2. Technical data
2.1. eKOSTeR 3 – technical data
2.2. eKOSTeR 3 – installation recommendations
1. Controller is adjusted to cooperate with solid fuel boilers.
2. Controller must be installed by qualified person.
3. Controller cannot work at temperatures higher than 40°C.
4. Controller should be protected against water flooding and steam condensation.
5. Controller should be installed and used according to handling rules with electric equipment.
6. Fuse burning as a result of wrong pump connection is not considered as a warranty matter.
7. It is recommended to check controller’s settings before lightning up.
8. Controller is equipped with two 1,25 A fuses.
Temperature range
from - 58 °C to + 390 °C
Boiler temperature settings
from + 50 °C to + 120 °C
Heater temperature settings
from + 40 °C to + 120 °C
Smooth blow-through control
yes
Controllable min. fan power
30 - 70 %
Controllable max. fan power
30 - 100 %
Fan hysteresis
from 0 °C to 9 °C
Heater hysteresis
10 °C
Blow-through control
work time: 0 - 90 sec.
pause: 1 - 60 min.
Controllable boiler extinguishing time
0 - 45 minute
Input power
fan: 100 VA / 230 V
heater: 100 VA / 230 V
Voltage AC
230 V, 50 Hz
Electrical protection
2 x 1,25 A
Relative air humidity
< 95 %
Protection class
IP 40
Insulation class
II
Ambient temperature
0 °C to + 40 °C
Software class
A
Operation type
fan: 1Y
heater: 1B