Operating instructions REB 6, REB 14, REB 20
9 What to do if ...?
orbitalum tools
gmbh
(06.10)
MT_REB 6_REB 14_REB 20_BA_04_790093762_02.doc
31
9
What to do if ...?
9.1
General trouble shooting
In the following table you will find possible causes of faults and the appropriate
remedies.
Problem Possible
cause
Remedy
REB (D) does not run
even though connected
to the compressed air
line.
Compressed air motor blades in the
wrong position.
Set the throttle valve to maximum
speed, then switch on and
gradually decrease.
Plates are stuck in the rotor.
Unscrew the REB (D)’s pressure
regulator and put in thin-viscosity
oil, then reconnect the
compressed air supply.
Dismantle the compressed air
motor and clean the plates.
System pressure too low.
Increase the system pressure to
6 bar.
Motor of the REB (D)
does not deliver the
performance required.
Pressure in the primary network is too
low (under 6 bar).
Disconnect other consumers from
the network.
Increase system pressure to
6 bar.
Tool (multifunctional
tools (MFW)) catches
during preparing.
Too much feed.
On the REB (D):
Turn off the machine, disconnect
the compressed air supply, and
loosen the pipe clamping.
On the REB (D) and (E):
Turn back the machine counter-
clockwise approx. 5 mm.
Detach the tool holder and
remove the machine from the
pipe.
Remove chip using side-cutting
pliers and file off the shoulder.
Feed carefully for further
machining.
Multifunctional tool is loosen.
Tighten the multifunctional tool.
Motor of the REB (E)
cuts out of its own
accord.
Maximum permissible operating
temperature has been exceeded.
Switch off the REB (E), allow to
cool down and then switch on
again.
Maximum permissible power
consumption has been exceeded.
Switch off the REB (E) and then
on again.
Содержание REB 14