Procedures
1) Read Master Card 1 Time to set system to Feature Group 1 – Record User Cards.
....
Response
:
Status LED (blue)starts to flash during programming mode and group LED 1 is ON.
........................
After 2 seconds, the system confirms the selection with 2 beeps and the 5 group
........................
LEDs flashing for five storage groups available.
2) Press BELL button to select one of the 5 Storage Groups for storing the User Cards.
....
Response
:
The selected group LED is ON for vacancy available. After 2 seconds the system
........................
confirms the selection with 2 beeps.
........................
The selected group LED stays flashing for vacancy full without confirmation.
3) Record the User Cards
....
They can be read and appended one by one into the desired Storage Group.
....
Response
:
2 Beeps confirm successful for each card recording.
4) Read Master Card 1 Time to exit Programming Mode.
....
Response
:
2 Beeps confirm reader back to normal operation.
NOTE:
●
Press BELL button to select other Storage Groups with the above procedures 2 & 3 before close
...
of programming mode.
●
All the User Cards must be unique in the system. Repeat recording of same card into other
...
groups will be rejected. One long beep indicates rejection of a repeated card.
2)
Press BELL button to select deletion mode 1.
....
Response
:
LED 1 is ON. After 2 seconds, the system confirms the selection with 2 beeps.
3)
Read the un-used card(s).
....
They can be read and appended one by one to delete from the system.
....
Response
:
The card’s Storage Group LED lights up for 1 second and 2 Beeps are generated for
........................
each card deletion.
4) Read Master Card 1 Time to exit Programming Mode.
....
Response
:
2 Beeps confirm reader back to normal operation.
A) Deletion Mode 1 – Delete un-used card:
Exit
Programming Mode
Delete
Un-used Cards
Select
Deletion Mode 1
Read Master Card 2 Times
Set System in Feature Group 2
4
3
2
1
14
IV ) SET SYSTEM SAFETY LOCK-UP -- Feature Group 4
The reader can be protected with safety lock-up to prevent trials with un-recorded cards. There are
three options for owner’s selection. Only one option can be selected in programming.
Option 1
-- No lock-up function at all (ex-factory setting)
Option 2
-- Lock-up during 60 seconds after 10 false trials
Option 3
-- Lock-up during 15 minutes after 10 false trials
Procedures -- Options 1, 2 or 3
2)
Press BELL button to select the desired option 1, 2 or 3.
....
Response
:
The LED of the desired option is ON. After 2 seconds, the system confirms the
.........................
selection with 2 beeps.
3)
Read Master Card 1 Time to exit Programming Mode.
....
Response
:
2 Beeps confirm reader back to normal operation.
....
Note:
The system counts each successive trial within 30 seconds and it resets if no reading of
..............
card.
1)
Read Master Card 4 Times to set system to Feature Group 4 – Set System Safety Lock-up.
....
Response
:
Status LED (blue) starts to flash during programming mode and group LED 4 is ON.
........................
After 2 seconds, the system confirms the selection with 2 beeps and the group LED
........................
1, 2 & 3 flashing for the three options available.
Exit
Programming Mode
Select
Option 1, 2 or 3
Read Master Card 4 Times
Set System in Feature Group 4
3
2
1
II ) DELETE USER CARD(S) – Feature Group 2
The User Card(s) can be removed from the system if it is not used or lost. Three deletion modes
are available.
Deletion Mode 1
– Delete un-used card
Deletion Mode 2
– Delete lost card
Deletion Mode 3
– Delete a group of cards (Group clearing)
Procedures
1)
Read Master Card 2 Times to set system to Feature Group 2 – Delete User Card(s).
....
Response
:
Status LED (blue) starts to flash during programming mode and group LED 2 is ON.
........................
After 2 seconds, the system confirms the selection with 2 beeps and the group LED
........................
1, 2 & 3 flashing for the three deletion modes available.
B) Deletion Mode 2 – Delete lost user card:
2)
Press BELL button to select deletion mode 2.
IIII
Response
: LED 2 is ON. After 2 seconds, the system confirms the selection with 2 beeps.
3) Read the user card that the lost card followed.
IIII
Example, the lost user card is #4, then, read the user card of #3 to delete it. Delete other lost
IIII
cards one by one in the same manner.
IIII
Continuous reading of user card #3 will also delete the succeeding user cards # 5, 6, 7 -- etc. As
IIII
card #5 becomes the succeeding card of #3 after deleting #4, and so on.
IIII
Response
: The LED of the lost card’s storage group lights up for 1 second and 2 Beeps are
IIIIIIIIIIIIIIIIIIIIIIIII
generated for each card deletion.
IIII
Remark:
IIII
For the lost user card of number 1 in its group and has no user card in front of it, then read the
IIII
Super User
card of its group to delete it. The 5 user groups each one has its Super User card.
IIII
See Create Super Cards in page 15 for the details.
Exit
Programming Mode
Delete
Lost Cards
Select
Deletion Mode 2
Read Master Card 2 Times
Set System in Feature Group 2
4
3
2
1
11