background image

 

© 2007 ORION Technology LTD. All rights reserved.                           

33/40

 

3. If the firmware download fails, it replies the following message. In this 
case, you have to send $ActUpgradeFW again to do it over. 

   $ActUpgradeFW,[Command S/N],FAIL,[RTC Time]& 

(Note: Weak GSM signal or broken image file may cause download 
problems. We recommend you to test and verify the firmware update 
process before mass deployment.) 
 
4. If the firmware update is successful, it replies the following information 
after booting by the new firmware. All configuration will remain the same 
and will not be affected by the new firmware. 

 $ActUpgradeFW,[Command S/N],DONE,<UnitID>,<IMEI>,<IMSI>,<HW 
VER>,<FW VER>,<RTC>&

 

 

 
 

Содержание OBDtrac

Страница 1: ...2007 ORION Technology LTD All rights reserved 1 40 OBDtrac Dongle Getting Started Version 1 01 01 Date 2011 12 12...

Страница 2: ...Basic Configuration 11 III GPRS Connection Configuration 12 IV Gateway Server Configuration 19 V Function Variables Configuration 20 VI Function Variables Configuration Mileage Report 21 VII Function...

Страница 3: ...2007 ORION Technology LTD All rights reserved 3 40 1 OBDtrac Dongle Hardware Introduction I Package contents 1 OBDtrac Dongle x 1 with Li ion backup battery 2 OBDII Port Extension Y Cable Y Cable PHOT...

Страница 4: ...FF Power OFF Flash Power ON GSM OFF GSM module OFF or Error Flash No SIM Card Searching networks 0 25sec ON 0 5sec OFF Flash GSM registered 0 5sec ON 0 5sec OFF Flash GPRS connecting 0 25sec ON 0 25se...

Страница 5: ...over back to its original position Since the GPS module is still being fine tuned there may be position fix issues if the device is plugged directly onto the OBDII port and hidden within the vehicle I...

Страница 6: ...ws ATR seq pw Initial Mileage Example of the ATR command would be ATR 1234 0000 1000 Note 1000 is an example value of initial mileage Once entered the total mileage counter shown in the event reports...

Страница 7: ...e value but also the speed RPM and coolant temperature as well Make sure all the OBD values are correct when the vehicle is stationary before allowing the vehicle to begin its trip Example of LGPS ret...

Страница 8: ...ert SIM card Use the configuration RS 232 cable DB 9 to connect OBDtrac Dongle to a PC COM port 2 Open Hyper Terminal or other terminal program at Windows Start Menu All Programs Accessories Communica...

Страница 9: ...echnology LTD All rights reserved 9 40 4 Set the Baud rate as 115200 bps and Flow control as none Press OK 5 Connect the 10pin cable to OBDtrac 6 Connect the 10pin cable power plug to the AC adapter a...

Страница 10: ...tracker is originally set to vibration power control mode In doing so OBDtrac will enter Debug Mode Configuration Mode Version 0 12 Serial Number BH1234567890 Unit ID 1000000001 IMEI 7 If you do not s...

Страница 11: ...Version 0 7 2 UnitID 1000000001 0000000000 4294967296 3 User Password 0000 5 COM1 Baudrate 38400 115200 38400 19200 9600 4800 7 Sync RTC with GPS Time YES Time Zone of RTC GMT 0 C GPS Fix Timeout 300...

Страница 12: ...off mode 2 standby mode 3 sleep mode 4 deep sleep mode functional only in conjunction with VACCON mode in GSM GPRS connection settings Event Mask 1 Configure event mask bits to enable disable event tr...

Страница 13: ...commands by SMS only All event reports are supported in SMS mode It helps to use the tracker in the area without GPRS coverage Multiple protocol commands and event reports are can be in one SMS as lo...

Страница 14: ...t NO Disable roaming Default Value NO Roaming Profile Setting Set roaming profile configurations and roaming event masks Enable RGTK RMTK YES Generate the latest GPS position and send it as RGTK event...

Страница 15: ...RS Not Ready Re Connect Time sec 300 300 65535 D Protocol TCP TCP UDP F Require Server ACK NO YES NO G Include Cell ID Info in Report NO YES NO H Nonstop GPRS Tracking NO YES NO J Binary Report NO YES...

Страница 16: ...Seconds Set longer Sync Interval to save GPRS cost Note The SYNC packet is now only applicable in STOP mode or when ACC OFF in ACCON mode or VACC mode Resync Interval 5 Compulsory SYNC packet Interva...

Страница 17: ...ime when timeout the tracker will send the event report again The unit is second Range from 5 65535 Retry 5 How many times to retry to send the event report If it keeps failing the tracker will re ope...

Страница 18: ...le binary encryption report mode For more details refer to binary report app note Notes This console menu corresponds to ORION Protocol commands SetGPRSConfig SetConnection 3 When you finish the GPRS...

Страница 19: ...ables Setting 5 Report Settings Setting E Exit Selection 3 Press Enter Gateway Server Setting Menu 1 Primary Gateway Server IP 220 128 135 215 Port 9998 0 65535 E Exit Selection Gateway Server Setting...

Страница 20: ...to enter Function Variables Setting Menu Main Setting Menu 1 Basic Setting 2 GSM GPRS Connection Setting 3 Gateway Server Setting 4 Function Variables Setting 5 Report Settings Setting E Exit Selecti...

Страница 21: ...ction 1 Press Enter Mileage Report Setting Menu 1 Total Mileage mile 0 0000 2 Mileage Limitation mile 0 0000 3 Distance Interval Track mile 0 0000 4 Deviation Angle Track degree 0 0000 E Exit Selectio...

Страница 22: ...turn to Main Setting Menu Then type YES to apply all settings to the Flash Memory Main Setting Menu 1 Basic Setting 2 GSM GPRS Connection Setting 3 Gateway Server Setting 4 Function Variables Setting...

Страница 23: ...eport Setting 5 Speed Limit Report Setting E Exit Selection 4 Press Enter Idle Report Setting Menu 1 Idle Report Enable NO 2 Idle Duration sec 0 3 Report Time Interval sec 1 1 Once 2 65535 E Exit Sele...

Страница 24: ...Report Settings type E to return to Main Setting Menu Then type YES to apply all settings to the Flash Memory Main Setting Menu 1 Basic Setting 2 GSM GPRS Connection Setting 3 Gateway Server Setting...

Страница 25: ...ed Limit Report Setting E Exit Selection 5 Press Enter Speed Limit Report Setting Menu 1 Speed Limit Report Enable NO 2 Speed Limitation mph 0 3 Speed Limitation Duration sec 0 4 Report Time Interval...

Страница 26: ...reports if the tracker keep speeding The unit is second Notes This console menu corresponds to ORION Protocol command ActSetSpeed 2 When you finish the Speed Limit Report Settings type E to return to...

Страница 27: ...ote Before connecting OBDtrac to your server A Gateway Server which runs the tcpserver exe with a public IP address must be ready The tcpserver exe is basically a TCP socket listener that builds the s...

Страница 28: ...DMMYYHHmmss A V GPS Data is Valid or Invalid A valid V invalid Longitude GPS Longitude E W E East W West Latitude GPS Latitude N S N North S South Satellite Numbers Satellite Numbers acquired The maxi...

Страница 29: ...ows the SYNC packet and GPS data on the Demo window too You can compare them to those showing on the Hyper Terminal window 5 If OBDtrac cannot connect to the Gateway Server and send GPS data please ch...

Страница 30: ...by Hyper Terminal or by GPRS 2 It takes only 3 steps to update the firmware by Hyper Terminal and the task can be done under the regular Debug Mode via RS 232 connection to PC 3 Please follow the inst...

Страница 31: ...007 ORION Technology LTD All rights reserved 31 40 Step 2 Wait until the file has been uploaded the following messages should show up to indicate the new firmware is received successfully by the track...

Страница 32: ...only 3 steps to update the firmware over the air by GPRS Please follow the instructions below to update the firmware of the tracker Step 1 Put the new firmware on a web server and come out the URL Ex...

Страница 33: ...me Note Weak GSM signal or broken image file may cause download problems We recommend you to test and verify the firmware update process before mass deployment 4 If the firmware update is successful i...

Страница 34: ...connect to Gateway Server GPS OFF GPS module OFF or Error Flash Searching GPS signal ON GPS fixed 3 Troubleshooting of the GPS tracker I The tracker is disconnected to the server and the PWR LED is O...

Страница 35: ...LED is constant OFF or flashing Cause Solution Poor GSM signal reception 1 Use the cell phone to check if the GSM signal is weak there If yes move the vehicle for better GSM reception and check again...

Страница 36: ...ply power to the tracker and check the tracker by Hyper Terminal for further information III The tracker connects to the server with invalid GPS all the time and the GPS LED is not constant ON Problem...

Страница 37: ...7 ORION Technology LTD All rights reserved 37 40 2 When the tracker is back to the office Use the AC adapter to supply power to the tracker and check the tracker by Hyper Terminal for further informat...

Страница 38: ...2007 ORION Technology LTD All rights reserved 38 40 6 OBDtrac Dongle Wiring Diagram...

Страница 39: ...separation distance of at least 20 cm must be maintained between the antenna of this device and all persons Pour se conformer aux exigences de conformit CNR 102 RF exposition une distance de s paratio...

Страница 40: ...is obligatory for products it applies to the manufacturer affixes the marking in order to be allowed to sell his product in the European market This product conforms to the essential requirements of...

Отзывы: