3 Connection
-
7
-
2.
Loosen the screws affixing the cable clamp, and remove the cable clamp.
3.
Connect the protective earth conductor only when the controller is an
ESMC-A
,
ESMC-C
.
Protective earth wire
: AWG16 (1.25 mm
2
)
: Sheath outer diameter Ø2.4 mm or less
9.5 mm
(0.37 in.) max.
Ø4.1 mm (0.16 in.) or more
Bare crimp terminal (round)
M4
Tightening torque: 1.0 to 1.3 N·m
(142 to 184.6 oz-in)
Protective
earth wire
4.
Connect the motor cable leads to the motor connectors in the order of a and b.
Motor cable (sold separately)
a
b
Note
Insert the two connectors until the lock levers are securely affixed.
5.
Connect the protective earth wire and motor cable using the cable clamp removed in step 2.
Tightening torque: 0.6 N·m (85.2 oz-in)
Hook
6.
Install the end plate by paying attention not to pinch the protective earth wire and motor cable,
and affix the end plate with the affixing screws.
Tightening torque: 0.6 N·m (85.2 oz-in)