7
Electrical Connection and Security
1.
THIS APPLIANCE MUST BE EARTHED
2.
Your oven is adjusted in compliance with 230-240 Volt AC, 50 Hz
electrical supply, and requires a 16 Amp fuse (For B.S. 13 Amp.).
If the main supply is different from this specified value, contact an
electrician or your authorized service.
3.
Should you need to replace the 13 Amp plug top please ensure
you rewire the replacement plug as follows(For B.S.);
Figure–6
Brown
wire to the
Live
terminal
Blue
wire to the
Neutral
terminal
Yellow & Green
wire to
Earth
4.
Electrical connection of the oven should only be made using
sockets with Earth system installed (for England B.S. Approved
sockets with Earth system), and in compliance with Regulations. If
there is no proper socket with Earth in place, immediately contact
a qualified electrician. The Manufacturer will not be responsible for
damage or injuries that can arise because of inappropriate supply
outlets with no earth system.
5.
If your electric supply cable becomes damaged, it should be
replaced using 1 meter length of H05RR-F 3x1.5 mm² silicon
power cable by an authorized service engineer or qualified
electrician.
6.
The electrical supply cable should not touch the hot parts of the
appliance.
7.
The oven should be installed into an oven housing that provides
good upper and lower ventilation.
8.
This oven must be correctly installed and secured in place, in
accordance with manufacturer’s instructions and by a qualified
person.
9.
Make sure that the plug or isolation switch is accessible, so as not
to touch to hot parts.
10.
Never work on the oven while it is switched on. Maintenance and
service must be carried out after the power supply has been
disconnected.
Gas Connection and Security
1.
The appliance should be connected to the main gas supply or to a
gas cylinder in compliance with National regulations. Before
carrying out the connections, make sure the oven is compatible
with the gas supply you wish use.
2.
When using liquid gas from gas cylinder, install a pressure
regulator that complies with current National regulations.
3.
Check that the pressure of the gas supply is consistent with the
values indicated in Table- (Burner and nozzle specifications) since
this will ensure the safe operation and longevity of your appliance
while maintaining efficient energy consumption.