Operating Temperature
-40 to 60
o
C
Storage Temperature
-40 to 85
o
C
Operating Humidity
5% to 95%, non-condensing
Mechanical
Dimensions(W x D x H)
96.4(W)x108.5(D)x154(H) mm (3.8 x 4.27 x 6.06 inch)
Casing
IP-30 protection
Regulatory Approvals
Regulatory Approvals
FCC Part 15, CISPER (EN55022) class A
EMS
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4
(EFT), EN61000-4-5 (Surge), EN61000-4-6
(CS),EN61000-4-8,EN61000-4-11
Shock
IEC 60068-2-27
Free Fall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Warranty
5 years
ATEX License Number: DEMKO 16 ATEX 1566X
ATEX information
Explosive Environment Standard: EN60079-0:2012+A11:2013; EN60079-15:2010
Warning:
- These devices are open-type devices that are to be installed in an enclosure only accessible with the
use of a tool, suitable for the environment.
- This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous
locations only.
- WARNING _ EXPLOSION HAZARD - Do not disconnect equipment unless power has been removed
or the area is known to be non-hazardous.
- WARNING _ EXPLOSION HAZARD - Substitution of any components may impair suitability for Class I,
Division 2.
- WARNING - EXPOSURE TO SOME CHEMICALS MAY DEGRADE THE SEALING PROPERTIES OF
MATERIALS USED IN THE FOLLOWING DEVICES: Sealed Relay Device.
- The Console port is for maintenance purposes only, and that it may only be used when the area is
known to be non-hazardous.
Condition for safe use:
- The devices are to be installed in an ATEX Certified IP54 enclosure in accordance with EN 60079-15
and accessible only by the use of a tool.