background image

 

IES-3162GC 

User’s  Manual 

 

ORing Industrial Networking Corp 

69 

The following table describes the labels in this screen. 

Label 

Description 

System Event

 

System Cold Start

 

Alert when system restart 

Power Status 

Alert when a power up or down 

SNMP Authentication 

Failure 

Alert when SNMP authentication failure. 

O-Ring Topology 

Change 

Alert when O-Ring topology changes.     

Port Event 

SYSLOG / SMTP 

event 

 

Disable

   

 

Link Up

   

 

Link Down

   

 

Link Up & Link Down

   

Apply 

Click “

Apply

” to activate the configurations. 

Help 

Show help file. 

 

 

5.1.14  Monitor and Diag 

5.1.14.1  MAC Address Table 

Refer to IEEE 802.1 D Sections 7.9.    The MAC Address Table, that is Filtering Database, 

supports queries by the Forwarding Process, as to whether a frame received by a given port 

with a given destination MAC address is to be forwarded through a given potential 

transmission port. 

Содержание IES-3162GC Series

Страница 1: ...oad Xindian District New Taipei City 231 Taiwan Tel 886 2 2218 1066 Fax 886 2 2218 1014 Website www oring networking com E mail support oring networking com Manufacturer s Documents Title Drawing No Rev Level Date IES 3162GC user manual IES 3162GC user s manual V1 4 2015 08 14 IES A3162GC user manual IES A3162GC user s manual V1 4 2015 08 14 ...

Страница 2: ...Mounting Installation 7 2 2 1 Mount IES 3162GC on the wall 7 Hardware Overview 9 3 1 Front Panel 9 3 2 Front Panel LEDs 11 3 3 Top view Panel 12 3 4 Rear Panel 12 Cables 13 4 1 Ethernet Cables 13 4 1 1 10 100 100BASE TX 10BASE T Pin Assignments 13 4 2 SFP 14 4 3 Console Cable 15 WEB Management 16 5 1 Configuration by Web Browser 16 5 1 1 About Web based Management 16 5 1 2 System Information 18 5 ...

Страница 3: ...Status 30 5 1 6 3 Port Alias 30 5 1 6 4 Rate Limit 31 5 1 6 5 Port Trunk 32 5 1 7 Redundancy 34 5 1 7 1 O Ring 34 5 1 7 2 Open Ring 35 5 1 7 3 O RSTP 37 5 1 7 4 RSTP 38 5 1 7 5 MSTP 41 5 1 8 VLAN 45 5 1 8 1 VLAN Setting 45 5 1 8 2 VLAN Setting Port Based 47 5 1 9 SNMP 49 5 1 9 1 SNMP Agent Setting 49 5 1 9 2 SNMP Trap Setting 50 5 1 10 Traffic Prioritization 51 5 1 11 Multicast 56 5 1 11 1 IGMP Sn...

Страница 4: ...Commands Set 82 6 3 Commands Set List Port Commands Set 84 6 4 Commands Set List Trunk command set 87 6 5 Commands Set List VLAN command set 88 6 6 Commands Set List Spanning Tree command set 89 6 7 Commands Set List QoS command set 91 6 8 Commands Set List IGMP command set 92 6 9 Commands Set List MAC Filter Table command set 93 6 10 Commands Set List SNMP command set 93 6 11 Commands Set List Po...

Страница 5: ...nd monitor switches status 1 2 Software Features World s fastest Redundant Ethernet Ring O Ring Recovery time 10ms over 250 units connection Supports Ring Coupling Dual Homing over O Ring and standard STP RSTP Supports SNMPv1 v2c v3 RMON Port base 802 1Q VLAN Network Management Event notification by Email SNMP trap and Relay Output Web based Telnet Console CLI configuration Enable disable ports MA...

Страница 6: ... Wide Operating Temperature 40 to 60oC Storage Temperature 40 to 85oC Operating Humidity 5 to 95 non condensing Casing IP 30 10 100 1000Base T X Gigabit Ethernet port combo port 10 100Base T X Ethernet port 100 1000Base X on SFP port combo port Console Port Dimensions W x D x H 96 4 mm W x 108 5 mm D x 154 mm H ...

Страница 7: ...witch has a DIN Rail kit on rear panel The DIN Rail kit helps switch to fix on the DIN Rail It is easy to install the switch on the DIN Rail 2 1 1 Mount IES 3162GC on DIN Rail Step 1 Slant the switch and mount the metal spring to DIN Rail Step 2 Push the switch toward the DIN Rail until you heard a click sound Metal Spring ...

Страница 8: ...on method for users to fix the switch A wall mount panel can be found in the package The following steps show how to mount the switch on the wall 2 2 1 Mount IES 3162GC on the wall Step 1 Remove DIN Rail kit Step 2 Use 6 screws that can be found in the package to combine the wall mount panel Just like the picture shows below ...

Страница 9: ...l ORing Industrial Networking Corp 8 The screws specification shows in the following two pictures In order to prevent switch from any damage the screws should not larger than the size that used in IES 3162GC switch Pozidrive ...

Страница 10: ... 8 10 100Base T X RJ 45 fast Ethernet ports support auto negotiation Default Setting Speed auto Duplex auto Flow control disable Gigabit RJ 45 port 2 10 100 1000Base TX Giga ports combo Fiber port 2 100 1000Base X on SFP port combo Console Use RS 232 to RJ 45 connecter to manage switch Reset Push reset button 2 to 3 seconds to reset the switch Push reset button 5 seconds to reset the switch into F...

Страница 11: ...the switch is the ring master of Ring 5 LED for Ring When the led light on it means the Ring is activated 6 LED for Fault When the light on it means Power failure or Port down fail 7 Console port RJ 45 8 Reset button Push the button 3 seconds for reset 5 seconds for factory default 9 1000Base X COMBO SFP Port Link Act LED 10 1000Base T gigabits Ethernet port COMBO 1000Base X Fiber port on SFP 11 1...

Страница 12: ...blinking Ring has only One link lack of one link to build the ring Fast blinking Ring work normally Fault Amber On Fault relay Power failure or Port down fail 10 100Base T X Fast Ethernet ports LNK ACT Green On Port link up Blinking Data transmitted Full Duplex Amber On Port works under full duplex Gigabit Ethernet ports LNK ACT Green On Port link up Blinking Data transmitted Indicator Amber On Po...

Страница 13: ...erminal block includes PWR1 PWR2 48V DC Suitable for 12 28 AWG 3 3mm2 0 08mm2 wire size torque value 4 5 lb in 0 508 N m 2 Ground wire The minimum cross sectional area of Earthing conductor shall equal to input wiring cable 3 4 Rear Panel The components in the rare of IES 3162GC are shown as below 1 Screw holes for wall mount kit 2 DIN Rail kit ...

Страница 14: ...ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 1000BASE TX Cat 5 Cat 5e 100 ohm UTP UTP 100 m 328ft RJ 45 4 1 1 10 100 100BASE TX 10BASE T Pin Assignments With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 are used for receiving data 1000 Base T RJ 45 Pin Assignments Pin Number Assignment 1 BI_DA 2 BI_DA 3 BI_DB 4 BI_DC 5 BI_DC 6 BI_DB 7 BI_DD...

Страница 15: ...ceive TD transmit 7 Not used Not used 8 Not used Not used 1000 Base T MDI MDI X pins assignment Pin Number MDI port MDI X port 1 BI_DA BI_DB 2 BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC Note and signs represent the polarity of the wires that make up each wire pair 4 2 SFP The IES 3162GC has fiber optical ports with SFP connectors The fiber optic...

Страница 16: ... Laser Class 1 Switch A Switch B 4 3 Console Cable IES 3162GC switch can be management by console port The DB 9 to RJ 45 cable can be found in the package You can connect them to PC via a RS 232 cable with DB 9 female connector and the other end RJ 45 connector connects to console port of switch PC pin out male assignment RS 232 with DB9 female connector DB9 to RJ 45 Pin 2 RD Pin 2 TD Pin 2 Pin 3 ...

Страница 17: ... Management function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing screen Note By default IE5 0 or later version does not allow Java Applets to open sockets You need to explicitly modify the browser setting in order to enable Java Applets to use network ports Preparing for Web...

Страница 18: ...rking Corp 17 3 The login screen appears 4 Key in the username and password The default username and password is admin 5 Click Enter or OK button then the main interface of the Web based management appears Login screen Main Interface Main interface ...

Страница 19: ... Information The system information will display the configuration of Basic Setting Switch Setting page Enable Location Alert When click PWR1 PWR2 and PWR3 LEDs of the switch will start to flash together and click the LEDs will stop flashing 5 1 3 Front Panel Show the panel of IES 3162GC Click Close to close panel on web ...

Страница 20: ... length is 64 bytes System Description Display the description of switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization System OID Display the switch s OID information Firmware Version Display the switch s firmware version Kernel Version Display the kernel software version MAC Address Display the un...

Страница 21: ...llowing table describes the labels in this screen Label Description User name Key in the new username The default is admin New Password Key in the new password The default is admin Confirm password Re type the new password Apply Click Apply to activate the configurations 5 1 4 3 IP Setting You can configure the IP Settings and DHCP client function through IP configuration IP Configuration interfac...

Страница 22: ...e DHCP server IP Address Assign the IP address that the network is using If DHCP client function is enabling you do not need to assign the IP address The network DHCP server will assign the IP address for the switch and it will be display in this column The default IP is 192 168 10 1 Subnet Mask Assign the subnet mask of the IP address If DHCP client function is enabling you do not need to assign ...

Страница 23: ... switch location time zone The following table lists the different location time zone for your reference Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11 am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylight 4 hours 8 am EST Eastern Standard CDT Central Daylight 5 hours 7 am CST Central Standard MDT Mountain...

Страница 24: ... USSR Zone 4 5 hours 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CCT China Coast USSR Zone 7 8 hours 8 pm JST Japan Standard USSR Zone 8 9 hours 9 pm EAST East Australian Standard GST Guam Standard USSR Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight Label Description SNTP Sever IP Address Set the SNTP ...

Страница 25: ...figuration interface The following table describes the labels in this screen Label Description LLDP Protocol Enable or Disable LLDP function LLDP Interval The interval of resend LLDP by default at 30 seconds Apply Click Apply to activate the configurations Help Show help file 5 1 4 6 Auto Provision Auto Provision allows you to update the switch firmware automatically You can put firmware or config...

Страница 26: ...rver in this page Backup Restore interface The following table describes the labels in this screen Label Description TFTP Server IP Address Fill in the TFTP server IP Restore File Name Fill the file name Restore Click restore to restore the configurations Restore File Name Fill the file name Restore Click restore to restore the configurations Backup Click backup to backup the configurations ...

Страница 27: ...of switch Before updating make sure you have your TFTP server ready and the firmware image is on the TFTP server Update Firmware interface 5 1 5 DHCP Server 5 1 5 1 DHCP Server Setting The system provides with DHCP server function Enable the DHCP server function the switch system will be a DHCP server DHCP Server Configuration interface ...

Страница 28: ... 168 1 200 192 168 1 200 will be the End IP address Subnet Mask The dynamic IP assign range subnet mask Gateway The gateway in your network DNS Domain Name Server IP Address in your network Lease Time Hour It is the period that system will reset the assigned dynamic IP to ensure the IP address is in used Apply Click Apply to activate the configurations 5 1 5 2 DHCP Server Client List When the DHCP...

Страница 29: ...IES 3162GC User s Manual ORing Industrial Networking Corp 28 DHCP Server Port and IP Binding interface ...

Страница 30: ...ble describes the labels in this screen Label Description Port NO Port number for setting Speed Duplex You can set Auto negotiation 100 full 100 half 10 full or 10 half Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred Security Support port security function When enable the function the port will STOP learning MAC address dynamically Apply Click Apply...

Страница 31: ...l Networking Corp 30 5 1 6 2 Port Status The following information provides the current port status information Port Status interface 5 1 6 3 Port Alias The user can define the name of every Port Can let user convenient management every Port ...

Страница 32: ...or Egress to limit traffic received or transmitted bandwidth Rate Limit interface The following table describes the labels in this screen Label Description Ingress Limit Frame Type You can set all Broadcast only Broadcast Multicast or Broadcast Multicast Flooded Unicast mode Ingress The switch port received traffic Egress The switch port transmitted traffic Apply Click Apply to activate the config...

Страница 33: ... 802 3ad LACP to combine several physical links with a logical link to increase the bandwidth Port Trunk Setting interface The following table describes the labels in this screen Label Description Group ID Select port to join a trunk group Type Support static trunk and 802 3ad LACP Apply Click Apply to activate the configurations ...

Страница 34: ...IES 3162GC User s Manual ORing Industrial Networking Corp 33 Port Trunk Status You can check the configuration of port trunk Port Trunk Status interface ...

Страница 35: ... Ring Master There should be one and only one Ring Master in a ring However if there are two or more switches which set Ring Master to enable the switch with the lowest MAC address will be the actual Ring Master and others will be Backup Masters 1st Ring Port The primary port when this switch is configured in O Ring 2nd Ring Port The backup port when this switch is configured in O Ring Coupling Ri...

Страница 36: ...inks i e backbone Switch The two links act as active backup mode and connect each Ring to the normal switches in RSTP mode Apply Click Apply to activate the configurations Note It is not recommended to set one switch as a Ring Master and a Coupling Ring at the same time due to heavy load of system 5 1 7 2 Open Ring Open Ring technology can be applied for other vendor s proprietary ring Thus you ca...

Страница 37: ...ble Enabling the Open Ring function Vender Choosing the venders that you want to join to their ring 1st Ring Port Choosing the port which connect to the ring 2nd Ring Port Choosing the port which connect to the ring The application of Open Ring is shown as below Open Ring connection ...

Страница 38: ... RSTP is proprietary redundant ring technology invented by ORing Different from standard STP RSTP the recovery time of O RSTP is less than 10mS and support more nodes of connection in a ring topology O RSTP interface The application of O RSTP is shown as below O RSTP connection ...

Страница 39: ...e Spanning Tree Protocol STP It provides faster convergence of spanning tree after a topology change The system also supports STP and the system will detect the connected device that is running STP or RSTP protocol automatically RSTP setting You can enable disable RSTP function and set parameters for each port RSTP Setting interface ...

Страница 40: ...ning state to forwarding state Enter a value between 4 through 30 Path Cost 1 200000000 The cost of the path to the other bridge from this transmitting bridge at the specified port Enter a number 1 through 200000000 Priority 0 240 Decide which port should be blocked by setting the priority in LAN Enter a number 0 through 240 The value of priority must be the multiple of 16 Admin P2P Some of the ra...

Страница 41: ...ck Apply to activate the configurations NOTE Follow the rule to configure the MAX Age Hello Time and Forward Delay Time 2 x Forward Delay Time value 1 Max Age value 2 x Hello Time value 1 RSTP Information Show RSTP algorithm result at this table RSTP Information interface ...

Страница 42: ...g table describes the labels in this screen Label Description MSTP Enable You must enable or disable MSTP function before configuring the related parameters Force Version The Force Version parameter can be used to force a VLAN Bridge that supports RSTP to operate in an STP compatible manner Configuration Name The same MST Region must have the same MST configuration name Revision Level 0 65535 The ...

Страница 43: ...switch sends out the BPDU packet to check RSTP current status Enter a value between 1 through 10 2 x Forward Delay Time value 1 Max Age value 2 x Hello Time value 1 Forwarding Delay Time 4 30 The number of seconds a port waits before changing from its Rapid Spanning Tree Protocol learning and listening states to the forwarding state Enter a value between 4 through 30 Max Hops 1 40 This parameter i...

Страница 44: ...Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means ...

Страница 45: ...tocol standard rule Apply Click Apply to activate the configurations MSTP Instance Port interface Label Description Instance Set the instance s information except CIST Port Selecting the port that you want to configure Priority 0 240 Decide which port should be blocked by priority in LAN Enter a number 0 through 240 The value of priority must be the multiple of 16 Path Cost 1 200000000 The cost of...

Страница 46: ...AN Setting Tagged based VLAN is an IEEE 802 1Q specification standard and t is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag contains a VLAN Identifier VID that indicates the VLAN numbers You can create Tag based VLAN and enable or disable GVRP protocol There are 256 VLAN groups available Enable...

Страница 47: ...here are 3 types of link type Access Link single switch only allows you to group ports by setting the same VID Trunk Link extended application of Access Link allows you to group ports by setting the same VID with 2 or more switches Hybrid Link Both Access Link and Trunk Link are available Hybrid QinQ Link enable QinQ mode allow you to insert one more VLAN tag in a original VLAN frame Untagged VID ...

Страница 48: ...te all unselected ports are treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored VLAN Configuration Port Base interface 1 The following table describes the labels in this screen Label Description Add Click add to enter VLAN add interface Edit Edit exist VLAN Delete Delete exist VLAN Help Show help file ...

Страница 49: ... Base interface 2 The following table describes the labels in this screen Label Description Group Name VLAN name VLAN ID Specify the VLAN ID Add Select port to join the VLAN group Remove Remove port of the VLAN group Apply Click Apply to activate the configurations Help Show help file ...

Страница 50: ...nd plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 1 9 1 SNMP Agent Setting You can set SNMP agent related information by Agent Setting Function SNMP Agent Setting interface The following table describes the labels in this screen Label Description SNMP agent Version Three SNMP versions are supported ...

Страница 51: ...ere are maximum 8 sets of SNMPv3 User and maximum 16 characters in username and password When SNMP V3 agent is selected you can 1 Input SNMPv3 username only 2 Input SNMPv3 username and Auth Password 3 Input SNMPv3 username Auth Password and Privacy Password which can be different with Auth Password To remove a current user profile 1 Input SNMPv3 user name you want to remove 2 Click Remove button C...

Страница 52: ... for authentication Trap Version Trap Version supports V1 and V2c Add Add trap server profile Remove Remove trap server profile Help Show help file 5 1 10 Traffic Prioritization Traffic Prioritization includes 3 modes port base 802 1p COS and TOS DSCP By traffic prioritization function you can classify the traffic into four classes for differential network application IES 3162GC support 4 priority...

Страница 53: ...t the output priority is determined by COS and TOS but TOS first QoS policy Using the 8 4 2 1 weight fair queue scheme the output queues will follow 8 4 2 1 ratio to transmit packets from the highest to lowest queue For example 8 high queue packets 4 middle queue packets 2 low queue packets and the one lowest queue packets are transmitted in one turn Use the strict priority scheme always the packe...

Страница 54: ...working Corp 53 Port based Priority interface Label Description Port base Priority Assign Port with a priority queue 4 priority queues can be assigned High Middle Low and Lowest Help Show help file Apply Click Apply to activate the configurations ...

Страница 55: ...IES 3162GC User s Manual ORing Industrial Networking Corp 54 COS 802 1p interface ...

Страница 56: ...ag a default priority value is considered and determined by ingress port Help Show help file Apply Click Apply to activate the configurations TOS DSCP interface Label Description TOS DSCP TOS Type of Service is a field in IP header of a packet This TOS field is also used by Differentiated Services and is called the Differentiated Services Code Point DSCP The output priority of a packet can be dete...

Страница 57: ...multicast traffic so that it travels only to those end destinations that require that traffic and reduces the amount of traffic on the Ethernet LAN IGMP Snooping interface The following table describes the labels in this screen Label Description IGMP Snooping Enable Disable IGMP snooping IGMP Query Mode Switch will be IGMP querier or not There should exist one and the only one IGMP querier in an I...

Страница 58: ...1 11 3 Multicast Filter Multicast filtering is the system by which end stations only receive multicast traffic if they register to join specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to registered end stations ...

Страница 59: ...n the range of 224 0 0 0 239 255 255 255 Member Ports Tick the check box beside the port number to include them as the member ports in the specific multicast group IP address Add Show current IP multicast list Delete Delete an entry from table Help Show help file 5 1 12 Security Five useful functions can enhance security of switch IP Security Port Security MAC Blacklist and MAC address Aging and 8...

Страница 60: ...ific IP addresses Only these secure IP addresses can manage this switch remotely IP Security interface The following table describes the labels in this screen Label Description IP security MODE Enable Disable the IP security function Enable WEB Management Mark the blank to enable WEB Management Enable Telnet Management Mark the blank to enable Telnet Management Enable SNMP Management Mark the blan...

Страница 61: ...e forwarded otherwise will be discarded Port Security interface The following table describes the labels in this screen Label Description MAC Address Input MAC Address to a specific port Port NO Select port of switch Add Add an entry of MAC and port information Delete Delete the entry Help Show help file 5 1 12 3 MAC Blacklist MAC Blacklist can eliminate the traffic forwarding to specific MAC addr...

Страница 62: ...to MAC Blacklist Port NO Select port of switch Add Add an entry to Blacklist table Delete Delete the entry Help Show help file 5 1 12 4 802 1x 802 1x Radius Server 802 1x makes the use of the physical access characteristics of IEEE802 LAN infrastructures in order to provide a authenticated and authorized devices attached to a LAN port Please refer to IEEE 802 1X Port Based Network Access Control ...

Страница 63: ...n server to authenticate Account port Set the UDP destination port for accounting requests to the specified Radius Server Shared Key A key shared between this switch and authentication server NAS Identifier A string used to identify this switch Advanced Setting Quiet Period Set the time interval between authentication failure and the start of a new authentication attempt Tx Period Set the time tha...

Страница 64: ...aits for a Radius server response to an authentication request Max Requests Set the maximum number of times to retry sending packets to the supplicant Re Auth Period Set the period of time after which clients connected must be re authenticated Apply Click Apply to activate the configurations Help Show help file 802 1x Port Authorized Mode Set the 802 1x authorized mode of each port 802 1x Port Aut...

Страница 65: ...tication Disable this port will not participate in 802 1x Apply Click Apply to activate the configurations Help Show help file 802 1x Port Authorized State Show 802 1x port authorized state 802 1x Port Authorize State interface 5 1 13 Warning Warning function is very important for managing switch You can manage switch by SYSLOG E MAIL and Fault Relay It helps you to monitor the switch status on re...

Страница 66: ...bel Description Power Failure Mark the blank of PWR 1 or PWR 2 to monitor Port Link Down Broken Mark the blank of port 1 to port 8 to monitor Apply Click Apply to activate the configurations Help Show help file 5 1 13 2 System Alarm System alarm support two warning mode 1 SYSLOG 2 E MAIL You can monitor switch through selected system events System Warning SYSLOG Setting The SYSLOG is a protocol to...

Страница 67: ... to local system Server Only log to a remote SYSLOG server Both log to both of local and remote server SYSLOG Server IP Address The remote SYSLOG Server IP address Apply Click Apply to activate the configurations Help Show help file System Warning SMTP Setting The SMTP is Short for Simple Mail Transfer Protocol It is a protocol for e mail transmission across the Internet Please refer to RFC 821 Si...

Страница 68: ...ission system warning events by e mail Sender E mail Address The SMTP server IP address Mail Subject The Subject of the mail Authentication Username the authentication username Password the authentication password Confirm Password re enter password Recipient E mail Address The recipient s E mail address It supports 6 recipients for a mail Apply Click Apply to activate the configurations Help Show ...

Страница 69: ...ection SYSLOG and SMTP are the two warning methods that supported by the system Check the corresponding box to enable system event warning method you wish to choose Please note that the checkbox can not be checked when SYSLOG or SMTP is disabled System Warning Event Selection interface ...

Страница 70: ...ology Change Alert when O Ring topology changes Port Event SYSLOG SMTP event Disable Link Up Link Down Link Up Link Down Apply Click Apply to activate the configurations Help Show help file 5 1 14 Monitor and Diag 5 1 14 1 MAC Address Table Refer to IEEE 802 1 D Sections 7 9 The MAC Address Table that is Filtering Database supports queries by the Forwarding Process as to whether a frame received b...

Страница 71: ... Port NO Show all MAC addresses mapping to a selected port in table Clear MAC Table Clear all MAC addresses in table Help Show help file 5 1 14 2 MAC Address Aging You can set MAC Address aging timer as time expired the unused MAC will be cleared from MAC table IES 3162GC also support Auto Flush MAC Address Table When ports Link Down MAC Address Aging interface ...

Страница 72: ...ng is 300 seconds Auto Flush MAC Address Table When ports Link Down Enable this function Apply Click Apply to activate the configurations Help Show help file 5 1 14 3 Port Statistics Port statistics show several statistics counters for all ports Port Statistics interface The following table describes the labels in this screen Label Description Type Show port speed and media type Link Show port lin...

Страница 73: ...sion The number of times a collision detected by this port Clear Clear all counters Help Show help file 5 1 14 4 Port Monitoring Port monitoring function supports TX egress only RX ingress only and both TX RX monitoring TX monitoring sends any data that egress out checked TX source ports to a selected TX destination port as well RX monitoring sends any data that ingress in checked RX source ports ...

Страница 74: ...stination Port The port will receive a copied frame from source port for monitoring purpose Source Port The port will be monitored Mark the blank of TX or RX to be monitored TX The frames come into switch port RX The frames receive by switch port Apply Click Apply to activate the configurations Clear Clear all marked blank disable the function Help Show help file ...

Страница 75: ...gs will be shown in this table System event log interface The following table describes the labels in this screen Label Description Page Select LOG page Reload To get the newest event logs and refresh this page Clear Clear log Help Show help file 5 1 14 6 Ping Ping function allows the switch to send ICMP packets to detect the remote notes ...

Страница 76: ...ress Enter the IP address that you want to detect Active Click Active to send ICMP packets 5 1 15 Save Configuration If any configuration changed Save Configuration should be clicked to save current configuration data to the permanent flash memory Otherwise the current configuration will be lost when power off or system reset System Configuration interface ...

Страница 77: ...nfigurations Help Show help file 5 1 16 Factory Default Factory Default interface Reset switch to default configuration Click Reset to reset all configurations to the default value You can select Keep current IP address setting and Keep current username password to keep current IP and username and password 5 1 17 System Reboot System Reboot interface ...

