2 67 1 2 21 5 8 10 7 16 9 13 16 61 5 16 29 1 2 Framing Fireplace 60HH RS LS A Height 49 1 2 B Length 67 1 2 C Depth 21 5 8 V Fi...

Страница 14: ...gth C Depth D Stand Off E Legs F Glass Length G Glass Height 60HH TS 49 1 2 65 1 2 21 5 8 10 7 16 9 13 16 64 3 16 29 1 2 Framing Fireplace 60HH TS A Height 49 1 2 B Length 65 1 2 C Depth 21 5 8 V Fire...

Страница 15: ...g area at a 90 angle Building Material The temperature on the side wall can get as high as 150 F above ambient temperature While the fireplace certification allows for this temperature variance buildi...

Страница 16: ...es only the height of the heat release must not exceed 1 3 of the width This does not apply to vertical heat releases The space the heat release vents into must have a minimum volume of 184 ft3 The he...

Страница 17: ...elease is oriented vertically Entire heat release is on one side of the fireplace chase Split Front Vertical Heat Release Full Vertical Heat Release on One Side Sprinkler Clearance to Heat Release In...

Страница 18: ...finished in the form of a louvered ventilation grille gap or toe kick reveal For louvered ventilation grilles the net free air space allowed in the louvered area must be equal or greater than the min...

Страница 19: ...19 Air Intake for a Platform NOTE Please refer to the Chase Floor Platform section on page 11 for details on platform construction...

Страница 20: ...information Wires inside the chase are not permitted to cross over the fireplace Wires must be installed against a wall The decision to install a television above an Ortal fireplace is up to the disc...

Страница 21: ...he TV is mounted on a wall that recesses over fireplace the TV must be at least 12 inches from the top of the fireplace glass viewing area NOTE Vent clearances must be maintained See Vent Clearances s...

Страница 22: ...r design media and lifting the grill burner and bottom pressure release valve This will increase service time and difficulty An access panel is always preferred Fireplace dealers installers are advise...

Страница 23: ...ucture must be non combustible framing and finish Ledge Size A x B 410 sq in A ledge depth B ledge width Top View Oversized Ledge If ledge surface area exceeds 410 sq in the heat release must be divid...

Страница 24: ...face Consult with the project structural engineer and refer to your local building codes for proper wall support The following drawing shows a recommended approach to this type of installation Please...

Страница 25: ...e designated access panel location If the fireplace will not have an access panel keep gas valve and receiver unit directly underneath the fireplace Run gas and electric to the gas valve and receiver...

Страница 26: ...fireplace viewing area This area must be unobstructed to allow the heat barrier and inside glass panel to be removable MANUFACTURED STONE A minimum 2 inch recess is suggested Consult stone manufacture...

Страница 27: ...epth is measured from the edge of the fireplace lip to the out most part of the wall including finish material Side overhang has no limit Finish material on the underside of the overhang may be combus...

Страница 28: ...Vent System Selkirk Direct Temp System Enervex RS Power Vent optional Ortal Power Vent optional 3x5 co axial direct vent pipe 3 interior 5 exterior DuraVent CVS line Power Vent a fan assisted direct...

Страница 29: ...a 90 elbow that stays in the horizontal plane 6 feet must be reduced from the total allowable horizontal run Up to two flat elbows are allowed Example If max allowable horizontal run is 24 feet and 1...

Страница 30: ...Allowable Maximum Horizontal Runs 60HH Series 135 Single Burner V minimum 3 feet Vertical V Max Horizontal H 3 ft 9 ft 6 ft 18 ft 9 ft 30 ft 12 ft 30 ft 15 ft 30 ft 18 ft 30 ft 21 ft 27 ft 24 ft 24 f...

Страница 31: ...ries V Minimum 3 Feet Total Vertical Vent Rise 44 2 75 X X X X X X X X X X X 42 2 75 2 75 2 75 1 97 X X X X X X X X 39 2 75 2 75 2 75 1 97 X X X X X X X X 36 2 75 2 75 2 75 1 97 X X X X X X X X 33 2 7...

