3. Troubleshooting

Symptom

Reason

Action

Hot air blower 

cannot reach set 

temperature

Wrong lightning up

Check. 5.1 „Lightning up”

Too humid wood

Humidity control – use wood with proper 

parameters

Clogged primary air channels

Call service – after warranty service

Clogged secondary air pipes

Call service – after warranty service

Polluted heat exchanger’s pipes

Clean with round tool or call service - after 

warranty service

Unproper mix of air with wood 

gases

Call service – after warranty service

Damaged nozzle

Replace – after warranty service

Smoking from fan gasket

Replace – after warranty service

Damaged fan

Replace – after warranty service

Smoking from heat 

exchanger lid

damaged rope

Screw in lid tightly, replace rope or call service

hardened rope

Replace rope - after warranty service

Damaged heat exchanger's lid

Replace lid - call service

Smoking from 

loading door

Strong wind force exhaust gases 

into the chimney

Consider installation of appliances supporting 

chimney draft (WKO)

Unproper chimney parameters

Rebuild chimney, chimneys weeper assistance

Smoking from door Leakiness from door

Door adjustment according to 5.2.

Used rope - leak

Rope replacement or call service - after warranty 

service

Damaged door

Door replacement

Controller doesn’t 

work

No voltage in the grid

Check electric installation

Damaged fuse

Fuse replacement

Damaged wire

Wire control or replacement

Damaged boiler sensor

Call service

Damaged controller

Call service

Fan doesn’t work

Damaged fan

Fan replacement – call service

Fan blades blocked

Check and clean fan

Loud work of fan

Damaged bearings

Call service- fan replacement

Damaged condenser

Call service – condenser replacement

Loosen fixing of fan

Fixing control, screw in

Polluted fan blades

Control, cleaning

Pitch in fan casing

Control, cleaning

Содержание Orligno 600

Страница 1: ...ORLIGNO 600 INSTRUCTION MANUAL SERVICE MANUAL HOT AIR BLOWER...

Страница 2: ...parameters setting and lightning up 4 4 4 Service mode OPERATION PARAMETERS 6 4 5 Service mode LANGUAGE 9 4 6 Service mode TEST 10 4 7 Service mode SERVICE SETTINGS 10 4 8 Room temperature controller...

Страница 3: ...it for every purposes Controller protects boiler against overheating with blow fan turning off and back fan activation 2 Principle of work Gasification boilers utilize process of dry pyrolitic wood di...

Страница 4: ...ORLIGNO 600 hot air blower is delivered fully assembled attached with screws to pallet and wrapped in foil ORLIGNO 600 comes with set of cleaning tools 3 pcs and documentation manual warranty card an...

Страница 5: ...N The fuses should be replaced with the controller switched off and unplugged 4 2 Controller switch on Turn on the controller using on off switch The display should show the name of the controller and...

Страница 6: ...the HI parameter 6 4 4 Service mode OPERATION PARAMETERS Fan hysteresis This parameter shows how much the temperature must fall from set temperature to turn the fan on Temperature setting range 0 C t...

Страница 7: ...modulation is limited to hysteresis i e it works within the range of set boiler temperature and set hysteresis parameter Below hysteresis the fan works with maximum set power Maximal fan power control...

Страница 8: ...0 C to 120 C Extinguish time control This parameter allows for setting the fan operation extinguish when the temperature on the sensor falls down to 30 C Setting range 0 45 minutes Blow through operat...

Страница 9: ...set by the HI parameter ATTENTION Setting the operation time for 0 will turn off the blow through function Fan pause stoking Parameter setting the fan pause time necessary for stoking the boiler Time...

Страница 10: ...on representing individual device fan heater By pressing or buttons individual devices are turned on off 4 7 Service mode SERVICE SETTINGS This function cancels all settings entered by the user and re...

Страница 11: ...ocket 4 9 Temperature sensor damage If the temperature sensor is damaged the controller will STOP and will appear on the display instead of the temperature The red diode FAILURE will be on It is possi...

Страница 12: ...C to 9 C Heater hysteresis 10 C Blow through control work time 0 90 sec pause 1 60 min Controllable boiler extinguishing time 0 45 min Input power fan 100 VA 230 V heater 100 VA 230 V Voltage AC 230...

Страница 13: ...lity moisturecontentandtypeofburned wood The best is hardwood beech oak harnbeam with moisture content 15 20 Lenght of wood should be the same as depth of loading chamber Usage other types of wood lik...

Страница 14: ...le stoking the hot air blower Wood dimensions larger than recommended may cause troubles during closing the upper door It is necessary to avoid closing upper door with force it may damage the door ATT...

Страница 15: ...ter burning softwood leave the boiler open in this way damp is not condensing on the sides of boiler ATTENTION It is advisable to control the hot air blower annually in order to prepare it well for th...

Страница 16: ...exchangers lid 3 Clean each of pipes with round tools moving it up and down Ash created during wood burning falls down through the nozzle to ash chamber that s why it is advisable to remove the ash f...

Страница 17: ...17 1 2 3...

Страница 18: ...ptable to clean the fan blades with brush with soft bristle or vacuum cleaner Cleaning of both fans should be done at least once a year after or before heating season blocking nut 6 2 Hot air blower t...

Страница 19: ...tilation 20 1 4 Hot air blower connection to chimney system 20 2 Technical data 22 2 1 EKOSTER 3 technical data 22 2 2 EKOSTER 3 installation recommendations 22 2 3 Technical data of heater 23 2 4 Ele...

Страница 20: ...s in which the hot air blower is sold 1 Boiler room height should be at least 2 2 m for easier boiler cleaning 2 Distance from boiler room walls should allow for free access to boiler sides and should...

Страница 21: ...f non inflammable material 1 3 Exhaust ventilation 1 Exhaust duct should be made of bricks with section of at least 25 of chimney section not less 14 x 14 cm Inlet hole cannot have any devices that re...

Страница 22: ...ll draft regulator which stabilizes chimney draft and in case too big underpressure in chimney opens up and sucks in air from boiler room instead of hot air blower Pic 2 Stainless steel double wall ch...

Страница 23: ...ed to check controller s settings before lightning up 8 Controller is equipped with two 1 25 A fuses Temperature range from 58 C to 390 C Boiler temperature settings from 50 C to 120 C Heater temperat...

Страница 24: ...or fuses replacement 8 7 T1 L N N N L L room thermostat hot air sensor ground front fan live heater live 230 power supply live front fan neutral heater neutral 230 power supply neutral T1 L N N N L L...

Страница 25: ...thermostat hot air sensor ground front fan live heater live 230 power supply live front fan neutral heater neutral 230 power supply neutral contactor s coil working contacts of contactor heater front...

Страница 26: ...26 2 5 Dimensions...

Страница 27: ...lower 1 Hot air outlet 2 Hot air controller 3 Loading door 4 Front fan 5 Combustion door 6 Firebricks 7 Combustion chamber 8 Nozzle 9 Heater 10 Tube heat exchanger 11 Ceramic moulders 12 Loading gasif...

Страница 28: ...d logs lenght cm 50 Humidity recommended 15 25 Fuel usage for power nominal kg h 8 2 Temperatures setting range C 50 120 Protection level of controller IP 40 Voltage Frequency V Hz 230 50 Exhaust gase...

Страница 29: ...aged heat exchanger s lid Replace lid call service Smoking from loading door Strong wind force exhaust gases into the chimney Consider installation of appliances supporting chimney draft WKO Unproper...

Страница 30: ...to reuse electrical and electronic components Symptom Reason Action Weak work of fan Polluted fan blades Control cleaning Fan flap clogged with pitch Clean or call service Explosions in hot air blower...

Страница 31: ...31...

Страница 32: ......

Отзывы: