7
TECHNICAL DATA
Nominal voltage:
12V DC
±10%
Number of users:
2000
Card reading distance:
Max. 4cm
Power consumption during operation:
≤
150mA
Power consumption at stand-by:
<25mA
Load on door relay:
<1A
Load on the alarm output:
<1A
Permissible operating temperature:
-45
°C÷+
55
°C
Permissible humidity:
0%
÷
95% RH
Ingress protection:
Compliant with IP68
Output activation time adjustment (electric door strike):
0-99 seconds
Type of RFID cards:
EM 125kHz Unique
Wiegand Interface:
Wiegand 26 bits
Wiring connection:
Electric door strike, exit button, external alarm, external reader
Dimensions:
70x140x24mm
INSTALLATION
1. Remove the back cover from the keypad using the supplied allen key.
2. Drill two holes on the wall for the self-taping screws and one hole for the cable.
3. Put the supplied plastic anchors into two holes.
4. Fix the back cover firmly on the wall with two self-taping screws.
5. Put the cable through the cable hole.
6. Attach the device to the back cover.
FEATURES
•
Waterproof, compliant with IP66
•
Robust and resistant zinc alloy housing with protective coating
•
Full keypad programming possible
•
Memory for 2000 users
•
Can be used as a separate keypad
•
Backlit keypad
•
EM 125kHz proximity card and tag reader
•
Wiegand 26 type input for connection to an external reader
•
Wiegand 26 type output for connection to the controller
•
Adjustment of the door strike opening time
•
Short-circuit protection of the electric striker
•
Easy installation and programming
•
Tri-color LED status display
•
Built-in buzzer
Programming mode - Quick guide
Administrator settings
Change the main code
* Main code #
00
New code # New code #
The main code may contain from 6 to 8 digits. Factory setting: 999 999
Entering the administrator "add card"
01
Read Add Card. Factory setting: zone 1
Entering the administrator "delete card"
02
Read Delete Card
Delete all users
07
0000 #
Opening of lock 1 by the administrator
51
Opening of lock 2 by the administrator
52
User settings
–
Zone 1
Adding card user
* Main code #
11
Read card # or
User ID number # Read card # or
Input card number # or
User ID number # Input card number #
Adding PIN user
* Main code #
11
User ID number # PIN code #
Users can be added consecutively without having to exit from the programming
mode.
Delete users
12
Read card # or
User ID number # or
Input card number #
Users can be deleted consecutively without having to exit from the programming
mode.
Access settings
Card access
* Main code #
13
0 # (factory setting: card reading or pin code input)
Card + PIN code access
1 # (factory setting: card reading or pin code input)