37
13.3. Settings
Description of functions in submenu SETTINGS.
Function
Description
Comfort temperature
Programmed temperature in room during heating.
Program
Programs:
a. time program – according to programmed time- intervals
b. permanent – no matter of time-intervals comfort
temperature is kept
c. off – heating is turned off
d. economic – during all period economic temperature in room
is kept
Economic temperature
Programmed temperature in room after heating period
13.4. Time program
It is for time program configuration that controls central heating.
Settings description of time program can be found in chapter 3.4
13.5. Service
ATTENTION!
Service menu is only for qualified staff. Any settings’ changes may lead to incorrect
system operation.
Description of functions in submenu SERVICE.
Function
Description
Temp. MIN pump comf.
Minimal calculated central heating temperature, at which
pump is ON during comfort period.
Temp. MIN pump. econ.
Minimal calculated central heating temperature, at which
pump is on during economic period
Source
Determines source of energy for central heating
Max. temperature
Maximal calculated temperature for central heating
Mixing valve time
Time when mixing valve is fully opened
H.d.w. priority
H.d.w. priority for given central heating circuit; during h.d.w.
heating, central heating pump doesn’t work
Pump test
Starts circulation pump regardless of outside conditions.
Mixing valve test
Starts mixing valve actuator regardless of outside conditions.
Circuit name
Gives the name for central heating circuit.
Содержание ORLIGNO 100
Страница 1: ...ORLIGNO 100 MANUAL AND SERVICE MANUAL...
Страница 6: ...6 3 1 Dimensions 3 2 Boiler construction...
Страница 7: ...7 3 3 Safety valve connection...
Страница 12: ...12...
Страница 23: ...23 Pic 5 Burner assembly Pic 6 Feeder assembly...
Страница 24: ...5 4 Tank assembly 24...
Страница 47: ...47...