11
EN
INSTALLATION
35
40
45
50
55
60
65
70
75
80
85
0
5
10
15
1
84
�0
2�
02
�0
04
5
x Temperature settings in °C
y Duration in min
15.4
Country-specific approvals and certifications
The test symbols can be seen on the type plate.
15.5
Extreme operating and fault conditions
In the case of faults, a peak temperature up to 100 °C may briefly occur in the system.
15.6
Data table
Oras 5
234013
Electrical data
Rated voltage
V
230
Rated output
kW
2,0
Rated current
A
8,7
Fuse/MCB rating
A
10
Frequency
Hz
50/60
Phases
1/N/PE
Hydraulic data
Mixed water volume 40 °C
l
10
Nominal capacity
l
5
Application limits
Max. flow rate
l/min
5
Max. permissible pressure
MPa
0
Values
Temperature setting range, DHW
°C
35-85
Versions
Undersink installation
X
Open vented type
X
Casing material
PS
Internal cylinder material
PP
Thermal insulation material
EPS
IP rating
IP24
Colour
White
Dimensions
Height
mm
420
Width
mm
252
Depth
mm
215
Weights
Weight
kg
3
313989_Oras_5_en_fi_sv_no_da.indb 11
24.03.2014 14:20:45