Страница 32: ...and sof ts 1 There must be 3 feet minimum between termination caps 2 All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap 3 All gravity...

Страница 33: ...Alcove height Q US Canada See table below Alcove width dependent on number of caps in the space R US Canada See table below Alcove depth dependent on number of caps in the space Vent Caps QMINIMUM RM...

Страница 34: ...does not apply to a chimney shroud application See the Chimney Shroud section on the next page for more information TERMINATION CAP NOTE A Low Profile Termination Cap can negatively impact flame appe...

Страница 35: ...d to the fireplace starter collar with a minimum of 3 sheet metal screws no longer than DO NOT use silicone to seal the sections If sealing is required by the vent manufacturer or local code use Mil P...

Страница 36: ...sibly death Co linear flexible aluminum venting must be professionally inspected periodically for corrosion and damage and replaced when necessary If the installation does not allow for future inspect...

Страница 37: ...Rise 40 feet see diagram below Offsets Two 45 offsets may be used directly on the fireplace with up to a 6 foot section between them The minimum vertical rise starts above them see diagram below No o...

Страница 38: ...components are attached to the pilot on a flexible gas line and can be kept directly under the fireplace or depending on the model moved to the left right or back of the fireplace within 36 inches of...

Страница 39: ...s following the figure Part Number Description Part Number Description ASB001 Pilot Bracket ASB002 Pilot Gasket D23 Orifice LPG G13 Electrode Target Type D36 Orifice NG G121 Main Burner Gas Fitting G0...

Страница 40: ...cy 1 Press and hold the receiver s reset button until you hear two beeps The first beep is short and the second beep is long After the second beep release the reset button 2 Within the subsequent 20 s...

Страница 41: ...quired for different feature combinations For wiring diagrams with Ortal or Enervex power vent refer to the applicable power vent manual For wiring diagrams with CO shutoff kit refer to CO Shutoff Kit...

Страница 42: ...42 Wiring Diagram Double Glass Fireplace with Interior Lighting...

Страница 43: ...ems only and will not connect the fireplace to a wireless system Interior Design Media Ortal offers interior media options such as stones glass logs and embers that can be provided with the fireplace...

Страница 44: ...l injury Do not use the hood to support media This could cause overheating of the thermocouple Keep the media away from the edges and the glass Do not overfill the media tray Keep 20 of the tray open...

Страница 45: ...me from creating soot on the media or to manipulate the look of the flame Block as few ports as possible and no more than 30 of total ports Do NOT block ports that are next to one another When combini...

Страница 46: ...therefore will not operate during a power failure Only the Mertik Maxitrol AC Adapter is permitted for use with the fireplace Use of other adapter brands can render the system inoperable The handsets...

Страница 47: ...o turn the fireplace off NOTE The fireplace may be turned on again after the OFF icon stops flashing Flame Height Adjustment 1 To increase flame height press and hold the button to desired flame heigh...

Страница 48: ...rease Flame Height INCREASE To increase flame height press and hold button DECREASE To decrease flame height press and hold button Holding the button long enough sets the fireplace to pilot flame Stan...

Страница 49: ...ight Adjustment INCREASE To increase flame height press and hold up flame button DECREASE To decrease flame height press and hold down flame button Holding the down flame button long enough sets the f...

Страница 50: ...up and operating instructions of the MyFire app see the Homeowner s Fireplace Operation Manual or visit the Ortal website or www myfireapp com MyFire Wi Fi Box The MyFire Wi Fi router box provides the...

Страница 51: ...out the glass properly securely in place Only an Ortal certified installer is authorized to remove the glass Glass must be removed using an 8 inch glass handling suction cup Lower the glass to rest in...

Страница 52: ...Ortal 2022 Version 1 0 August 2022 SKU KPMAN60HHNLUSV1 0 Ortal USA 2152 Citygate Drive Columbus OH 43219 T 818 238 7000 F 818 678 0541 info ortalheat com www ortalheat com...

Отзывы: