![Orbitalum 852 000 001 Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/orbitalum/852-000-001/852-000-001_translation-of-original-operating-instructions_1648239103.webp)
(14.01.21) OW_ORBIMAT_300SW_BA_852060202_00_EN
ORBITALUM TOOLS GMBH
,
D-78224 SINGEN, WWW.ORBITALUM.COM, PHONE +49 (0) 77 31 792-0 103
ORBIMAT 300 SW
EnGLISH
8. OPERATION
8.1
Auto programming
8.1.1
Setting parameters
1. Connect the weld head.
2. Switch on the machine.
The main menu appears in the display.
3. Select and highlight the "
Auto programming
" menu item.
The following display appears:
Field "....":
Return to main menu.
Fields "
Weld head model
" to "
Wall thickness
":
Parameter entry.
Field "
Wire feed
":
Welding with/without filler wire.
"
Calculate program
":
Calculation of the procedure with the entered parameters.
Abb. 3:
Sub menu – Auto programming
8.1.2
Configuring weld head
1. Select the "
Weld head
" field and briefly press the rotary knob.
The following display appears:
A list of the weld heads which can be used with this sys-
tem appears.
This system automatically detects the type of connected
head and offers it for selection first. In the example, this
is an DVR 50.
Selecting a weld head