Orno OR-ZS-805 Скачать руководство пользователя страница 12

12

C) Deletion Mode 3 – Delete one group of user cards (Group clearing):

2) Press BELL button to select deletion mode 3.

....

Response

 :  LED 3 is ON. After 2 seconds, the system confirms the selection with 2 beeps and 

.........................

then the 5 LEDs flashing for five storage groups available.

3) Press BELL button to select the storage group 1-5 for group clearing. 

....

Response

 : The selected LED is ON. After 2 seconds, the system confirms the selection with 2 

.........................

beeps.

4) Press BELL button again to execute group clearing.

....

Response

 : The group LED flashes during clearing and 2 Beeps confirm clearing done.

....

Note:

 

Repeat procedure (3) & (4) for clearing of other storage groups if required.

5) Read Master Card 1 Time to exit Programming Mode.

....

Response

 : 2 Beeps confirm reader back to normal operation.

Remark

:

After Group Clearing, it is necessary to re-store all the existing (not lost) User Cards back to the 

Storage Group one by one with the procedures stated in the “

Record User Cards – The Feature 

Group 1

” section.

Exit

Programming Mode

Group Clearing

 Execution

4

Select Group 1-5

 for Clearing

Select

Deletion Mode 3

Read Master Card 2 Times

Set System in Feature Group 2

5

3

2

1

4) Read Master Card 1 Time to close Programming Mode.

IIII

Response

 : 

2 Beeps confirm reader back to normal operation.

IIII

Note

:

IIII

There is a slot left at the memory stack after a card is deleted. In programming, the new cards will 

IIII

fill in the slots first according to their position in the queue of the memory stack. After all the slots 

IIII

are filled, then the cards will go to the vacancies available at the end of the list.

B) Output Mode 2 – Timing 1 to 60 seconds:

2) Press BELL button to select output mode 2.

....

Response : 

LED 2 is ON. After 2 seconds, the system confirms the selection with 2 beeps.

 

3) Press BELL button once to start the time counting.

....

Response

 : 

Counting from 1 second to 60 seconds with 1 second and 1 short Beep per step. The 

........................

5 indicator LEDs act as timer indicator from 1 to 5 seconds in the 1st round counting, 

........................

and 6 to 10 seconds in the 2nd round ….. and so on, until 60 seconds.

4) Press BELL button again to stop the counting when the desired time reaches. 

....

Response

 :

 2 Beeps confirms the time and the counting LED stops at its position

....

Note

: If it is not the time desired, repeat procedures 

(3)

 & 

(4)

 for a new counting.

5) Read Master Card 1 Time to exit Programming Mode.

....

Response

 : 

2 Beeps confirm reader back to normal operation.

13

Exit

Programming Mode

Stop

Time Counting

Start

Time Counting

Select

Output Mode 2

Read Master Card 3 Times

Set System in Feature Group 3

5

4

3

2

1

3) Read Master Card 1 Time to exit Programming Mode.

....

Response

 : 

2 Beeps confirm reader back to normal operation.

A) Output Mode 1 – Start / Stop (Toggle):

2) Press BELL button to select output mode 1.

....

Response

 : 

 LED 1 is ON. After 2 seconds, the system confirms the selection with 2 beeps.

Exit

Programming Mode

Select

Output Mode 1

Read Master Card 3 Times

Set System in Feature Group 3

3

2

1

III ) SET OUTPUT MODE FOR DOOR LOCK -- Feature Group 3

The operation of the door lock output can be set to Start/Stop mode or 1 second to 60 seconds 

Timing Mode. The ex-factory setting is 2 seconds.

                                   

Output Mode 1

 – Start / Stop (Toggle)

                                   

Output Mode 2

 – Timing 1 to 60 seconds (Door lock striking time)

Procedures

1) Read Master Card 3 Times to set system to Feature Group 3 – Set Output Mode for Door 

....

Lock.

....

Response

 : 

Status LED (blue) starts to flash during programming mode and group LED 3 is ON.

........................

After 2 seconds, the system confirms the selection with 2 beeps and the group LED 

........................

1 & 2 flashing for the two output modes available.

5. Paul

4.    --    (Slot)

4. Alan

3.    --    (Slot)

3. Nancy

2. Tracy

2. Tracy

1. John

1. John

After

Before

5. Paul

6.

  

 --    (Vacancy)

6.

   

--    (Vacancy)

Example

:  An User list before and after deleting Nancy and Alan’s user cards, there are 2 slots (3 

.................

& 4) left.

This is the programming manner of putting three new user cards into 

the system with slots, the 1st one goes to the 1st slot (#3), the 2nd one 

goes to the 2nd slot (#4) and the 3rd one goes to the vacancy (#6) 

available at the end of the list.

Содержание OR-ZS-805

Страница 1: ...device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can...

Страница 2: ...ter Card Procedures of Creating A New Master Card with CMC Jumper PROGRAMMING 1 Criteria for Setting System to Programming Mode 2 Use The Master Card to Set System into Programming Mode for The 5 Feat...

Страница 3: ...om Inside Data I O Bus for Optional Card Readers AR 2802 Accommodates 3 Optional Readers Max Bell Button Output Relay Contact for Actuating An Optional Door Chime Output Contact Ratings iiiia Solid St...

Страница 4: ...a Multi station System with the optional auxiliary reader AR 2802 Maximum three optional readers can be allowed and the connection is very simple Just connect the devices in parallel with the Data I...

Страница 5: ...n worst case even burn out the reader FRONT COVER BACK COVER Fix it on wall HEX SOCKET SCREW 20 1 Stand Alone Access Control Electric Lock NOTE Connect the 1N4004 as close as possible to the lock in p...

Страница 6: ...eader 3 12V Power Supply for The Lock A supply point for the electric lock which is common to terminal 1 4 Power Supply for The Lock Output Contact for Door Lock Strike A 3 Amp rating solid state swit...

Страница 7: ...o Confirm Option 1 3 Auto Confirm Mode 2 Timing Stop Time Counting Start Time Counting Auto Confirm Mode 1 Start Stop FEATURE SETTING PROCEDURES SUMMARY CHART II DELETE USER CARDS I RECORD USER CARDS...

Страница 8: ...ne minute It is necessary to repeat procedures 1 6 and try again CMC JUMPER CMC 2 OFF 1 ON 1 Read User Card to Open Door Read User Card once Two beeps confirm success of reading a valid user card and...

Страница 9: ...rd 4 Audible Indications in Programming Operation 1 Beep Step jumping in feature selection 2 Beeps Execution successful 5 Beeps Execution failed 1 Long Beeps Rejection to a repeated card in programmin...

Страница 10: ...close of programming mode All the User Cards must be unique in the system Repeat recording of same card into other groups will be rejected One long beep indicates rejection of a repeated card Exit Pr...

Страница 11: ...Response Status LED blue starts to flash during programming mode and group LED 4 is ON After 2 seconds the system confirms the selection with 2 beeps and the group LED 1 2 3 flashing for the three op...

Страница 12: ...ndicator LEDs act as timer indicator from 1 to 5 seconds in the 1st round counting and 6 to 10 seconds in the 2nd round and so on until 60 seconds 4 Press BELL button again to stop the counting when t...

Отзывы: