DESCRIPTIÓN: 

The NEO ML+ thermostat is a user-friendly, adjustable digital electronic 
thermostat.  

 
WARNING:

  

Electrical appliance assembly and installation must be carried out by an 
authorised installer. Before connecting to the mains, the power must be 
removed from the associated wiring.  
This appliance is internally protected against interference. 

 
INSTALLATION:  

The control device is independently mounted on a wall or in a 
mechanism box.  It is recommended that it be installed at a height of 1.5 
metres. 
The thermostat must be independently installed so that it free from 
obstacles and is not affected by other appliances or heat sources (the 
sun, radiators and windows etc). 

 

To fix the device in place, open the cover and slide the battery 
compartment cover to the right. Remove the securing base by pressing 
on the tab in the battery compartment and separate it from the 
appliance. Secure the base with the included screws. In order to replace 
the NEO ML+ into its base, insert the upper base guides into the slots in 
the apparatus and press on the lower part until the tab fits into the space 
under the battery compartment cover. Replace the battery compartment 
cover. 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

CONNECTION:  

Connect the device as shown in the diagram below: 
 
 
 
 
 
 

 
 

FITTING AND REPLACING BATTERIES: 

 

 

The device is powered by two 1.5 V LR03 (AAA) alkaline batteries (not 
included). Respect the polarity indicated inside the battery compartment. 
When batteries are inserted for the first time, the screen should activate 
and all display segments should appear. Battery lifetime is approximately 
one year. 
When battery power is running low, the symbol 

Lo is displayed 

alternating with measured ambient temperature.

 The batteries should be 

changed as soon as possible for continued correct operation NEO ML+ 
operation. 

 

Used batteries should be disposed of in a special used-battery container. 
Respect the environment.  

 
OPERATING MODES: 

 

This equipment automatically detects the operating mode in accordance 
with how the configuration jumpers are inserted and whether an external 
sensor is connected. 
The configuration jumpers are inserted over the pins located at the rear 
of the apparatus. The external sensor is connected to terminals 1 and 2. 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

IMPORTANT: It is necessary to RESET the device after changing 
the configuration

. To RESET the device, it must be connected to the 

base .It is necessary to press the Reset button for more than 3 seconds. 
 

-  INCORRECT CONFIGURATIONS. 

- If the internal or external sensor is not fitted the following will be 

displayed on screen 

--  --

. Incorrect sensor operation. 

 

-  If the external sensor is connected and Air-conditioning, the screen will 

display 

Err

, since this operation is invalid.

 

 
- HEATING-COOLING MODES 

 

When the programming jumper is set to HEAT the thermostat is 
operating in heating mode. When the load is active, this symbol

 will 

appear on the display.

 

 When the programming jumper is set to COOL the thermostat is 
operating in cooling mode. When the load is active, this symbol o will 
appear on the display.  

 

IMPORTANT NOTE: In cooling mode, there is a three-minute load-
activation delay. 
 
If neither of the HEAT / COOL jumpers is inserted, the thermostat 
remains in the switched-off mode, without any functions. 
 

- MODO NORMAL MODE (internal sensor) 

 

This mode is configured when the internal sensor jumper is fitted and no 
external sensor is connected. This mode is valid for both heating and 
cooling. 

 

The following symbol is displayed on the screen when Normal Mode is 
activated: 

 
The ambient temperature corresponds to the 
temperature measured by the internal sensor. 
 

In order to enter parameter configuration in 

Normal Mode

, press the 

 

and

 

 buttons at the same time for five seconds. 

Set

 

ºC

, will appear 

flashing on the screen, the 

 and

 

 buttons are used to choose 

equipment operation in either 

º F

 or 

º C

. Confirm with 

OK

.  

 

 The symbol     will now flash on the screen. Use the 

 

 buttons to 

select the 

COMFORT

 temperature. Confirm with 

OK

 

The symbol      will now flash on the screen. Select the 

ECO

 temperature 

with the 

 

 buttons. Press 

OK

.  

 

The word 

Diff.

 will start flashing on the screen. Use the 

 

 buttons to 

select the differential (the difference between the Switch On and Switch 
Off temperatures) between 0.2 ºC and 1 ºC, in 0.2 

°

C intervals. 

This mode has an anti-icing temperature set at 5 ºC, which only takes 
effect when the thermostat is switched to Standby      . 
 

1

2

3

4

5

EXTERNAL SENSOR

HEATING/COOLING

COVER

ON / OFF / OK

 

CONFORT

 

ECO  Tª

BATTERY

COMPARTMENT COVER

REDUCE

INCREASE

RESET

 ECO 

 

 CONFORT

 

INTERNAL SENSOR

EXTERNAL SENSOR

COOLING

HEATING

OFF

MANUAL ADJUSTMENT

CONFIGURATION

JUMPER PINS

INTERNAL SENSOR

COOLING

HEATING

INTERNAL SENSOR

Содержание NEO ML+

Страница 1: ...i n del equipo Para realizar un RESET el aparato debe estar conectado a la base y presionar el bot n de RESET durante mas de 3 segundos CONFIGURACIONES ERR NEAS Si el puente de sonda interna no est co...

Страница 2: ...continuaci n parpadea en pantalla las palabras Hi Limits junto con el s mbolo de Sonda Externa Con las teclas o se selecciona la temperatura l mite superior a la que el equipo desconectar la carga cua...

Страница 3: ...1 and 2 IMPORTANT It is necessary to RESET the device after changing the configuration To RESET the device it must be connected to the base It is necessary to press the Reset button for more than 3 s...

Страница 4: ...K The words Hi Limits will start flashing on the screen together with the External Sensor symbol The buttons are used to select the upper temperature limit at which the equipment will drop the load wh...

Страница 5: ...de l equipe Pour realiser un RESET l appareil doit etre connecte a la base et on doit faire pressione sur le bouton de reset pour une duree superieure de 3 secondes CONFIGURATIONS ERRON ES Si le pont...

Страница 6: ...mits clignotent alors l cran avec le symbole de Sonde Externe l aide des touches et s lectionnez la temp rature limite sup rieure laquelle l quipement d connectera la charge lorsque la sonde externe a...

Страница 7: ...die Klemmen 1 2 angeschlossen WICHTIG Nach nderung der Konfiguration des Ger tes ist ein RESET notwendig Um ein RESET auszuf hren muss das Ger t an der Basis angeschlossen sein und dann die RESET Tas...

Страница 8: ...hlen wir die obere Temperaturgrenze bei der das Ger t die Last abschaltet wenn der externe Sensor diese Temperatur erreicht je nach dem welches Material f r den Fu boden benutzt wurde kann diese Begr...

Отзывы: