Operator's manual
Ch
ap
ter
:
Di
ag
no
st
ic
s
27
ERROR: Cod. 11 Vcap low 1
Problem:
The voltage on the first bank of capacitors has not reached the required value or is not charged.
Solution:
Check the electrical system.
Ensure the correct operating voltage.
Contact technical support.
ERROR: Cod. 12 Vcap High 1
Problem:
The voltage on the first bank of capacitors has reached its limit.
Solution:
Check the electrical system.
Ensure the correct operating voltage.
Contact technical support.
WARNING: Cod. 13 IMS hot 1
Problem:
The temperature of the first IMS circuit for the flash guide lamp is too high.
Solution:
Wait for the device to automatically return to normal, do not turn off the device.
Check that the vents are open and not blocked.
Check the condition of side filters and clean or replace if necessary.
If automatic recovery does not happen, contact technical support.
ERROR: Cod. 14 Precharge 2
Problem:
The second circuit of the pre-charging of the capacitors does not activate.
Solution:
Check the electrical system.
Make sure there are no problems with the electricity.
Ensure the correct operating voltage.
Contact technical support.
WARNING: Cod. 15 IMS hot 2
Problem:
The temperature of the second IMS circuit for the flash guide lamp is too high.
Solution:
Wait for the device to automatically return to normal, do not turn off the device.
Check that the vents are open and not blocked.
Check the condition of side filters and clean or replace if necessary.
If automatic recovery does not happen, contact technical support.
ERROR: Cod. 16 Vcap High 2
Problem:
The voltage on the second bank of capacitors has reached its limit.
Solution:
Check the electrical system.
Ensure the correct operating voltage.
Contact technical support.
ERROR: Cod. 17 Vcap low 2
Problem:
The voltage on the second bank of capacitors has not reached the required value or is not charged.
Solution:
Check the electrical system.
Ensure the correct operating voltage.
Contact technical support.
WARNING: Cod. 18 CCPS Hot 2
Problem:
The temperature of the electronic circuits for the second lamp is too high.
Solution:
Wait for the device to automatically return to normal; do not turn it off, leave it on to speed up the cooling
process.
Check that the vents are open and not blocked.
Check the condition of side filters and clean or replace if necessary.
If automatic recovery does not happen, contact technical support.
ERROR: Cod. 19 Simmer 2
Problem:
The firing circuit of the second lamp is not working or the lamp does not light.
Solution:
Contact technical support.
ERROR: Cod. 20 COM fail
Problem:
There is no communication between the internal circuit boards.
Solution:
Contact technical support.
ERROR: Cod. 21 Syncronizing
Problem:
There is a problem with the synchronization signal between the circuit boards.
Solution:
Wait for the device to automatically return to normal, do not turn off the device.
If automatic recovery does not happen, contact technical support.