Страница 78: ...sole or telnet to management switch by CLI CLI Management by RS 232 Serial Console 9600 8 none 1 none Before Configuring by RS 232 serial console use an RJ45 to DB9 F cable to connect the Switches RS 232 Console port to your PC s COM port Follow the steps below to access the console via RS 232 serial cable Step 1 From the Windows desktop click on Start Programs Accessories Communications Hyper Ter...

Страница 79: ...IES 3162GC User s Manual ORing Industrial Networking Corp 78 Step 2 Input a name for new connection Step 3 Select to use COM port number ...

Страница 80: ...port properties setting 9600 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 The Console login screen will appear Use the keyboard to enter the Username and Password The same with the password for Web Browser then press Enter ...

Страница 81: ...sk 255 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of the switch from the Windows Run command or from the MS DOS prompt as below Step 2 The Login screen will appear Use the keyboard to enter the Username and Password The same with the password for Web Browser and then press Enter ...

Страница 82: ...play advance function status save configures Global configuration Enter the configure command while in privileged EXEC mode switch co nfig To exit to privileged EXEC mode enter exit or end Use this mode to configure parameters that apply to your Switch as a whole VLAN database Enter the vlan database command while in privileged EXEC mode switch vla n To exit to user EXEC mode enter exit Use this m...

Страница 83: ...ch write memory system name System Name G Configure system name switch config system name xxx system location System Location G Set switch system location string switch config system location xxx system description System Description G Set switch system description string switch config system description xxx system contact System Contact G Set switch system contact window string switch config syst...

Страница 84: ... G Configure high IP address for IP pool switch config dhcpserver highip 192 168 1 50 dhcpserver subnetmask Subnet mask G Configure subnet mask for DHCP clients switch config dhcpserver subnetmask 255 255 255 0 dhcpserver gateway Gateway G Configure gateway for DHCP clients switch config dhcpserver gateway 192 168 1 254 dhcpserver dnsip DNS IP G Configure DNS IP for DHCP clients switch config dhcp...

Страница 85: ...ble IP security function switch config no security no security http G Disable IP security of HTTP server switch config no security http no security telnet G Disable IP security of telnet server switch config no security telnet 6 3 Commands Set List Port Commands Set IES 3162GC Commands Level Description Example interface fastEthernet Portid G Choose the port for modification switch config interfac...

Страница 86: ...ess limit frame type to accept all frame switch config interface fastEthernet 2 switch config if bandwidth type all bandwidth type broadcast multicast floo ded unicast I Set interface ingress limit frame type to accept broadcast multicast and flooded unicast frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast multicast flooded unicast bandwidth type broadcast mul...

Страница 87: ...bandwidth state Enable Disable I Use the state interface configuration command to specify the state mode of operation for Ethernet ports Use the disable form of this command to disable the port switch config interface fastEthernet 2 switch config if state Disable show interface configuration I show interface configuration status switch config interface fastEthernet 2 switch config if show interfac...

Страница 88: ...t list lacp workp Workport G Assign a trunk group with LACP active GroupID 1to3 Port list Member port list This parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports switch config aggregator group 1 1 4 lacp workp 2 or switch config aggregator group 2 1 ...

Страница 89: ...21q port PortNumber access link untag UntaggedVID V Assign a access link for VLAN by port if the port belong to a trunk group this command can t be applied switch vlan vlan 802 1q port 3 access link untag 33 vlan 8021q port PortNumber trunk link tag TaggedVID List V Assign a trunk link for VLAN by port if the port belong to a trunk group this command can t be applied switch vlan vlan 8021q port 3 ...

Страница 90: ...witch vlan vlan 8021q aggreator 3 hybrid link untag 5 tag 6 8 show vlan VID or show vlan V Show VLAN information switch vlan show vlan 23 6 6 Commands Set List Spanning Tree command set IES 3162GC Commands Level Description Example spanning tree enable G Enable spanning tree switch config spanning tree enable spanning tree priority 0to61440 G Configure spanning tree priority parameter switch confi...

Страница 91: ... tree forward time seconds G Use the spanning tree forward time global configuration command to set the forwarding time for the specified spanning tree instances The forwarding time determines how long each of the listening and learning states last before the port begins forwarding switch config spanning tree forward time 20 stp path cost 1to200000000 I Use the spanning tree cost interface configu...

Страница 92: ...this interface switch config interface fastEthernet 2 switch config if stp admin p2p Auto stp admin edge True False I Admin Edge of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin edge True stp admin non stp True False I Admin NonSTP of STP priority on this interface switch config interface fastEthernet 2 switch config if stp admin non stp False Sho...

Страница 93: ...qos priority tos 3 high show qos P Display the information of QoS configuration switch show qos no qos G Disable QoS function switch config no qos 6 8 Commands Set List IGMP command set IES 3162GC Commands Level Description Example igmp enable G Enable IGMP snooping function switch config igmp enable Igmp query auto G Set IGMP query to auto mode switch config Igmp query auto Igmp query force G Set...

Страница 94: ...static show mac address table filter P Show filter MAC address table switch show mac address table filter no mac address table static hwaddr MAC I Remove an entry of MAC address table of interface static switch config interface fastEthernet 2 switch config if no mac address table static hwaddr 000012345678 no mac address table filter hwaddr MAC G Remove an entry of MAC address table filter switch ...

Страница 95: ...p snmpv3 user test01 password AuthPW PrivPW show snmp P Show SNMP configuration switch show snmp show snmp server P Show specified trap server information switch show snmp server no snmp community strings Community G Remove the specified community switch config no snmp community strings public no snmp snmpv3 user User Name password Authentication Password Privacy Password G Remove specified user o...

Страница 96: ...thernet 2 switch config if no monitor 6 12 Commands Set List 802 1x command set IES 3162GC Commands Level Description Example 8021x enable G Use the 802 1x global configuration command to enable 802 1x protocols switch config 8021x enable 8021x system radiousip IP address G Use the 802 1x system radious IP global configuration command to change the radious server IP switch config 8021x system radi...

Страница 97: ...y the quiet period value of the switch switch config 8021x misc quietperiod 10 8021x misc txperiod sec G Use the 802 1x misc TX period global configuration command to set the TX period switch config 8021x misc txperiod 5 8021x misc supportimeout sec G Use the 802 1x misc supp timeout global configuration command to set the supplicant timeout switch config 8021x misc supportimeout 20 8021x misc ser...

Страница 98: ...switch config if 8021x portstate accept show 8021x E Display a summary of the 802 1x properties and also the port sates switch show 8021x no 8021x G Disable 802 1x function switch config no 8021x 6 13 Commands Set List TFTP command set IES 3162GC Commands Level Description Defaults Example backup flash backup_cfg G Save configuration to TFTP and need to specify the IP of TFTP server and the file n...

Страница 99: ...ow systemlog P Show system log client server information switch show systemlog no systemlog G Disable systemlog functon switch config no systemlog smtp enable G Enable SMTP function switch config smtp enable smtp serverip IP address G Configure SMTP server IP switch config smtp serverip 192 168 1 5 smtp authentication G Enable SMTP authentication switch config smtp authentication smtp account acco...

Страница 100: ...nk Down Bot h I Set port event for SMTP switch config interface fastethernet 3 switch config if event smtp both show event P Show event selection switch show event no event device cold start G Disable cold start event type switch config no event device cold start no event authentication failure G Disable Authentication failure event typ switch config no event authentication failure no event O Ring...

Страница 101: ...t yyyymmdd hh mm switch config sntp daylight period 20060101 01 01 20060202 01 01 sntp daylight offset Minute G Set offset of daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight offset 3 sntp ip IP G Set SNTP server IP if SNTP function is inactive this command can t be applied switch config sntp ip 192 169 1 1 sntp timezone Timezone G Set tim...

Страница 102: ...ingport 1st Ring Port 2nd Ring Port G Configure 1st 2nd Ring Port switch config ring ringport 7 8 Ring couplingport Coupling Port G Configure Coupling Port switch config ring couplingport 1 Ring controlport Control Port G Configure Control Port switch config ring controlport 2 Ring homingport Dual Homing Port G Configure Dual Homing Port switch config ring homingport 3 show Ring P Show the informa...

Страница 103: ... 802 1ad VLAN QinQ 802 1AB LLDP 802 1s MSTP MAC addresses 8192 Priority Queues 4 Flow Control IEEE 802 3x Flow Control and Back pressure Processing Store and Forward Interface RJ45 Ports 10 100Base T X Auto MDI MDI X Giga SFP Ports 1000 Base SFP 1000 Base T X combo LED Indicators Per Unit Power x 3 Green RJ45 Ports Per Port Link Activity Green Blinking Green Full duplex Amber Giga SFP Ports Per Po...

Страница 104: ...ed in an enclosure only accessible with the use of a tool suitable for the environment This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only WARNING _ EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous WARNING _ EXPLOSION HAZARD Substitution of any components may impair suitabilit...