![ORiNG TES-3080-M12 Series Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/oring/tes-3080-m12-series/tes-3080-m12-series_user-manual_1651980081.webp)
TES-3080-M12(-BP2) User Manual
ORing Industrial Networking Corp
80
Jabber
Total frames received with a length of more than MaxSize octets
but with an invalid FCS
InMACRcvErr
Total frames received with an RxErr signal from the PHY
InFCSErr
Total frames received with a CRC error not counted in Fragments,
Jabber or RxErr.
Collisions
The number of frames for which one or more collisions occurred
when the frames were sent, including single, multiple, excessive, or
late collisions. This counter is applicable in half-duplex only.
Late
When a collision is detected by a station after it has sent the 512th
bit of its frame, it is counted as a late collision. This counter is
applicable in half-duplex only.
Port Monitoring
The switch supports several types of port monitoring including TX (egress) only, RX (ingress)
only, and both TX/RX monitoring. TX monitoring sends any data that egress out checked TX
source ports to a selected TX destination port as well. RX monitoring sends any data that
ingress in checked RX source ports out to a selected RX destination port as well as sending
the frame where it normally would have gone. Note that keep all source ports unchecked in
order to disable port monitoring.
Label
Description
Destination Port
The port will receive a copied frame from source port for monitoring
purpose.
Source Port
Check to monitor specific ports
TX
The frames transmitted by a port
RX
The frames received by a port
Apply
Click to activate the configurations.
Clear
Clears all checked boxes (disable the function)
Help
Shows help file