Resetting Reference Priorities to Factory Defaults
To reset all references in the
Reference Priority
table to their factory default priorities:
1.
Navigate to the
Configure Reference Priorities
screen via
MANAGEMENT >
OTHER: Reference Priority
menu.
2.
In the
Actions
panel, click the
Restore Factory Defaults
button.
3.3.1.2 The "Local System" Reference
The
Local System
reference is a "Self" reference, i.e. VelaSync uses itself as an input ref-
erence for Time, or as a 1PPS reference. The
Local System
is a unique input reference in
that it can be used as either the Time reference, or the 1PPS reference,
but never both
.
Note:
For VelaSync to operate as a
Local System
reference, you must have
either a valid external Time reference, or a valid external 1PPS reference.
3.3 Managing References
CHAPTER
3
•
VelaSync 1232 User Manual Rev. 4
115