6
EN
MAINTAINANCE
Maintain the Rain Gauge
Clean the hole of the rain collector and the debris collector for maintaining accuracy is
very important. Unscrew the debris collector and clean the dirt by water periodically.
Maintain the Wind Sensor
If the wind cup doesn’t spin in the wind or does not spin as fast as they should.
Remove the wind cup and clear out all bugs, spider webs or debris.
NOTE
Do not apply any fluid lubricant on the shaft and bearing. It probably breaks
the inner electronic components.
SPECIFICATIONS
BASE STATION
Dimension (L x W x H)
180 x 90 x 160 mm
(7 x 3.54 x 6.3 inches)
Weight
427.5 g (0.94 lbs) without battery
Battery
4 x 1.5 V AA batteries
AC/DC Adaptor
Input: 100-240 V, 50-60 Hz 300 mA
Output: DC 5V, 1000 mA
ALL-IN-ONE SENSOR
Dimension (L x W x H)
385 x 195 x 315 mm
(15.16 x 7.68 x 12.4 inches)
Weight
1139 g (2.51 lbs) without battery
RF transmission frequency EU: 868mhz, US: 915mhz
No. of channel
3
RF transmission
range
250 - 300 m (internal antenna)
Transmission Cycle
15 seconds
Battery
4 x 1.5 V AA + 4 x 1.5 V AA (optional for dust
sensor)
Battery life
with dust sensor: 6 months (8 x 1.5 V AA)
without dust sensor: 12 months (4 x 1.5 V AA)
BAROMETRIC PRESSURE
Unit
mb, inHg, mmHg and hPa
Measuring range
700 – 1050 hPa
Accuracy
+/- 7 hP a
Altitude setting
Sea level
User setting for offset pressure to sea level
Weather display
Sunny, Partly Cloudy, Cloudy,
Rainy and Snowy
INDOOR TEMPERATURE
Temperature unit
°C / °F (°C for EU, °F for US)
Measuring Range
-5 to 50 °C (23 – 122 °F)
Accuracy
0 – 40 °C (32 – 104 °F): +/-1 °C (+/- 2 °F)
-5 to 0 °C (23 – 32.0 °F): +/-2 °C (+/- 4 °F)
40 – 50 °C (104 – 122 °F): +/-2 °C (+/- 4 °F)
Resolution
0.1 °C or 0.1 °F (remark: 0.1 °F convert from
0.1 °C display)
Memory
Current, Min. and Max.
RELATIVE HUMIDITY
Measuring Range
25% - 90% RH
Accuracy
40% - 80%RH: +/-5% RH
25% - 40%RH and 80%- 90%RH: +/-7% RH
Resolution
1%
Memory
Current, Min and Max
OUTDOOR TEMPERATURE
Temp. unit
°C / °F (°C for EU, °F for US)
Measuring Range
-30 to 60°C (-22 to 140°F)
Accuracy
-20 to 0 °C: +/-2.0°C (+/- 4.0°F)
0 – 40°C: +/-1.0°C (+/- 2.0°F)
40 – 50°C: +/-2.0°C (+/- 4.0°F)
50 – 60°C: +/- 3.0°C (+/- 6.0°F)
Temperature resolution
0.1°C (0.2°F)
Memory
Current, Min and Max
WIND SENSOR
Wind speed unit
m/s, knots, kph, mph
Speed accuracy
2 - 10 m/s (+/-2 m/s)
10 - 56 m/s (+/-10%)
Direction resolution
22.5 degree
Memory
Max wind speed
RAIN GAUGE
Rainfall unit
mm , inch (mm for EU, inch for US)
Rain rate unit
mm/hr and inch/hr
Measuring range for rainfall
0 mm to 9999 mm (0-393.6 inches)
Measuring range for rain rate
0, 0.04 in/hr (1mm/hr) to
40 in/hr (1016 mm/hr)
Accuracy
0 - 15 mm (0 - 0.6”)/hr : +/- 1 mm/hr (0.04”)
15 - 991 mm/hr (0.6 - 39”) : +/- 10 %
Memory
Past 24 hrs, hourly from last memory reset
PRECAUTIONS
•
Use only fresh batteries of the required size and type. Do not mix old and new
batteries, different types of batteries.
•
Do not dispose old batteries as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
•
If you do not plan to use the product for a long time, remove the batteries.
Batteries can leak chemicals that can damage electronic parts.
• Do not subject the device to excessive force, shock, dust, temperature or
humidity.
• Do not immerse the device in water. If you spill liquid over it, dry it immediately
with a soft, lint-free cloth.
• Do not clean the device with abrasive or corrosive materials.
• Do not tamper with the device’s internal components.
Doing so invalidates the
warranty.
• Images shown in this manual may differ from the actual display.
• When disposing of this product, ensure it is collected separately for special
treatment.
• The contents of this manual may not be reproduced without the permission of the
manufacturer.
NOTE
The technical specifications for this product and the contents of the user
manual are subject to change without notice.
NOTE
Features and accessories will not be available in all countries. For more
information, please contact your local retailer. To download an electronic version of
the user manual, please visit
http://global.oregonscientific.com/customerSupport.php
.
ABOUT OREGON SCIENTIFIC
Visit our website
www.oregonscientific.com to learn more about Oregon Scientific
products.
For any inquiry, please contact our Customer Services at
.
Oregon Scientific Global Distribution Limited reserves the right to interpret and
construe any contents, terms and provisions in this user manual and to amend it,
at its sole discretion, at any time without prior notice. To the extent that there is any
inconsistency between the English version and any other language versions, the
English version shall prevail.
EU-DECLARATION OF CONFORMITY
Hereby, IDT Technology Limited, declares that Professional all-in-one Weather
Station (model: WMR500) is in compliance with the essential requirements and other
relevant provisions of Directive RED 2014/53/UE. A copy of the signed and dated
Declaration of Conformity is available on request via our Oregon Scientific Customer
Service.
COUNTRIES RED APPROVAL COMPLIED
All EU countries, Switzerland CH
and Norway N
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
This device must accept any interference received, including interference
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio / TV technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please call
our customer service number (listed on our website at
www.oregonscientific.com
), or
on the warranty card for this product) for all inquiries instead.
We
Name:
Oregon Scientific, Inc.
Address:
10778 SW Manhasset Dr.
DEVICE B-2 Tualatin,
Or 97062 USA
Telephone No.:
1-800-853-8883
declare that the product
Product No.:
WMR500
Product Name:
Professional all-in-one Weather Station
Manufacturer:
IDT Technology Limited
Address:
Block C, 9/F, Kaiser Estate,
Phase 1, 41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
WMR500_EN R16.indd 6
2016/9/8 上午 9:36