background image

Mktg Part Number Description

7103911

300GB 10Krpm, SAS-2, 2.5

"

HDD

7103912

900GB 10Krpm, SAS-2, 2.5

"

HDD

7103915

73GB SSD SAS-2, 2.5

"

Write Flash

Accelerator

7103917

Filler Panel, Drive Enclosure DE2-24P

Oracle Storage Drive Enclosure DE2-24C

Mktg Part Number Description

7103914

Drive Enclosure DE2-24C Base Chassis

7103913

3TB 7.2Krpm, SAS-2, 3.5

"

HDD

7103916

73GB SSD XATO SAS-2, 2.5

"

(2.5

"

to 3.5

"

Drive Adapter)

7103918

Filler Panel, Drive Enclosure DE2-24C

Sun Disk Shelf (DS2)

Mktg Part Number

Description

DS2-0BASE

Sun Disk Shelf (DS2) 24x3.5

"

SAS-2

DS2-HD2T

2TB 7.2Krpm, SAS-2, 3.5

"

HDD

7101765

3TB 7.2Krpm, SAS-2, 3.5

"

HDD

7101274

300GB 15Krpm, SAS-2, 3.5

"

HDD

7101276

600GB 15Krpm, SAS-2, 3.5

"

HDD

7101197

73GB SSD XATO, 3.5

"

DS2-LOGFILLER Sun Disk Shelf (DS2) 24x3.5

"

, LOGFiller

DS2-4URK-19U

Disk Shelf Rail Kit

Shelf

Oracle ZFS Storage Appliance Installation Guide • January 2014 E48491–02

78

Содержание ZFS

Страница 1: ...Oracle ZFS Storage Appliance Installation Guide Part No E48491 January 2014 E48491 02 ...

Страница 2: ... sous licence et soumis à des restrictions d utilisation et de divulgation Sauf disposition de votre contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer exécuter publier ou afficher le logiciel même partiellement sous quelque forme et par quelque procédé que ce soit Par ailleurs il est interdit de procéder à toute ...

Страница 3: ...ons 18 Internal Components 18 Motherboard Memory and PCIe Cards 20 Optional Cable Management Arm 24 Attached Storage 25 ZS3 4 25 ZS3 4 Hardware Overview 25 Controller Overview 25 Internal Boards 28 Components 29 Attached Storage 35 7120 35 7120 Hardware Overview 35 Chassis Overview 35 Electrical Specifications 38 Internal Components 38 Standalone Controller Configurations 44 Attached Storage 45 3 ...

Страница 4: ...ation 79 Installation 79 Overview 80 Precautions 80 Prerequisites 80 Controller Cabinet and Disk Shelf Installation Tasks 81 ZS3 2 Controllers 81 ZS3 2 Controller Installation Tasks 81 Prerequisites 81 Tools and Equipment Needed 82 Tasks 82 ZS3 4 Controllers 93 ZS3 4 Controller Installation Tasks 93 Prerequisites 94 Tools and Equipment Needed 94 Tasks 94 7x20 Controllers 104 7x20 Controller Instal...

Страница 5: ...r Configurations 140 DE2 to ZS3 2 7120 7320 Standalone 141 Connecting ZS3 2 7120 7320 Standalone Controllers to Disk Shelves 141 DE2 to ZS3 2 7320 Clustered 142 Connecting ZS3 2 7320 Clustered Controllers to Disk Shelves 142 DE2 to ZS3 4 7420 Standalone 144 Connecting the ZS3 4 7420 Standalone Controller to Disk Shelves 3 HBAs 144 DE2 to ZS3 4 7420 Clustered 146 Connecting the ZS3 4 7420 Clustered...

Страница 6: ...ers to Mixed Disk Shelves 157 ZS3 4 7420 with DE2 and Sun Disk Shelves 158 Connecting ZS3 4 7420 Standalone Controllers to Mixed Disk Shelves 158 ZS3 4 7420 Clustered with DE2 and Sun Disk Shelves 159 Connecting ZS3 4 7420 Clustered Controllers to Mixed Disk Shelves 159 4 Powering On and Configuring the System 161 Power 161 Powering On and Configuring the Appliance 161 Tasks 162 Next Steps 164 Ini...

Страница 7: ...ok This guide is for users and system administrators who install and use the Oracle ZFS Storage Appliance Related Documentation Refer to the following documentation for administration information hardware overviews service procedures and software update notes Administration Guide Analytics Guide and Service Manual http www oracle com technetwork documentation Access to Oracle Support Oracle custom...

Страница 8: ...8 ...

Страница 9: ... family of products provides efficient file and block data services to clients over a network and a rich set of data services that can be applied to the data stored on the system Controllers ZS3 2 ZS3 4 7120 7320 7420 Expansion Storage Disk Shelves 1 C H A P T E R 1 9 ...

Страница 10: ...protocols you can configure your Oracle ZFS Storage system using the built in collection of advanced data services including LICENSE NOTICE Remote Replication and Cloning may be evaluated free of charge but each feature requires that an independent license be purchased separately for use in production After the evaluation period these features must either be licensed or deactivated Oracle reserves...

Страница 11: ...tack RAID 6 double and triple parity and optional RAID 6 across disk shelves Active active clustering for high availability Link aggregations and IP multipathing for network failure protection I O Multipathing between the controller and disk shelves Integrated software restart of all system software services Phone Home of telemetry for all software and hardware issues Lights out Management of each...

Страница 12: ...ly if you are not sure what to type in any given context pressing the Tab key will provide you with possible options Throughout the documentation pressing Tab is presented as the word tab in bold italics Help is always available the help command provides context specific help Help on a particular topic is available by specifying the topic as an argument to help for example help commands Available ...

Страница 13: ...rt 4x4 SAS 2 6Gb s external Refer to http www oracle com us products servers storage storage nas overview index html http www oracle com us products servers storage storage nas overview index html for the most recent component specification Front Panel The ZS3 2 controller drive slots and front panel components are shown in the following figure Drive slots 0 and 1 have two mirrored 900GB SAS 2 boo...

Страница 14: ... the following figure Figure Legend 1 SAS 2 HBA slot 1 7 AC power supplies PS1 top PS0 bottom 13 Alarm port DB 15 connector 2 4x4 SAS 2 HBA slot 2 8 System status LEDs 14 16 Cluster I O ports 3 PCIe slot 3 9 USB 2 0 ports 17 10 Gbit Ethernet ports 4 PCIe slot 4 10 SP 15 pin VGA video port 18 Chassis ground post 5 PCIe slot 5 11 Serial management port 6 PCIe slot 6 12 Network management port Note T...

Страница 15: ... 10 Gigabit Ethernet 10GbE network connectors labeled NET 3 NET 2 NET 1 and NET 0 left to right on the rear panel The ports operate at 100 Mbits sec 1000 Mbits sec or 10 Gbits sec Use these ports to connect the appliance to the network The LEDs located above each NET port are Link Activity left and Speed right indicators for each port as described in this table ConnectionType EEETerminology Speed ...

Страница 16: ...form a cluster see the Cluster configuration topic Removing RJ 45 Cables from Cluster Serial Ports CAUTION When disconnecting an RJ 45 cable from a cluster serial port 0 and 1 use extreme care not to damage the internal RJ 45 receptacle To properly remove an RJ 45 cable from a cluster serial port do the following 1 Using your index finger press down fully on the RJ 45 release tab Be sure the tab i...

Страница 17: ... 18 70 kg Electrical Specifications The ZS3 2 controller electrical specifications are listed below The power dissipation numbers listed are the maximum rated power numbers for the power supply The numbers are not a rating of the actual power consumption of the appliance Connectors Two C13 connectors which work on 110 220v outlets Input Nominal frequencies 50 60Hz 47 to 63 Hz range Nominal voltage...

Страница 18: ... available whenever the system is receiving AC input power even when the system is turned off Power Distribution Board The power distribution board distributes main 12V power from the power supplies to the rest of the controller It is directly connected to the connector break out board and to the motherboard through a bus bar and ribbon cable It also supports a top cover interlock kill switch The ...

Страница 19: ...is FRU 7 Top cover 11 USB board FRU 4 LED board FRU 8 PDB signal cable FRU 12 Power supplies Internal Cables The ZS3 2 controller contains the following field replaceable unit FRU internal cables FRUs are not customer serviceable and must be replaced by trained Oracle service technicians ZS3 2 Chapter 1 Introduction 19 ...

Страница 20: ...and PCIe Cards The ZS3 2 controller motherboard memory and PCIe components are described in the following figure and legend Note Field replaceable components FRUs are not customer serviceable and must be replaced by trained Oracle service technicians ZS3 2 Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 20 ...

Страница 21: ...PCIe Risers FRU 10 PDB duct 3 Motherboard FRU 7 PCIe cards 11 Power distribution board FRU 4 DIMMs 8 USB flash drive CPU and Memory The ZS3 2 controller motherboard has 16 slots in two groups that hold industry standard DDR3 low voltage LV DIMMS ZS3 2 Chapter 1 Introduction 21 ...

Страница 22: ...isted below Component Description FRU CRU Part Number CPU Intel E5 2658 2 1G 8 core FRU 7019701 Memory DIMM 16GB DDR3 1600 2Rx4 1 35V CRU 7041603 NIC HBA Options The following table describes the NIC HBA options for the ZS3 2 controller See PCIe Options for slot allocations Mktg Part Number Description SG SAS6 INT Z 8 port 6Gb s SAS 2 internal HBA SG XPCIE2FC QF8 Z 2 port 8Gb FC HBA ZS3 2 Oracle Z...

Страница 23: ...ins slots 1 and 4 Riser 2 contains slots 2 and 5 Riser 3 contains slots 3 and 6 PCIe Options The following table describes the supported PCIe configuration options for the ZS3 2 controller Slots 1 and 2 are reserved for internal and external HBAs as shown in the following table When adding PCIe cards populate from higher order slots 6 first toward lower order slots Note Any empty PCIe slots must h...

Страница 24: ...1 4325 02 2 port 8Gb FC HBA 4 Optional FC target or initiator backup 4 6 7023303 2 port 16Gb universal FC FCoE HBA 2 Optional FC target or initiator backup 4 6 375 3696 01 2 port InfiniBand CX2 HCA 2 Optional recommended front end 4 6 7051223 2 port 10GbE optical NIC 2 Optional recommended front end 4 6 7070006 2 port 10GbE copper NIC 2 Optional recommended front end Optional Cable Management Arm ...

Страница 25: ...3 4 ZS3 4 Hardware Overview Use the information on this page as a preparation reference for servicing replaceable components of the Oracle ZFS Storage ZS3 4 controller Refer to the following topics for procedural instructions Controller Tasks replace system controller components Disk Shelf Tasks replace disk shelf components Controller Overview The ZS3 4 controller can be configured as a single co...

Страница 26: ... 3 cm 5 25 in Depth 70 6 cm 27 8 in Width 43 7 cm 17 19 in Weight 16 36 kg 96 lbs Front Panel Figure Legend 1 Locator LED and button white 9 USB 2 0 Connectors 2 Service Required LED amber 10 DB 15 video connector 3 Power OK LED green 11 Boot drive 0 4 Power button 12 Boot drive 1 required 5 Service Processor SP OK LED green 13 Solid state drive 2 optional 6 Fan CPU Memory Service Required LED 14 ...

Страница 27: ...s are not depicted in this illustration Figure Legend 1 Power supply unit 0 status LEDs OK green Power Supply Fail amber AC OK green 8 Network NET 10 100 1000 ports NET0 NET3 2 Power supply unit 0 AC inlet 9 USB 2 0 ports 3 Power supply unit 1 status LEDs OK green Power Supply Fail amber AC OK green 10 PCIe slots 5 9 4 Power supply unit 1 AC inlet 11 Network management NET MGT port 5 System status...

Страница 28: ...onmental The SP controller draws power from the host s 3 3V standby supply rail which is available whenever the system is receiving AC input power even when the system is turned off Power Distribution Board The power distribution board distributes main 12V power from the power supplies to the rest of the system It is directly connected to the Vertical PDB card and to the motherboard through a bus ...

Страница 29: ...cator for Power Activity Fault and Locate Components The components of the ZS3 4 controller are shown in the following figure and identified in the legend Figure Legend 1 Motherboard 7 CPUs and heatsinks 2 Low profile PCIe cards 8 Memory risers 3 Power supplies 9 Fan board 4 Power supply backplane 10 Fan modules 5 Drive backplane 11 Boot drives and SSDs 6 System lithium battery ZS3 4 Chapter 1 Int...

Страница 30: ...service label on the cover for DIMM placement information On every memory riser slots D0 D2 D4 and D6 must be populated optionally slots D1 D3 D5 and D7 may be populated as a group on all installed memory risers All DIMMs in the system must be identical ZS3 4 Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 30 ...

Страница 31: ... Action Required TOP LED on the front of the server Fan Fault LED on or adjacent to the faulty fan module The system Overtemp LED might light if a fan fault causes an increase in system operating temperature NIC HBA Options This table describes NIC HBA PCIe card options for ZS3 4 standalone and cluster configurations Mktg Part Number Description SG SAS6 INT Z 8 port 6Gb s SAS 2 internal HBA SG XPC...

Страница 32: ... NET MGT is an RJ 45 connector and provides a LAN interface to the SP console There are four RJ 45 Gigabit Ethernet connectors NET0 NET1 NET2 NET3 located on the motherboard that operate at 10 100 1000 Mbit sec These network interfaces must be configured before use PCIe Options This table describes the PCIe base configuration and optional slot assignments for ZS3 4 standalone and cluster configura...

Страница 33: ...opper NIC 4 Optional recommended front end 3 375 3696 01 2 port Infiniband CX2 HCA 4 Optional recommended front end 3 7070195 4 port 1GbE copper NIC UTP 4 Optional recommended front end 3 7051223 2 port 10GbE optical NIC 6 Optional recommended front end 3 371 4325 02 2 port 8Gb FC HBA 4 Optional FC target or initiator backup 4 7070006 2 port 10GbE copper NIC 4 Optional recommended front end 4 375 ...

Страница 34: ...r NIC UTP 4 Optional recommended front end 6 7051223 2 port 10GbE optical NIC 6 Optional recommended front end 6 371 4325 02 2 port 8Gb FC HBA 4 Optional FC target or initiator backup 7 7067091 4 port 4x4 SAS 2 6Gb s external HBA 4 Additional optional back end 7 371 4325 02 2 port 8Gb FC HBA 4 Optional recommended front end 7 375 3696 01 2 port Infiniband CX2 HCA 4 Optional recommended front end 7...

Страница 35: ... specifications and diagrams 7120 7120 Hardware Overview Use the information in this section as a reference when preparing to service replaceable components of the Sun ZFS Storage 7120 Refer to the following for procedural instructions Controller Tasks replace system controller components Disk Shelf Tasks replace disk shelf components Chassis Overview The Sun ZFS Storage 7120 is an enterprise clas...

Страница 36: ...reater number of targets greater bandwidth higher reliability and bigger scale The 2U chassis form factor dimensions are as follows Dimension Measurement Dimension Measurement Height 87 6 mm 3 45 in Depth 765 25 mm 30 13 in Width 436 8 mm 17 2 in Weight 29 54 kg 65 lb Front Panel The following figure and legend show the front panel and the drive locations The Logzilla 3 5 SSD belongs in slot 3 and...

Страница 37: ...r Supply Unit 1 6 PCIe 4 11 Network Management port 2 Power Supply Unit 0 7 Boot HDD 1 12 Gbit Ethernet ports NET 0 1 2 3 3 PCIe 0 8 Boot HDD 0 13 USB 2 0 ports 0 1 4 PCIe 3 9 Rear Panel System Status LEDs 14 HD15 Video port 5 PCIe 1 10 Serial Management port The serial management connector SER MGT is an RJ 45 port and provides a terminal connection to the SP console The network management connect...

Страница 38: ...220v outlets Input Nominal frequencies 50 60Hz Nominal voltage range 100 120 200 240 VAC Maximum current AC RMS 13 8A 100 VAC AC operating range 90 264 VAC Output 3 3 VDC STBY 3 0A 12 VDC 86 7A Power dissipation Max power consumption 1235 3 W Max heat output 4212 BTU hr Volt Ampere rating 1261 VA 240 VAC 0 98P F Internal Components The chassis has the following boards installed Note Field replacea...

Страница 39: ...so supports a top cover interlock kill switch The power supplies connect directly to the power distribution board Connector Break Out Board The connector break out board is FRU and serves as the interconnect between the power distribution board and the fan power boards storage drive backplane and I O board It also contains the top cover interlock kill switch Fan Power Boards The two fan power boar...

Страница 40: ... Figure Legend 1 Top Cover 3 Hard Disk Drives 2 Right Control Panel Light Pipe Assembly 4 Left Control Panel Light Pipe Assembly Cables The following figure and legend show the storage controller internal cables 7120 Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 40 ...

Страница 41: ...ation Cable Connection 1 Storage Drive Data Cable Connection between the HBA PCI Express Card and the storage drive backplane Cable Connection 2 Ribbon cable Connection is between the power distribution board and the motherboard 7120 Chapter 1 Introduction 41 ...

Страница 42: ...e replaceable CPU and memory components of the 7120 system Part Number Description FRU CRU F371 4966 01 DIMM 8GB DDR3 2RX4 13 CRU F371 4885 01 Intel E5620 2 40G FRU All sockets must be occupied by either a filler or a DDR3 DIMM All DDR3 DIMMs must be identical DIMMs are pre installed in P0 slots D1 D2 D4 D5 D7 and D8 7120 Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 42 ...

Страница 43: ...mponents The fan modules and LEDs are shown in the following illustration The following figure and legend show the power distribution and associated components Figure Legend 1 Fan Board 5 Power Distribution Board 7120 Chapter 1 Introduction 43 ...

Страница 44: ...TB S7120 1xCPU 24GB 24TB 597 0755 01 The following table describes base configurations for the 7120 with Logzilla 3 5 SSD Mktg Part Number Description Mfg Part Number 7101282 S7120 1xCPU 24GB 3 3TB 7014523 7101284 S7120 1xCPU 24GB 6 6TB 7014525 NIC HBA Options The following table describes NIC HBA options for the 7120 Mktg Part Number Description Mfg Part Number SG XPCIESAS GEN2 Z 2 port External ...

Страница 45: ...Front end 1 PCIe 371 4325 01 QLogic 8Gb DP FC HBA Optional FC Target or Initiator Back 3 PCIe 375 3665 01 Sun Thebe INT Internal SAS HBA Base Configuration 4 PCIe 375 3481 01 Intel EXPI9404PT QP Copper NIC Optional Recommended Front end 4 PCIe 371 4325 01 QLogic 8Gb DP FC HBA Optional FC Target or Initiator Back 4 PCIe 375 3609 03 Sun Thebe EXT 8P 6Gb s SAS HBA Additional Optional Back end Attache...

Страница 46: ... used in place of up to four of the 24 drives in a disk shelf The remaining 20 drives are available for storage Refer to the http www oracle com us products servers storage storage unified storage index html http www oracle com us products servers storage storage unified storage index html for the most recent component specification The 7320 is a SAS 2 Serial Attached SCSI 2 0 device that consists...

Страница 47: ...ocator buttons and system component status LEDs The storage controller has an eight disk backplane Each drive has an LED indicator for Power Activity Fault and OK to Remove not supported The following list contains the replaceable system boards for the 7320 storage controller Part Number Description FRU CRU F541 2883 01 X8 PCIe Riser Card 1U CRU F541 2885 01 X16 PCIe Riser Card 1U CRU F541 4081 01...

Страница 48: ...age 4 Solid State Drives 5 blank USB Module 6 Right Control Panel Light Pipe Assembly 7320 CPU and Memory Components The following list contains the replaceable CPU and memory components of the 7320 Part Number Description FRU CRU F371 4966 01 DIMM 8GB DDR3 2RX4 13 CRU F371 4885 01 Intel E5620 2 40G FRU 7320 Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 48 ...

Страница 49: ...e occupied by either a filler or a DDR3 DIMM 7320 Power Distribution and Fan Module Components The following figure and legend identify the Power Distribution Fan Module components of the storage controller Figure Legend 1 Fan Modules 4 Power Distribution Bus Bar Assembly 2 Fan Board 5 Power Supplies 7320 Chapter 1 Introduction 49 ...

Страница 50: ...tors Two C13 connectors which work on 110 220v outlets Input Nominal frequencies 50 60Hz Nominal voltage range 100 120 200 240 VAC Maximum current AC RMS 9 0 amps Max AC operating range 90 264 VAC Output 3 3 VDC STBY 3 6A 12 VDC 62 3A Power dissipation Max power consumption 873 W Max heat output 2977 BTU hr Volt Ampere rating 891 VA 240 VAC 0 98P F 7320 Front Panel The following figure and legend ...

Страница 51: ... cache fill slots 2 through 5 in order Slots 6 and 7 are empty and must contain drive fillers Disk Drive Locations HDD1 HDD3 HDD5 HDD0 HDD2 HDD4 HDD6 HDD7 7320 Replaceable Components The following list contains all of the replaceable power distribution disk and fan module components of the 7320 Note that power supplies disks and fan modules are hot pluggable on the storage controller Part Number D...

Страница 52: ...XQDR PCIe CRU F375 3617 01 2X10GbE SFP X8 PCIe CRU F375 3481 01 NIC Card Quad Port 1GigE Cu PCIe CRU F511 1496 04 Sun Fishworks Cluster Controller 200 PCIe FRU 7320 Rear Panel Following is an illustration of the 7320 storage controller rear panel The Sun 375 3609 belongs in slot 2 cannot be installed in any other slots and a second is not offered as an option Figure Legend 1 Power supplies 4 Netwo...

Страница 53: ...606 03 MHJH29 XTC InfiniBand HCA Optional Recommended Front end 0 PCIe 375 3481 01 Intel EXPI9404PT QP Copper NIC Optional Recommended Front end 0 PCIe 371 4325 01 QLogic 8Gb DP FC HBA Optional FC Target or Initiator Backup 1 PCIe 375 3617 01 Intel Niantic DP Optical 10GE NIC Optional Recommended Front end 1 PCIe 375 3696 01 Mellanox InfiniBand HCA Optional Recommended Front end 1 PCIe 375 3606 03...

Страница 54: ...04PT QP Copper NIC Optional Recommended Front end 0 PCIe 371 4325 01 QLogic 8Gb DP FC HBA Optional FC Target or Initiator Backup 1 PCIe 542 0298 01 Sun Fishworks Cluster Card 2 Cluster Base Configuration 2 PCIe 375 3609 03 Sun Thebe External SAS HBA Cluster Base Configuration 7320 Connector Pinouts The serial management connector SERIAL MGT is an RJ 45 connector and is a terminal connection to the...

Страница 55: ...ller Tasks replace system controller components Disk Shelf Tasks replace disk shelf components Appliance Overview The Sun ZFS Storage 7420 Appliance consists of a standalone storage controller or two storage controllers in a high availability cluster configuration and one to 36 disk shelves The following table describes the 7420 configuration options Note 7420 M2 controllers cannot be clustered wi...

Страница 56: ...surement Dimension Measurement Height 13 3 cm 5 25 in Depth 70 6 cm 27 8 in Width 43 7 cm 17 19 in Weight 16 36 kg 96 lbs Front Panel Figure Legend 1 Locator LED and button white 7 Power Supply PS Service Required LED 13 SSD 2 optional 2 Service Required LED amber 8 Over Temperature Warning LED 14 SSD 3 optional 3 Power OK LED green 9 USB 2 0 Connectors 15 SSD 4 optional 4 Power button 10 DB 15 vi...

Страница 57: ...llers have two 500GB SATA system boot drives in slots 0 and 1 configured as a mirrored pair Zero two three or four 512GB SSDs may optionally fill slots 2 through 5 in order In a 7420 cluster the number of SSDs installed in both controllers must match Figure Legend 1 Locate white 2 Service action required amber 3 OK Activity green Rear Panel The following graphic shows the rear panel of the control...

Страница 58: ...t 11 Network management NET MGT port 5 System status LEDs Power green Attention amber Locate white 12 Serial management SER MGT port 6 PCIe slots 0 4 13 DB 15 video connector 7 Cluster card slot Connectors The serial management connector SER MGT is an RJ 45 connector and provides a terminal connection to the SP console The network management connector NET MGT is an RJ 45 connector and provides a L...

Страница 59: ...modules slots for eight DIMM risers memory control subsystems and the service processor SP subsystem The SP subsystem controls the host power and monitors host system events power and environmental The SP controller draws power from the host s 3 3V standby supply rail which is available whenever the system is receiving AC input power even when the system is turned off Power Distribution Board The ...

Страница 60: ...em component status LEDs Each drive has an LED indicator for Power Activity Fault and Locate Components The controller components are shown in the following figure and identified in the table Figure Legend 1 Motherboard 7 CPUs and heatsinks 2 Low profile PCIe cards 8 Memory risers 3 Power supplies 9 Fan board 4 Power supply backplane 10 Fan modules 5 Drive backplane 11 Boot drives and SSDs 6 Syste...

Страница 61: ...ed CPU sockets must have fillers installed Previous 7420 controller configurations support two or four 1 86GHz or 2 00GHz CPUs with two memory risers required by each CPU Four or eight 4GB or 8GB DDR3 DIMMs are installed on each riser accommodating up to 256GB of memory for two CPUs or up to 512GB for four CPUs Refer to the service label on the cover for DIMM placement information On every memory ...

Страница 62: ... figure The following LEDs are lit when a fan module fault is detected Front and rear Service Action Required LEDs Fan Module Service Action Required TOP LED on the front of the server Fan Fault LED on or adjacent to the faulty fan module The system Overtemp LED might light if a fan fault causes an increase in system operating temperature 7420 Oracle ZFS Storage Appliance Installation Guide Januar...

Страница 63: ...ptional PCIe card slots for standalone and cluster configurations Note The 7420 M2 reserves slot 0 for a SAS 2 internal HBA and slots 1 and 8 for two SAS 2 external HBAs Slot Mfg Part Number Description Max Note 0 7054001 8 port 6Gb s SAS 2 internal HBA 1 Slot 0 of the 7420 M2 is reserved for the SAS 2 internal HBA 0 371 4325 02 8Gb 2 port FC HBA 6 Optional FC target or initiator Backup for the 74...

Страница 64: ...ed front end 4 7051223 2 port optical 10GE NIC 6 Optional recommended front end 4 371 4325 02 8Gb 2 port FC HBA 6 Optional FC target or initiator Backup 4 375 3696 01 CX2 Infiniband HCA 4 Optional recommended front end C 7056175 Cluster Controller 200 1 Cluster base configuration 5 7054739 4 port copper NIC 6 Optional recommended front end 5 375 3606 03 CX1 Infiniband HCA 4 Optional recommended fr...

Страница 65: ...1 CX2 Infiniband HCA 4 Optional recommended front end 8 F375 3609 03 7059331 for EU countries 2 port SAS external HBA 6 Base configuration 2 minimum 9 371 4325 02 8Gb 2 port FC HBA 6 Optional FC target or initiator Backup 9 7051223 2 port optical 10GbE NIC 6 Optional recommended front end 9 7054739 4 port copper NIC 6 Optional recommended front end PCIe Slot Order When installing additional PCIe c...

Страница 66: ...component specifications and diagrams Shelf Disk Shelf Overview Oracle disk shelves are high availability serial attached SCSI SAS devices that provide expanded storage The main components are hot swappable including drives I O Modules IOMs or SAS Interface Module SIM boards for connecting to controllers and other disk shelves and dual load sharing power supply with fan modules This provides a fau...

Страница 67: ... Modules IOMs and dual power supply with fan modules Oracle Storage Drive Enclosure DE2 24C The Oracle Storage Drive Enclosure DE2 24C is a 4U chassis that supports 24 3 5 SAS 2 drives The SSDs provide accelerated write operations and the high capacity HDDs provide reliable storage This disk shelf features dual redundant I O Modules IOMs and dual power supply with fan modules Sun Disk Shelf 24x3 5...

Страница 68: ...ition the high performance SAS 2 HBA is designed for the Sun ZFS Storage 7000 series with a standard chip set to support a high density of target devices capable of attachment to 1024 targets With this fabric you are encouraged to apply entire shelves to pools so you can gain the benefits of No Single Point of Failure configurations and striping across the maximum possible number of devices The fo...

Страница 69: ...d Sun Disk Shelf Up to four Logzilla SSDs are supported per disk shelf Logzilla SSDs should be populated in order of slots 20 21 22 and 23 The Oracle Storage Drive Enclosure DE2 24C is shown and represents both models Front Panel Indicators The following figures show the front panel indicators Oracle Storage Drive Enclosure DE2 24P Shelf Chapter 1 Introduction 69 ...

Страница 70: ...wer indicator 4 Drive fault indicator 2 Module fault indicator 5 Power Activity indicator 3 Locate indicator Oracle Storage Drive Enclosure DE2 24C Shelf Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 70 ...

Страница 71: ...f Figure Legend 1 Locate button and indicator 4 Disk ready to be removed indicator 7 Over temperature warning indicator 2 System fault indicator 5 Disk fault indicator 8 SIM board fault indicator 3 System power indicator 6 Disk activity indicator 9 Power supply fault indicator Oracle Storage Drive Enclosure DE2 24P Shelf Chapter 1 Introduction 71 ...

Страница 72: ...e Enclosure DE2 24C Figure Legend 1 Power Supply Filler Panel Slot 0 4 Power Supply Filler Panel Slot 3 7 I O Module Filler Panel 2 Power Supply with Fan Module 1 5 I O Module Filler Panel 8 I O Module 1 3 Power Supply with Fan Module 2 6 I O Module 0 Shelf Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 72 ...

Страница 73: ...with built in fans Power supply 0 is on the left and power supply 1 is on the right 2 Removable SAS Interface Module SIM Boards SIM 0 is on the left and SIM 1 is on the right I O Module Indicators The following disk shelves have I O Modules IOMs Oracle Storage Drive Enclosure DE2 24P Oracle Storage Drive Enclosure DE2 24C Shelf Chapter 1 Introduction 73 ...

Страница 74: ...ort 2 8 For Oracle service only 3 SAS 2 Port 0 6 Host port activity indicators SIM Board Indicators The following disk shelves have SIM boards Sun Disk Shelf The following figure shows the SIM board indicators for the Sun Disk Shelf Shelf Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 74 ...

Страница 75: ...ault indicator 9 SIM board OK indicator green SIM board fault indicator amber 5 Universal power connector 10 SIM locator indicator Power Supply Indicators The following figure shows power supply with fan module indicators for these disk shelves Oracle Storage Drive Enclosure DE2 24P Oracle Storage Drive Enclosure DE2 24C Shelf Chapter 1 Introduction 75 ...

Страница 76: ...ator 7 Power cord tie wrap 3 AC power fail indicator 4 Power supply status indicator 5 Power on off switch The following figure shows power supply with fan module indicators for these disk shelves Sun Disk Shelf Shelf Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 76 ...

Страница 77: ...ht ejection arm and captive screw latch 4 Power supply status indicator 5 Power on off switch Disk Shelf Configurations The following tables describe and provide part numbers for the supported expansion storage shelves Oracle Storage Drive Enclosure DE2 24P Mktg Part Number Description 7103910 Drive Enclosure DE2 24P Base Chassis Shelf Chapter 1 Introduction 77 ...

Страница 78: ...S 2 3 5 HDD 7103916 73GB SSD XATO SAS 2 2 5 2 5 to 3 5 Drive Adapter 7103918 Filler Panel Drive Enclosure DE2 24C Sun Disk Shelf DS2 Mktg Part Number Description DS2 0BASE Sun Disk Shelf DS2 24x3 5 SAS 2 DS2 HD2T 2TB 7 2Krpm SAS 2 3 5 HDD 7101765 3TB 7 2Krpm SAS 2 3 5 HDD 7101274 300GB 15Krpm SAS 2 3 5 HDD 7101276 600GB 15Krpm SAS 2 3 5 HDD 7101197 73GB SSD XATO 3 5 DS2 LOGFILLER Sun Disk Shelf DS...

Страница 79: ... controllers in a high availability cluster and expand storage The following topics are described Overview Controllers ZS3 2 ZS3 4 7x20 family Attached Storage Oracle Storage Disk Shelf DE2 24C Oracle Storage Disk Shelf DE2 24P Sun Disk Shelf Connecting to Attached Storage Powering on Initial configuration 2 C H A P T E R 2 79 ...

Страница 80: ...pecifications ZS3 4 Overview view component diagrams and specifications 7120 Overview view component diagrams and specifications 7320 Overview view component diagrams and specifications and cluster options 7420 Overview view component diagrams specifications and cluster options For controller installation check that your rack is compatible with the slide rail and cable management assembly options ...

Страница 81: ...t shipped with installation instructions use those instructions instead Observe the following cautions Always load equipment into a rack from the bottom up so that it will not become top heavy and tip over Deploy the anti tip bar to the prevent the rack from tipping during equipment installation Ensure that the temperature in the rack will not exceed the controller s maximum ambient rated temperat...

Страница 82: ...onnected to a terminal server Tasks ZS3 2 ControllersTasks Installing the Mounting Brackets and Slide Rail Assemblies If the mounting brackets are shipped inside the slide rails you must remove them before beginning this procedure as follows Unpack the slide rails and locate the slide rail lock at the front of the assembly Squeeze and hold the tabs at top and bottom of the lock 1 while you pull th...

Страница 83: ... bracket release button toward the front of the mounting bracket 2 while withdrawing the bracket from the assembly Attach a mounting bracket to each side of the controller 3 4 ZS3 2 Controllers Chapter 2 Installation 83 ...

Страница 84: ... will be installing the rail plate as shown Position a slide rail assembly in your rack so that the brackets at each end of the slide rail assembly are on the outside of the front and back rack posts The following graphic illustrates 5 6 ZS3 2 Controllers Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 84 ...

Страница 85: ...the rail assembly brackets Attach each slide rail assembly to the rack posts but do not tighten the screws completely 7 ZS3 2 Controllers Chapter 2 Installation 85 ...

Страница 86: ...ntation for detailed instructions Installing the Controller into the Rack Caution This procedure requires a minimum of two people because of the weight of the chassis Attempting this procedure alone could result in equipment damage or personal injury Always load equipment into rack from the bottom up Pull the slide rails mounted in the slide rail assembly toward you until the slide rails stop appr...

Страница 87: ...ks usage Installing the Cable Management Arm Unpack the CMA and identify its components See CMA components If the CMA has flat cable covers for a 1U chassis install the 2U round cable covers provided in the accessory kit To replace the flat cable covers Remove each flat cable cover by lifting up on the cable cover handle 1 and open it 180 degrees to the horizontal position 2 Apply upward pressure ...

Страница 88: ...vent the rack from tipping ensure all anti tilt devices on the rack are extended Extend the storage controller approximately 13 cm 5 inches out of the front of the rack At the back of the rack insert the CMA s connector A into the front slot on the left slide rail until it locks into place with an audible click frames 1 and 2 The connector A tab 1 goes into the slide rail s front slot 2 Gently tug...

Страница 89: ...the front slide bar to verify that connector B is properly seated To install the CMA s connector C into the right slide rail perform the following steps Align connector C with the slide rail so that the locking spring 1 is positioned inside server side of the right slide rail frame 1 Insert connector C into the right side rail until it locks into place with an audible click frames 2 and 3 Gently t...

Страница 90: ...r D locks into place with an audible click frames 1 and 2 When inserting connector D into the slide rail the preferred and easier method is to install connector D and the latching bracket as one assembly into the slide rail Gently tug on the left side of the CMA s rear slide bar to verify that connector D is properly seated Gently tug on the four CMA connection points to ensure that the CMA connec...

Страница 91: ...e cable troughs in this order a Route the cables through the front most cable trough b then through the small cable trough c then through the rear most cable trough When securing the cables with theVelcro straps located on the front slide bar ensure that the Velcro straps do not wrap around the bottom of the slide bar otherwise expansion and contraction of the slide bar might be hindered when the ...

Страница 92: ... CMA as required Removing the CMA Ensure all rack anti tilt devices are extended to prevent the rack from tipping forward when the storage controller is extended from the rack To make it easier to remove the CMA extend the storage controller approximately 13 cm 5 inches out of the front of the rack To remove the cables from the CMA do the following Disconnect all cables from the rear of the storag...

Страница 93: ...tor A perform the following steps Place your left arm under the CMA to support it and grasp the rear end of connector A with your left hand Use your right thumb to pull the connector A release lever to the right away from the left slide rail and use your left hand to pull the connector out of the slide rail Remove the CMA from the rack and place it on a flat surface Go to the front of the rack and...

Страница 94: ...ns You also need a system console device such as one of the following Sun workstation ASCII terminal Terminal server Patch panel connected to a terminal server Tasks ZS3 4 ControllersTasks Installing Mounting Brackets on the Controller Chassis If the mounting brackets are shipped inside the slide rails you must remove them before beginning this procedure as follows Unpack the slide rails and locat...

Страница 95: ... rail lock is at the front of the chassis and the keyed openings on the mounting bracket are aligned with the locating pins on the side of the chassis The following graphic illustrates how to attach the mounting brackets 1 ZS3 4 Controllers Chapter 2 Installation 95 ...

Страница 96: ... requires a minimum of two people because of the weight of the chassis Attempting this procedure alone could result in equipment damage or personal injury Always load equipment into rack from the bottom up If you are using a universal 19 inch cabinet snap an M6 square cage nut into the top and bottom holes of the location where you will be installing the rail plate as shown Position a slide rail a...

Страница 97: ...the rail assembly brackets Attach each slide rail assembly to the rack posts but do not tighten the screws completely 3 ZS3 4 Controllers Chapter 2 Installation 97 ...

Страница 98: ...f the rails with the rail width spacer 1 Tighten the screws on the brackets Remove the spacer and confirm that the rails are attached tightly to the rack 4 5 6 ZS3 4 Controllers Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 98 ...

Страница 99: ...t extend it from the bottom of the rack Lower the rack stabilization feet if you have not already done so Push the slide rails into the slide rail assemblies in the rack as far as possible 7 8 9 ZS3 4 Controllers Chapter 2 Installation 99 ...

Страница 100: ...s slowly until the mounting brackets meet the slide rail stops 12 in or 30 cm You will hear an audible click The following graphic illustrates chassis insertion Installing the Cable Management Assembly This procedure is completed from the back of the equipment rack 10 ZS3 4 Controllers Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 100 ...

Страница 101: ...ly CMA rail extension to the left slide rail until the extension locks into place Insert the CMA mounting bracket connector into the right slide rail until the connector locks into place 1 2 ZS3 4 Controllers Chapter 2 Installation 101 ...

Страница 102: ...t the right CMA slide rail connector 1 into the right slide rail assembly 2 until the connector locks into place 3 ZS3 4 Controllers Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 102 ...

Страница 103: ...Insert the left CMA slide rail connector 1 into the rail extension on the left slide rail assembly 2 until the connector locks into place 4 ZS3 4 Controllers Chapter 2 Installation 103 ...

Страница 104: ... installation instructions use those instructions instead Observe the following cautions Always load equipment into a rack from the bottom up so that it will not become top heavy and tip over Deploy the anti tip bar to the prevent the rack from tipping during equipment installation Ensure that the temperature in the rack will not exceed the controller s maximum ambient rated temperatures Consider ...

Страница 105: ...e following Sun workstation ASCII terminal Terminal server Patch panel connected to a terminal server Tasks 7x20 ControllersTasks Installing Mounting Brackets on the Controller Chassis If the mounting brackets are shipped inside the slide rails you must remove them before beginning this procedure as follows Unpack the slide rails and locate the slide rail lock at the front of the assembly Squeeze ...

Страница 106: ...The following graphic illustrates the procedure for disassembling the 7420 rail kit 7x20 Controllers Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 106 ...

Страница 107: ... lock is at the front of the chassis and the keyed openings on the mounting bracket are aligned with the locating pins on the side of the chassis The following graphic illustrates how to attach the 7120 7320 mounting brackets 1 7x20 Controllers Chapter 2 Installation 107 ...

Страница 108: ...ify that all mounting pins are securely fastened to the chassis Repeat to install the remaining mounting bracket on the other side of the chassis Installing the Controller Chassis into the Rack Slide Rails This procedure requires a minimum of two people because of the weight of the chassis Attempting this procedure alone could result in equipment damage or personal injury Always load equipment int...

Страница 109: ...f the location where you will be installing the rail plate as shown Position a slide rail assembly in your rack so that the brackets at each end of the slide rail assembly are on the outside of the front and back rack posts The following graphic illustrates 1 2 7x20 Controllers Chapter 2 Installation 109 ...

Страница 110: ...ail assembly brackets Attach each slide rail assembly to the rack posts but do not tighten the screws completely 3 7x20 Controllers Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 110 ...

Страница 111: ...k set the proper width of the rails with the rail width spacer 1 Tighten the screws on the brackets Remove the spacer and confirm that the rails are attached tightly to the rack 4 5 6 7x20 Controllers Chapter 2 Installation 111 ...

Страница 112: ...tom of the rack Lower the rack stabilization feet if you have not already done so Push the slide rails into the slide rail assemblies in the rack as far as possible 7 8 9 7x20 Controllers Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 112 ...

Страница 113: ...sert the chassis into the slide rails pushing the chassis slowly until the mounting brackets meet the slide rail stops 12 in or 30 cm You will hear an audible click The following graphic illustrates the 7120 7320 chassis insertion and slide rail locks usage 10 7x20 Controllers Chapter 2 Installation 113 ...

Страница 114: ...strates 7420 chassis insertion Installing the Cable Management Assembly This procedure is completed from the back of the equipment rack 7x20 Controllers Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 114 ...

Страница 115: ...bly CMA rail extension to the left slide rail until the extension locks into place Insert the CMA mounting bracket connector into the right slide rail until the connector locks into place 1 2 7x20 Controllers Chapter 2 Installation 115 ...

Страница 116: ...t the right CMA slide rail connector 1 into the right slide rail assembly 2 until the connector locks into place 3 7x20 Controllers Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 116 ...

Страница 117: ...Insert the left CMA slide rail connector 1 into the rail extension on the left slide rail assembly 2 until the connector locks into place 4 7x20 Controllers Chapter 2 Installation 117 ...

Страница 118: ...nto a rack from the bottom up so that it will not become top heavy and tip over Deploy the anti tip bar to prevent the rack from tipping during equipment installation Ensure that the temperature in the rack does not exceed the controller s maximum ambient rated temperatures Consider the total airflow requirements of all equipment installed in the rack to ensure that the equipment is operated withi...

Страница 119: ...ing racks for the disk shelf Sun Rack II 1042 1242 cabinet Any 19 inch wide 4 post EIA compatible rack or cabinet with a front to back depth between vertical cabinet rails of 61 cm to 91 cm 24 in to 36 in The cabinet can have threaded or unthreaded cabinet rails Threaded cabinets must be M6 or 10 32 cabinets Cabinets must be able to support the weight of all equipment contained within them Positio...

Страница 120: ...round hole cabinets and place aside Threaded cabinet Remove screws and replace them in the opposite direction from the inside of the rail flange so they act as location pins Also remove the clip nut from each front rail end and discard Position the front of the rails inside the cabinet with the rail flange inside of the cabinet flange and the rail label facing the inside of the cabinet Square hole...

Страница 121: ...nt of each rail Do not install into the cage nut in the rack or the clip nut on the rail Threaded cabinet The location pins fit inside the rack holes Adjust the rail lengths to fit Install one screw through the rack and into the rear of each rail 5 6 DE2 24C Chapter 2 Installation 121 ...

Страница 122: ...Tighten the two locking screws in the rails 7 DE2 24C Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 122 ...

Страница 123: ...d right rails Do not lift using the power supply handles Carefully slide the shelf into the cabinet Ensure that the shelf is fully seated within the rails If removing the shelf to reseat it support it at all times Remove the front side caps install two screws into each front side and replace the caps 8 9 10 DE2 24C Chapter 2 Installation 123 ...

Страница 124: ...upply input voltage range of 100 240 VAC 50 60 Hz The disk shelves are compatible with 100 120 VAC or 200 240 VAC sources The power source must not be overloaded by the total number of disk shelves in the cabinet At full load each DE2 24 draws 1 140W and each Sun Disk Shelf draws 912W The power source must provide a reliable earth connection for each disk shelf and the cabinet Ensure that the powe...

Страница 125: ...shelf is lit a steady green and that each power supply with fan module status indicator on the rear is lit a steady green If not power off the disk shelf as described in the next section and reseat the faulted module If the module status indicator is not a steady green after module reinsertion contact Oracle Customer Service Perform the software setup tasks as described in the storage controller i...

Страница 126: ...Oracle Storage Drive Enclosure DE2 24P into a rack using the supplied rail kit Note that if your rail kit shipped with installation instructions use those instructions instead Always load equipment into a rack from the bottom up so that it will not become top heavy and tip over Deploy the anti tip bar to prevent the rack from tipping during equipment installation Ensure that the temperature in the...

Страница 127: ...unthreaded cabinet rails Threaded cabinets must be M6 or 10 32 cabinets Cabinets must be able to support the weight of all equipment contained within them Position the rack where the shelf is to be installed adjacent to the rack where the controller is installed if separate Stabilize the cabinet and lock the casters To facilitate access remove doors from cabinets Tasks DE2 24PTasks Installing the ...

Страница 128: ...the rails b Use the supplied wrench to insert two pins into each end of the rails in the same location where the location pegs were removed c Position the front of the rails inside the cabinet with the rail flange inside of the cabinet flange and the rail label facing the inside of the cabinet The pins should be fully located within the rack holes d Insert and tighten one screw through the front o...

Страница 129: ...o the back of the rails Using a mechanical lift or two people one at each side of the disk shelf carefully lift and rest the shelf on the bottom ledge of the left and right rails Do not lift using the power supply with fan module handles 4 DE2 24P Chapter 2 Installation 129 ...

Страница 130: ...f the shelf to the rear of the rack If the screw cannot be inserted the shelf might not be fully seated within the rails Remove the front side caps install one screw into each front side and replace the caps Connect and apply power to the disk shelf as described in the next section Powering On the Disk Shelf Ensure you have met the following electrical safety measures before applying power to the ...

Страница 131: ...or the cabinet Note To guarantee redundancy power cords must be connected to two separate and independent power sources Apply power to the external power source Place the power supply on off switches to the I on position Turn on the cabinet circuit breakers if applicable After the disk shelf powers on which could take several minutes ensure that the system power indicator on the front of the disk ...

Страница 132: ...on off switches to the O off position Disconnect the power cords from the external power source for the cabinet All power cords must be disconnected to completely remove power from the disk shelf See Also Cabling Diagrams Sun Disk Shelf Precautions Observe the following cautions when installing a Sun Disk Shelf into a rack using the rail assembly in the bolt on rack mount kit Note that if your rac...

Страница 133: ...for instructions Use one of the following racks for the Sun Disk Shelf Sun Rack 900 1000 cabinet Sun Fire cabinet Sun StorEdge Expansion cabinet Sun Rack II 1042 1242 cabinet Any 19 inch wide 4 post EIA compatible rack or cabinet with a front to back depth between vertical cabinet rails of 61 cm to 91 cm 24 in to 36 in The cabinet can have threaded or unthreaded cabinet rails Position the rack whe...

Страница 134: ...u will be installing the system Install in the top and bottom holes Install appropriate rail plates in four locations on the rack 2 front and 2 back by aligning the two pins on the rail plate with holes on the cabinet rails 2 3 Sun Disk Shelf Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 134 ...

Страница 135: ...l each rail by first aligning the front pins of the rack adapter plates with corresponding holes in the front of the rail then adjust the rail to fit the rack and insert the pins from the rear rack adapter plates into the corresponding holes of the rail 4 5 Sun Disk Shelf Chapter 2 Installation 135 ...

Страница 136: ...Install four 8 32 screws into the four remaining front and rear holes of each rack rail 16 total 6 Sun Disk Shelf Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 136 ...

Страница 137: ...chassis insertion Carefully slide the shelf into the cabinet until the front flanges of the shelf touch the vertical face of the rack Tighten the captive screws on each side of the front of the shelf to secure the shelf to the rack At the back of the disk shelf slide a system locking clip onto each lower corner of the chassis See Also Cabling Diagrams 7 8 9 10 Sun Disk Shelf Chapter 2 Installation...

Страница 138: ...138 ...

Страница 139: ...es to an individual chain Balance the number of disk shelves across the disk chains in your system Disks with different capacities or rotation speeds cannot be mixed within a single disk shelf To use mixed disk shelf types the controller must have only 4X4 port SAS 2 HBAs Do not use mixed disk shelves in the same chain each must be on their own SAS fabric The following list provides links to cable...

Страница 140: ... ZS3 2 Maintenance Procedures PCIe Cards ZS3 4 Maintenance Procedures PCIe Cards and Risers 7x20 Maintenance Procedures PCIe Cards and Risers Summary of Controller Configurations Maximum Controller Configurations The following table shows the maximum supported controller configurations NOTE Controllers cannot use 2X4 port SAS 2 HBAs and 4X4 port SAS 2 HBAs at the same time To use DE2 and Sun Disk ...

Страница 141: ...dalone controllers with one or two HBAs Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model Cable Diagrams fig 1 Standalone controller with one HBA and one disk shelf in a single chain fig 2 One HBA and two disk shelves in two chains fig 3 Two HBAs and two disk shelves in two chains DE2 to ZS3 2 7120 7320 Standalone Chapter 3...

Страница 142: ...ves The following figures show a subset of the supported configurations for Oracle ZFS Storage ZS3 2 7320 clustered controllers with one HBA Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model Cable Diagrams DE2 to ZS3 2 7320 Clustered Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 142 ...

Страница 143: ...e HBA and one disk shelf in a single chain fig 2 One HBA and two disk shelves in two chains fig 3 One HBA and multiple disk shelves in two chains fig 4 Four disk shelves in a single chain DE2 to ZS3 2 7320 Clustered Chapter 3 Cabling 143 ...

Страница 144: ...lone controllers with three HBAs Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model Cable Diagrams fig 1 Standalone controller with three HBAs and one disk shelf in a single chain fig 2 Three HBAs and two disk shelves in two chains DE2 to ZS3 4 7420 Standalone Oracle ZFS Storage Appliance Installation Guide January 2014 E484...

Страница 145: ...hree HBAs and three disk shelves in three chains fig 4 Three HBAs and six disk shelves in six chains fig 5 Three HBAs with multiple disk shelves in six chains DE2 to ZS3 4 7420 Standalone Chapter 3 Cabling 145 ...

Страница 146: ...age ZS3 4 7420 clustered controllers with three HBAs Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model Cable Diagrams fig 1 Clustered controllers with three HBAs and one disk shelf in a single chain fig 2 Three HBAs and two disk shelves in two chains DE2 to ZS3 4 7420 Clustered Oracle ZFS Storage Appliance Installation Guid...

Страница 147: ...Three HBAs and three disk shelves in three chains fig 4 Three HBAs and six disk shelves in six chains fig 5 Three HBAs and multiple disk shelves in six chains DE2 to ZS3 4 7420 Clustered Chapter 3 Cabling 147 ...

Страница 148: ...age 7120 7320 standalone controllers with one HBA Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model Cable Diagrams fig 1 Standalone controller with one HBA and one disk shelf in a single chain fig 2 One HBA and two disk shelves in a single chain 7120 7320 Cabling Oracle ZFS Storage Appliance Installation Guide January 2014 ...

Страница 149: ...a subset of the supported configurations for Oracle ZFS Storage 7320 clustered controllers with one HBA Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model Cable Diagrams fig 1 Clustered controllers with one HBA and one disk shelf in a single chain 7320 Cluster Cabling Chapter 3 Cabling 149 ...

Страница 150: ... 2 and 6 HBAs The following figures show a subset of the supported configurations for Oracle ZFS Storage 7420 standalone controllers with two and six HBAs Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model Cable Diagrams 7420 Cabling Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 150 ...

Страница 151: ... one disk shelf in a single chain fig 2 Two HBAs and two disk shelves in two chains fig 3 Two HBAs and 12 disk shelves in two chains fig 4 Standalone controller with six HBAs and one disk shelf in a single chain 7420 Cabling Chapter 3 Cabling 151 ...

Страница 152: ...hains fig 6 Six HBAs and three disk shelves in three chains fig 7 Six HBAs and six disk shelves in six chains fig 8 Six HBAs and 36 disk shelves in six chains 7420 Cabling Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 152 ...

Страница 153: ...ZFS Storage 7420 clustered controllers with two and six HBAs Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model Cable Diagrams fig 1 Clustered controllers with two HBAs and one disk shelf in a single chain fig 2 Two HBAs and two disk shelves in two chains 7420 Cluster Cabling Chapter 3 Cabling 153 ...

Страница 154: ...n two chains fig 4 Clustered controllers with six HBAs and one disk shelf in a single chain fig 5 Six HBAs and two disk shelves in two chains 7420 Cluster Cabling Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 154 ...

Страница 155: ...fig 6 Six HBAs and three disk shelves in three chains fig 7 Six HBAs and six disk shelves in six chains fig 8 Six HBAs and 36 disk shelves in six chains 7420 Cluster Cabling Chapter 3 Cabling 155 ...

Страница 156: ...4X4 port SAS 2 HBAs Do not use mixed disk shelves in the same chain Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model 4X4 port SAS 2 HBAs are only supported with release AK 2013 1 0 and later Cable Diagrams fig 1 Standalone controller with one HBA and two disk shelves in two chains DE2 24 on the left fig 2 Eight disk shelve...

Страница 157: ...er must use only 4X4 port SAS 2 HBAs Do not use mixed disk shelves in the same chain Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model 4X4 port SAS 2 HBAs are only supported with release AK 2013 1 0 and later Cable Diagrams fig 1 Clustered controllers with one HBA and two disk shelves in two chains DE2 24 on the left fig 2 ...

Страница 158: ...ires the following The controller must use only 4X4 port SAS 2 HBAs Do not use mixed disk shelves in the same chain Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model 4X4 port SAS 2 HBAs are only supported with release AK 2013 1 0 and later Cable Diagrams fig 1 Clustered controllers with two HBAs and multiple mixed disk shel...

Страница 159: ...ustered controllers with two HBAs Using mixed disk shelves on a controller requires the following The controller must use only 4X4 port SAS 2 HBAs Do not use mixed disk shelves in the same chain Note For hardware port locations see the PCIe Options section in the Hardware Maintenance Overview for your controller model 4X4 port SAS 2 HBAs are only supported with release AK 2013 1 0 and later Cable ...

Страница 160: ...d multiple mixed disk shelves in two chains DE2 24 on the left fig 2 Eight disk shelves in two chains DE2 24 on the left ZS3 4 7420 Clustered with DE2 and Sun Disk Shelves Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 160 ...

Страница 161: ...tallation section for detailed instructions to install your system in the rack Complete the system cabling according to the Cabling Diagrams section Gather the following information in preparation for configuring an Ethernet interface on the storage controller IP address IP netmask Host name Domain Name Server DNS domain name DNS server IP address Default router IP address Password If you will acc...

Страница 162: ...tform data collection WARNING Failure to configure ILOM connectivity may lead to longer than necessary hardware fault diagnosis and resolution times Tasks The following procedures describe how to power on the appliance PowerTasks Powering On the Appliance You can access the system by connecting an administrative client to the serial management port on the controller Alternatively if there is a Dyn...

Страница 163: ...and issue the appropriate command as follows For a serial port concentrator connect for example using telnet and use root as the user name and replace serial concentrator portnumber with the appropriate value for example telnet serial concentrator portnumber For a network connection connect using SSH and use root as the user name and determine the IP address by accessing your DHCP server for the a...

Страница 164: ... the NET0 port as follows https ipaddress 215 or https hostname 215 The login screen appears Type root into the Username field and the administrative password that you entered into the appliance shell kit interface and press the Enter key TheWelcome screen appears To begin configuring the system click Start on theWelcome screen You are guided through the Initial Configuration of the remaining netw...

Страница 165: ...areful attention to the Clustering Considerations for Networking section Alternatively cluster capable appliances may be initially configured for standalone operation using the following procedure and re configured for cluster operation at a later time Summary This procedure will configure networking connectivity several client network services and the layout of the storage pool for standalone ope...

Страница 166: ... least one NIC port configured as a management interface Select the Allow Admin option in the BUI to enable BUI connections on port 215 and CLI connections on ssh port 22 All cluster installations should have at least one NIC port on each controller configured as a management interface as described above In addition the NIC instance number must be unique on each controller CLI Alternatively use th...

Страница 167: ...u will configure clustering aksh starting configuration with net Configure Networking Configure the appliance network interfaces The first network interface has been configured for you using the settings you provided at the serial console Subcommands that are valid in this context datalinks Manage datalinks devices Manage devices interfaces Manage interfaces help topic Get context sensitive help I...

Страница 168: ...erating on dns get prop Get value for property prop help properties for valid properties If prop is not specified returns values for all properties set prop Set property prop to value help properties for valid properties For properties taking list values value should be a comma separated list of values caji maintenance system setup dns show Properties status online domain sun com servers 192 168 1...

Страница 169: ...mma separated list of values caji maintenance system setup ntp set servers 0 pool ntp org servers 0 pool ntp org uncommitted caji maintenance system setup ntp commit caji maintenance system setup ntp done aksh done with ntp advancing configuration to directory Refer to the NIS LDAP and Active Directory sections for additional documentation Configure Name Services Configure directory services for u...

Страница 170: ... Configure Storage Subcommands that are valid in this context help topic Get context sensitive help If topic is specified it must be one of builtins commands general help script or properties show Show information pertinent to the current context commit Commit current state including any changes done Finish operating on storage config pool Configure the storage pool unconfig Unconfigure the storag...

Страница 171: ...tallation Controller Update Maintaining controller software in advance of putting your appliance into production enables you to reap the greatest benefits of recent software enhancements In many cases a simple software update will resolve an issue observed in testing or provide you with new enhancements that improve productivity Update storage controllers to the latest software and associated firm...

Страница 172: ...ip the downloaded file using an archive manager or by issuing the unzip command The file is expanded into the All_Supported_Platforms directory 9 To upload and apply the update use the Updating via the BUI or Updating via the CLI procedures in the Maintenance System online help page Update Oracle ZFS Storage Appliance Installation Guide January 2014 E48491 02 172 ...

Страница 173: ...torage Controller See Storage Controller CPU Central Prcessing Unit CRU Customer Replaceable Component Dashboard appliance summary display of system health and activity Dataset the in memory and on disk data for a statistic from Analytics DIMM dual in line memory module Disk Shelf the expansion storage shelf that is connected to the head node or storage controller DNS Domain Name Service DTrace a ...

Страница 174: ... LED light emitting diode Logzilla write IOPS accelerator LUN Logical Unit Masthead top section of BUI screen Modal Dialog a new screen element for a specific function NFS Network File System NIC Network Interface Card NIS Network Information Service PCIe Peripheral Component Interconnect Express PCM Power Cooling Module consisting of a PSU and one or more fans Pool provide storage space that is s...

Страница 175: ...re Share ZFS filesystem shared using data protocols SIM SAS Interface Module Snapshot an image of a share SSD Solid State Drive SSH Secure Shell Statistic a metric visible from Analytics Storage Controller the head node of the appliance Support Bundle auto generated files containing system configuration information and core files for use by remote support in debugging system failures Title Bar loc...

Страница 176: ...176 ...

Отзывы: