![ORiNG TES-3080-M12 Series Скачать руководство пользователя страница 111](http://html1.mh-extra.com/html/oring/tes-3080-m12-series/tes-3080-m12-series_user-manual_1651980111.webp)
TES-3080-M12(-BP2) User Manual
ORing Industrial Networking Corp
110
10/100Base-T(X) M12 Port
Indicator
Green for port Link/Act: On for link-up, Off for link-down, Blinking for Act.
Amber for Duplex/Collision: On for Full-Duplex, Off for Half-Duplex, Blinking for Half-Duplex and collision
occurs
Fault Contact
Relay
Relay output to carry capacity of 3A at 24VDC on M12 connector (5-pin A-coding, female connector)
Reset Function
Reset Button
< 5 sec: System reboot, > 5 sec: Factory default
Power
Input Power
Dual 12-48VDC on 5-pin M23 female connector
*NOTICE: For EN50155 applications, it supports 24VDC power input only.
Power Consumption (Typ.)
5 Watts
Total PoE Output Power
95 Watts
Overload Current Protection
Present
Reverse Polarity Protection
Present
Physical Characteristic
Enclosure
IP-30
Dimension (W x D x H)
125 (W) x 65 (D) x 196 (H) mm
4.92 (W) x 2.56 (D) x 7.72 (H) inch
Weight (g)
894 g
Environmental
Storage Temperature
-40 to 85
o
C (-40 to 185
o
F)
Operating Temperature
-40 to 75
o
C (-40 to 167
o
F)
Operating Humidity
5% to 95% non-condensing
Regulatory Approvals
EMC
CE EMC (EN 55024, EN 55022), FCC Part 15 B, EN 50155(EN 50121-1, EN 50121-3-2)
EMI
EN 55022, CISPR32, EN 61000-3-2, EN 61000-3-3, FCC Part 15 B class A
EMS
EN 55024 (IEC/EN 61000-4-2 (ESD), IEC/EN 61000-4-3 (RS), IEC/EN 61000-4-4 (EFT), IEC/EN 61000-4-5
(Surge), IEC/EN 61000-4-6 (CS), IEC/EN 61000-4-8(PFMF), IEC/EN 61000-4-11 (DIP))
Shock
IEC60068-2-27
Free Fall
IEC60068-2-31
Vibration
IEC60068-2-6
Safety
EN 60950-1
Other
EN 50155 (IEC 61373)
MTBF
772743.7657 hrs.
815272.4837 hrs.
Warranty
5 years