19. Alarms
Menu contains history of maximum 20 alarms, that occured during controller’s work. Meanings of
code alarms is shown below:
Alarm codes and their meaning.
Code
Short description
Description
1
Processor’s overheating
Controller’s processor has been overheated. Improper
controller placement may be one of the reasons.
2
Lack of fl ame/fuel
Controller detected lack of fl ame in burner. Lack of fuel
or fl ame gone out may be one of the reasons.
3
Burner’s overheating
Burner’s temperature has exceeded maximum value
4
Boiler’s sensor short circuit
Controller detected short circuit. Damaged sensor or
connecting wire may be one of the reasons.
5
Boiler’s sensor break
Controller detected gape of boiler sensor. Damaged
sensor or conecting wire may be one of the reasons.
6
Burner’s sensor short circuit
Controller detected gape of sensor. Damaged sensor or
connecting wire may be one of the reasons.
7
Gape of burner’s sensor
Controller detected gape of sensor. Damaged sensor or
connecting wire may be one of the reasons
8
Boiler’s overheating
Boiler’s temperature has exceeded maximum value
9
Processor reset
Possible controller’s damage! Lack of power supply
43