background image

6

EN

MAINTAINANCE

Maintain the Rain Gauge
Clean the hole of the rain collector and the debris collector for maintaining accuracy is 

very important. Unscrew  the debris collector and clean the dirt by water periodically.

Maintain the Wind Sensor
If the wind cup doesn’t spin in the wind or does not spin as fast as they should.
Remove the wind cup and clear out all bugs, spider webs or debris.

NOTE

 Do not apply any fluid lubricant on the shaft and bearing. It probably breaks 

the inner electronic components.

SPECIFICATIONS
BASE STATION

Dimension (L x W x H)

180 x 90 x 160 mm 

(7 x 3.54 x 6.3 inches)

Weight

427.5 g (0.94 lbs) without battery

Battery

   4 x 1.5 V AA batteries

AC/DC Adaptor

Input: 100-240 V, 50-60 Hz 300 mA

Output: DC 5V, 1000 mA

ALL-IN-ONE SENSOR

Dimension (L x W x H)

385 x 195 x 315 mm

(15.16 x 7.68 x 12.4 inches)

Weight

1139 g (2.51 lbs) without battery

RF transmission frequency EU: 868mhz, US: 915mhz

No. of channel

3

RF transmission 

range  

250 - 300 m (internal antenna)

Transmission Cycle

15 seconds

Battery 

4 x 1.5 V AA + 4 x 1.5 V AA (optional for dust 

sensor)

Battery life

with dust sensor: 6 months (8 x 1.5 V AA)

without dust sensor: 12 months (4 x 1.5 V AA) 

BAROMETRIC PRESSURE

Unit

mb, inHg, mmHg and hPa

Measuring range

700 – 1050 hPa 

Accuracy

+/- 7 hP a

Altitude setting

Sea level 

User setting for offset pressure to sea level

Weather display

Sunny, Partly Cloudy, Cloudy,

Rainy and Snowy

INDOOR TEMPERATURE

Temperature unit

°C / °F (°C for EU, °F for US)

Measuring Range

-5  to 50 °C  (23 – 122 °F)

Accuracy

0 – 40 °C (32 – 104 °F): +/-1 °C (+/- 2 °F)

-5 to 0 °C (23 – 32.0 °F): +/-2 °C (+/- 4 °F)

40 – 50 °C (104 – 122 °F): +/-2 °C (+/- 4 °F)

Resolution

0.1 °C or 0.1 °F (remark: 0.1 °F convert from 

0.1 °C display)

Memory

Current, Min. and Max.

RELATIVE HUMIDITY

Measuring Range

25% - 90% RH

Accuracy

40% - 80%RH: +/-5% RH

25% - 40%RH and 80%- 90%RH: +/-7% RH

Resolution

1%

Memory

Current, Min and Max

OUTDOOR TEMPERATURE

Temp. unit

°C / °F  (°C for EU, °F for US)

Measuring Range

-30 to 60°C (-22 to 140°F)

Accuracy

-20 to 0 °C: +/-2.0°C (+/- 4.0°F)

0 – 40°C: +/-1.0°C (+/- 2.0°F)

40 – 50°C: +/-2.0°C (+/- 4.0°F)

50 – 60°C: +/- 3.0°C (+/- 6.0°F)

Temperature resolution 

0.1°C  (0.2°F)

Memory

Current, Min and Max

WIND SENSOR

Wind speed unit

m/s, knots, kph, mph

Speed accuracy

2 - 10 m/s (+/-2 m/s)
10 - 56 m/s (+/-10%)

Direction resolution

22.5 degree

Memory

Max wind speed

RAIN GAUGE

Rainfall unit

mm , inch (mm for EU, inch for US)

Rain rate unit

mm/hr and inch/hr

Measuring range for rainfall

0 mm to 9999 mm (0-393.6 inches)

Measuring range for rain rate

0, 0.04 in/hr (1mm/hr) to 

40 in/hr (1016 mm/hr)

Accuracy

0 - 15 mm (0 - 0.6”)/hr : +/- 1 mm/hr (0.04”)

15 - 991 mm/hr (0.6 - 39”) : +/- 10 %

Memory

Past 24 hrs, hourly from last memory reset

PRECAUTIONS

•  

Use only fresh batteries of the required size and type. Do not mix old and new 

batteries, different types of batteries.

•  

Do  not  dispose  old  batteries  as  unsorted  municipal  waste.  Collection  of  such 

waste separately for special treatment is necessary.

•  

If  you  do  not  plan  to  use  the  product  for  a  long  time,  remove  the  batteries. 

Batteries can leak chemicals that can damage electronic parts.

•   Do  not  subject  the  device  to  excessive  force,  shock,  dust,  temperature  or 

humidity.

•   Do not immerse the device in water. If you spill liquid over it, dry it immediately 

with a soft, lint-free cloth.

•   Do not clean the device with abrasive or corrosive materials.
•   Do not tamper with the device’s internal components. 

Doing so invalidates the 

warranty.

•   Images shown in this manual may differ from the actual display.
•   When  disposing  of  this  product,  ensure  it  is  collected  separately  for  special 

treatment.

•   The contents of this manual may not be reproduced without the permission of the 

manufacturer.

NOTE

  The  technical  specifications  for  this  product  and  the  contents  of  the  user 

manual are subject to change without notice.

NOTE

  Features  and  accessories  will  not  be  available  in  all  countries.  For  more 

information, please contact your local retailer. To download an electronic version of 

the user manual, please visit 

http://global.oregonscientific.com/customerSupport.php

.

ABOUT OREGON SCIENTIFIC

Visit our website 

www.oregonscientific.com to learn more about Oregon Scientific 

products.
For any inquiry, please contact our Customer Services at 

[email protected]

.

Oregon  Scientific  Global  Distribution  Limited  reserves  the  right  to  interpret  and 

construe any contents, terms and provisions in this user manual and to amend it, 

at its sole discretion, at any time without prior notice. To the extent that there is any 

inconsistency  between  the  English  version  and  any  other  language  versions,  the 

English version shall prevail.

EU-DECLARATION OF CONFORMITY

Hereby,  IDT  Technology  Limited,  declares  that  Professional  all-in-one  Weather 

Station (model: WMR500) is in compliance with the essential requirements and other 

relevant provisions of Directive RED 2014/53/UE. A copy of the signed and dated 

Declaration of Conformity is available on request via our Oregon Scientific Customer 

Service.

COUNTRIES RED APPROVAL COMPLIED

All EU countries, Switzerland  CH 

 

 

 

       and Norway    N

FCC STATEMENT

This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is  subject  to  the 

following two conditions: (1) This device may not cause harmful interference, and (2) 

This device must accept any interference received, including interference

  Changes  or  modifications  not  expressly  approved  by  the  party 

responsible for compliance could void the user’s authority to operate the equipment.

 This equipment has been tested and found to comply with the limits for a Class 

B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed 

to  provide  reasonable  protection  against  harmful  interference  in  a  residential 

installation.
This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does cause harmful interference 

to radio or television reception, which can be determined by turning the equipment 

off and on, the user is encouraged to try to correct the interference by one or more 

of the following measures:

•  Reorient or relocate the receiving antenna.
•  Increase the separation between the equipment and receiver.
•  Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

•  Consult the dealer or an experienced radio / TV technician for help.

DECLARATION OF CONFORMITY

The following information is not to be used as contact for support or sales. Please call 

our customer service number (listed on our website at 

www.oregonscientific.com

), or 

on the warranty card for this product) for all inquiries instead.

We

Name:   

Oregon Scientific, Inc.

Address:  

10778 SW Manhasset Dr.

 

 

DEVICE B-2 Tualatin,

 

 

Or 97062 USA

Telephone No.: 

1-800-853-8883

declare that the product 

Product No.: 

WMR500

Product Name: 

Professional all-in-one Weather Station

Manufacturer: 

IDT Technology Limited

Address:  

Block C, 9/F, Kaiser Estate,

 

      

Phase 1, 41 Man Yue St.,    

 

 

Hung Hom, Kowloon, 

 

 

Hong Kong

WMR500_EN R16.indd   6

2016/9/8   上午 9:36

Содержание WMR500

Страница 1: ...umidity 6 Wind sensor 6 Rain gauge 6 Precautions 6 About Oregon Scientific 7 EU Declaration Of Conformity 7 FCC Statement 7 Declaration of Conformity 7 Information for users 7 INTRODUCTION Thank you for selecting the Oregon Scientific Weather Station WMR500 This product can provide you with weather information through an all in one sensor with high levels of accuracy Download the dedicated app to ...

Страница 2: ...Clock Calendar Weekday Moon Phase area 1 Weather forecast 2 Wi Fi connection indicator 3 Bluetooth indicator 4 No main power supply 5 Low battery indicator for the sensor 6 Sensor searching indicator 7 Sensor channel 8 Selected area icon 9 Low battery indicator for the base station A Temperature Heat Index Humidity Dew point area 1 Selected area icon 2 Indoor Outdoor temperature reading C for EU F...

Страница 3: ...rection vane Takes wind direction 7 Dust sensor not included location Take PM 2 5 PM 10 readings 8 Temperature Humiditysensor notshown Measurestemperatureandhumidityreadings 9 SET NORTH Calibrate the direction of wind sensor 10 RESET Returns unit to default settings 11 Battery compartment for the all in one sensor 12 Temperature Humidity sensor location 13 Dust sensor location optional 14 Debris c...

Страница 4: ...you will be connecting more than one all in on sensor slide the channel switch CHANNEL 1 2 3 to select another channel before replace the battery compartment cover For longer performance recommend to use alkaline batteries and consumer grade lithium batteries in temperatures below freezing Replace the batteries when displays on the base station Press RESET after each battery replacement The power ...

Страница 5: ...hill area 2 Press MAX MIN to toggle between current MAX wind speed and current MIN wind chill readings NOTE The wind chill factor is based on the combined effects of temperature and wind speed UV RAINFALL BAROMETRIC PRESSURE PM The station is capable of displaying the UV index the current or last 24 hours of rainfall max rain rate barometric pressure and air quality readings RAINFALL To view the r...

Страница 6: ...on 22 5 degree Memory Max wind speed RAIN GAUGE Rainfall unit mm inch mm for EU inch for US Rain rate unit mm hr and inch hr Measuring range for rainfall 0 mm to 9999 mm 0 393 6 inches Measuring range for rain rate 0 0 04 in hr 1mm hr to 40 in hr 1016 mm hr Accuracy 0 15 mm 0 0 6 hr 1 mm hr 0 04 15 991 mm hr 0 6 39 10 Memory Past 24 hrs hourly from last memory reset PRECAUTIONS Use only fresh batt...

Страница 7: ...eclares that Professional all in one Weather Station model WMR500 is in compliance with the essential requirements and other relevant provisions of Directive RED 2014 53 UE A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service COUNTRIES RED APPROVAL COMPLIED All EU countries Switzerland CH and Norway N FCC STATEMENT This device ...

Отзывы: