  The lubricator supplies and oil mist to the nailer. 

  Inspect the lubricator before operation to be sure the supply of lubricant is adequate. 

  If an inline lubricator is not used, a few drops of oil will need to be added to the nailer 

inlet before each use. 

3.    Air Hose 
      Air hose must have a minimum working pressure rating of 180 psi. 

Hose has a min. ID of 1/4"(ISO 7-1) and max. length of no more than 17'(5 meter). 
The supply hose should contain a fitting that will provide "quick disconnecting" from the 
male plug on the tool. 

Operating Pressure 

  Recommended operating pressure range is 70 to 100 psi. 

  Maximum permissible operating pressure is 120 psi. 

  Select the operating pressure within this range for the best fastener performance. The 

nail length and thickness and the hardness of the wood are factors in determining what 
the pressure should be set at. 

  Do not exceed this recommended operating pressure. 

NOTE: 

Dirt and water in the air supply are major causes of wear in the tool.

  

An air filter will help to get the best performance and minimum wear from the tool. Frequent, 
but not excessive, lubrication is required for the best performance. Oil added through the air 
line connection will lubricate the internal parts. 

 
 
 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

 

 

 

WARNING 

NEVER connect nailer to pressure which potentially exceed 
120psi. 

DO NOT USE THE WRONG FITTING ON NAILER. 

The nailer and air hose must have a hose coupler so that all 
pressure is removed from the nailer when the coupler is 
disconnected. The connector on the tool must not hold pressure 
when the air supply is disconnected. If the wrong fitting is used, 
the tool can remain charged with air after disconnecting and thus 
will be able to drive a nail even after the air line is disconnected, 
possibly causing injury.

 

 

 

DANGER 

NEVER use oxygen or other bottled gases, as an 
explosion may occur. 

Содержание CN80

Страница 1: ...y understand the instructions in this manual before operating the pneumatic power tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the Manual be kept readily available as an important reference when using this tool ...

Страница 2: ...nailers are caused by the failure to observe basic safety rules or precautions An accident can often be avoided by recognizing a potentially hazardous situation before it occurs and by observing appropriate safety procedures Basic safety precautions are outlined in the SAFETY section of this manual and in the sections which contain the operation and maintenance instructions Hazards that must be av...

Страница 3: ...fessional training or experience have sufficient expertise in the field of fastener driving tools and sufficient familiarity with relevant governmental industrial protection provisions accident prevention regulations directives and generally recognized technical regulations e g CEN and CENELEC standards to be able to assess the safe working condition of fastener driving tools g Stands for mounting...

Страница 4: ...evels which can lead to hearing damage the employer and user should ensure that any necessary hearing protection is provided and used by the operator and others in the work area 3 DO NOT USE ANY POWER SOURCE EXCEPT AN AIR COMPRESSOR The tool is designed to operate on compressed air Do not operate the tool on any other high pressure gas combustible gases e g Oxygen acetylene etc since there is the ...

Страница 5: ...Whenever the air supply is connected to the tool never touch the trigger unless you intend to drive a fastener into the work It is dangerous to walk around carrying the tool with the trigger pulled and this and similar actions should be avoided 10 NEVER POINT THE DISCHARGE OUTLET TOWARD YOURSELF AND PERSONNEL If the discharge outlet is pointed toward people serious accidents may be caused when mis...

Страница 6: ...r may result Do not interfere with the proper operation of the contact trip mechanism 18 WHEN USING THE TOOL OUTSIDE OR ELEVATED PLACE When fastening roofs or similar slanted surface start fastening at the lower part and gradually work your way up Fastening backward is dangerous as you may lose your foot place Secure the hose at a point close to the area you are going to driver fasteners Accidents...

Страница 7: ...zine capacity 225 300 nails Maximum allowable pressure 8 3 bar 120psi Recommended pressure range 5 bar to 7 bar 70psi to 100psi Fasteners Only the nail sizes shown in the table below can be driven with this nailer 15 wire welded coil nails Applications Making pallets drums and export wooden boxes Crating Making wooden fence General construction applications ...

Страница 8: ...pply compressed air to this nailer Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The female coupler will connect to the quick release that fits the tool 2 Filter Regulator Lubricator NEVER connect nailer to pressure which potentially exceeds 120psi Filter regulator lubricator units suppl...

Страница 9: ... wood are factors in determining what the pressure should be set at Do not exceed this recommended operating pressure NOTE Dirt and water in the air supply are major causes of wear in the tool An air filter will help to get the best performance and minimum wear from the tool Frequent but not excessive lubrication is required for the best performance Oil added through the air line connection will l...

Страница 10: ...ing the hands or body by mistake Nail loading 1 Disconnect the air hose 2 Press LATCH 200070 to open DOOR 210050 then open MAGAZINE COVER 420190 3 Adjust the height of NAIL SUPPORT 420210 according to nails length 4 Fix the first nail in the groove on FEED PAWL 210080 5 Close the MAGAZINE COVER 420190 close the DOOR 210050 6 Connect the air hose Test operation 1 Adjust the air pressure at 70psi 5 ...

Страница 11: ... the nailer rail with nailer lubricant Clearing a jam Remove a jammed nail in the following order 1 DISCONNECT AIR HOSE 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In case of frequent jams contact an authorized service center A qualified person should perform repair and maintenance Periodic maintenance to be performed Check that the piston bumper is operating norm...

Страница 12: ...26 410120 BUMPER B 80 110030 END CAP 27 610330 NUT M6 Nylock 81 510760 O RING 58X3 55 28 420180 GUARD COVER 82 630020 SNAP RING 52 29 320220 SAFETY 83 420190 MAGAZINE COVER 30 620100 SAFETY SPRING 84 420520 SPRING HOLDER A 31 320200 CHECK PAWL PIN 85 420210 NAIL SUPPORT PLATE 32 210050 DOOR 86 620650 MAGAZINE SPRING 33 640080 ROLL PIN 3X12 87 420230 MAGAZINE POST 34 620240 LATCH SPRING 88 630030 W...

Страница 13: ...13 TOOL SCHEMATIC CN80 ...

Страница 14: ...14 IMPORTER NOBE ApS Bjødstrupvej 10 DK 8410 Rønde Denmark Tel 45 8615 1913 E Mail info nobe dk www nobe dk www rgneurope com Industrial Coil Nailer CN80 2016 ...

Отзывы: