background image

Lubrication

The vacuum cleaner motor bearings are factory lubricated and sealed.
Further lubrication is not required.

General Cleaner Care

At least once a month, check for
and remove excessive lint, string or
hair from revolving brush.

Wipe the outside of the cleaner with
a damp cloth. Also clean the
connector deflector assembly area,
base of cleaner and fan housing
area. If there is dust in the outer
bag, vacuum it or shake it out.

A little preventative maintenance will
keep your cleaner looking new and
will ensure continued cleaning effec-
tiveness.

CAUTION—Wood Floors, Soft (Vinyl, Asphalt Tile, etc.) Floor
Surfaces and Polished Floor Finishes

Use floor and floor finish manufacturer’s recommended methods of
cleaning. The metal strip on the base of the cleaner could be damaged
if used on concrete or abrasive surfaces, and, therefore, cause damage
to wood floors, soft (vinyl, asphalt tile, etc.) floor surfaces and polished
floor finishes. The roller brush may also scuff very soft finishes.

To Replace Filter Dust Bag

WARNING: Unplug cord from electrical
outlet before servicing.

Bag Removal:

fig. 6

Unzip outer bag completely.

fig. 7

Pull bag cardboard collar to release bag dock door from
connector. Bag dock door will hinge downward.

fig. 8

Gently pull bag cardboard collar upward out of the bag dock.
Dust seal will close automatically.

Bag Installation:

fig. 9

Slide the cardboard collar completely onto bag dock door.

fig. 10 Firmly push bag dock door with both thumbs on indication point

until it snaps.

How to Replace a Worn Belt

WARNING: Unplug cord from electrical
outlet before servicing.

fig. 11 Remove the replacement belt from the storage channel.

fig. 12  Remove the door by removing the hold down screw located on

side of power head.

fig. 13 Slide the door forward by prying open with a screwdriver or coin.

fig. 14 Remove the belt from the motor drive shaft and brush roll pulley.

fig. 15 Loop the new belt over the motor drive shaft. Place the

opposite end of the belt on the brush roll pulley. Rotate the
brush roll three (3) complete revolutions to ensure that no part
of the belt is overhanging the end of the motor drive shaft.

fig. 13 Replace the door by sliding it into the groove at the bottom of

the housing.

fig. 12 Replace the hold down screw and tighten.

To Adjust or Replace Brush

WARNING: Unplug cord from electrical
outlet before servicing.

fig. 16 To determine if the brush is worn, place a firm straight edge

across the nozzle opening. If brush bristles do not extend
beyond baseplate, brush should be adjusted.

fig. 17 Remove the baseplate by removing 5 screws. 

fig. 18 Remove the belt and brush roll from the housing.

fig. 19 Rotate both bearing assemblies at ends of brush roll to show

"OLD" and replace in the holding channels in the housing. 

NOTE: The bearing assembly setting marked "OLD" is smooth on the
top of the assembly. The one marked 

"NEW" is notched. When rotating

bearings, make sure both bearing assembly settings are the same and
face up when replacing the brush roll.

fig. 16 Reassemble the belt and the baseplate and check bristle height

above baseplate at each end of brush.

If a previous adjustment has already been made and bristle height does
not extend above baseplate, a new brush assembly should be ordered.

IMPORTANT: Unless the brush is worn as indicated above, both
bearings must be in the new position. When rotating, both
bearings must be in the old position. Unmatched settings will
cause damage to your machine.

Using An Oreck Fresh Air

®

Tab

fig. 20 Your ORECK XL vacuum cleaner has a special ORECK FRESH

AIR

®

tab pocket. This pocket is located inside the outer bag in

the area where the disposable paper bag attaches to the intake
tube. Insert tablet in pocket if desired.

Bulb Replacement (

For units with lights):

WARNING: Unplug cord from electrical
outlet before servicing.

fig. 21 Remove lamp housing by removing two (2) screws in the top of

the lamp housing. Pull burned out bulb from holder and replace
with new bulb. Use only Oreck replacement parts. Replace
lamp housing by replacing two screws in the top of the lamp
housing.

Stuffing or Blockage

IMPORTANT: On plush and new carpets, stuffing may occur inside the
the intake tube and the lower tube assembly. This is due to excessive fuzz
and loose cuttings in the carpet. Stuffing could occur for the first few
cleanings until all the loose material is removed. Due to the high efficiency
of the cleaner, many older carpets will cause stuffing when the cleaner is
first used on them. If your vacuum cleaner does not pick up properly, or
makes unusual noise and the outer bag does not fluff up or balloon open,
follow these steps:

WARNING: Unplug cord from electrical
outlet before servicing.

fig. 22 Check for blockage at the mouth of the intake opening. If there

is blockage, remove it with long-nose pliers, a screwdriver or
wire coat hanger. If you can not reach the blockage, remove
baseplate 

(fig. 23).

fig. 24 If the blockage is not at the base, remove lower tube. Unhook

retainer spring, releasing bottom of bag. 

Twist lower collar counterclockwise to slide up. Pull tube out of
base.

fig. 25 Check for blockage. If blockage is in the tube, remove with a

coat hanger.

fig. 26 If tube is not blocked, look into fan housing. Remove debris

with long-nose pliers, a screwdriver or coat hanger.

fig. 27 To reassemble, check O-ring on tube, and replace if damaged.

Vacuum will not operate properly without the tube O-ring. Slide
O-ring to approximately 2" from base of tube. Replace tube by
first lining up slot at base of tube with inner tab inside fan
housing. Then reinsert tube and push down until the tube is
seated. Make sure O-ring is in place against fan housing
opening. Replace and tighten collar until collar locking tabs are
locked in place. 

fig. 28 Make sure collar is not cross threaded on housing. Reattach

bag spring 

(fig. 24).

fig. 29 Many times blockage occurs due to a full dust bag causing dirt 

to back down the air flow system. When that happens, the 
blockage will be at the top of the system, starting in the area 
where the dust bag connects to the connector assembly.

NOTE: If the above actions do not correct the problem, contact an
Oreck authorized service center or call the customer service center.
USA: 1-800-989-3535   Canada: 1-888-676-7325

6

Содержание XL2330HS

Страница 1: ...Z I N G Includes Safety Warnings Warranty Operating Instructions Trouble Diagnosis Accessories USA 1 800 989 4244 CANADA 1 800 393 8801 VISIT ONE OF OUR OVER 450 STORE LOCATIONS USA 1 800 989 3535 CANADA 1 888 676 7325 COMMERCIAL 1 800 242 1378 www oreck com www oreckcommercial com VISIT ONE OF OUR OVER 450 STORE LOCATIONS 75690 02 REV C ...

Страница 2: ...OLD NEW ç Intake Opening 2 1 2 3 6 7 11 12 13 14 15 20 17 18 8 16 23 24 Intake Opening Fan Housing O ring 19 Fan Housing Tube 4 5 21 22 27 Connector Deflector Opening 25 26 9 10 11 Retainer Spring 28 29 ...

Страница 3: ...ACUUM CLEANER WARNING To reduce the risk of fire electric shock or injury IMPORTANT SAFETY INSTRUCTIONS Do not leave appliance unattended when plugged in Unplug from outlet when not in use and before servicing Do not use outdoors or on wet surfaces Do not operate the unit while in the upright and locked position Do not let the unit run while in any one stationary position for any period of time Ke...

Страница 4: ...ation with the sale of this product Oreck s limited warranty is valid only if you retain proof of purchase from Oreck or an Oreck Authorized Retail Dealer for this product If you purchase this product from any other source your purchase is AS IS which means Oreck grants you no warranty and that you not Oreck assume the entire risk of the quality and performance of this product including the entire...

Страница 5: ...ll pick up pins paper clips and other small objects it is recommended that these be removed from the floor before you vacuum Failure to do so may result in permanent damage to the motor suction fan and its housing 5 WARNING Do not use your vacuum cleaner on damp or wet surfaces This will cause damage to the vacuum cleaner and is dangerous to the user Damage caused by use on wet or damp surfaces is...

Страница 6: ...e belt and the baseplate and check bristle height above baseplate at each end of brush If a previous adjustment has already been made and bristle height does not extend above baseplate a new brush assembly should be ordered IMPORTANT Unless the brush is worn as indicated above both bearings must be in the new position When rotating both bearings must be in the old position Unmatched settings will ...

Страница 7: ...7 ...

Страница 8: ...690 02 REV C 2005 Oreck Holdings LLC All rights reserved All word marks logos product configurations and registered trademarks are owned 11 05 ECN R 8193 and used under the authority of Oreck Holdings LLC ...

Отзывы: