TES-3080-M12(-BP2) User Manual
ORing Industrial Networking Corp
12
3.2.1 Grounding
Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the ground screw on the power connector to the
grounding surface prior to connecting devices.
3.2.2 Relay Output
The device uses a M12 A-coded 5-pin female connector on the front panel for relay output.
The relay contacts will detect user-configured events and form an open circuit when an event
is triggered.
3.2.3 Power Input
The switch provides two sets of power supply on a M23 5-pin female connector to enable
power input.
Step 1
: Insert a power cable to the power connector on the device.
Step 2
: Rotate the outer ring of the cable connector until a snug
fit is achieved
. Make sure
the connection is tight.
3.3 Cables
3.3.1 Ethernet Connection
The series provide Ethernet ports in M12 connectors. According to the link type, the switch
uses CAT 3, 4, 5,5e UTP cables to connect to any other network devices (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications