10.
7120 or 7320:
Components may differ slightly between the 7120 and 7320, however service
procedures for each are identical. The illustration shows the 7320. To install the top cover:
Place the top cover on the chassis so that it hangs over the rear of the storage controller by
about an inch (2.5 cm), then slide the top cover forward until it seats.
Close the fan cover and engage the fan cover latches. The cover must be completely closed
for the storage controller to power on.
11.
7420:
To install the top cover:
Place the top cover on the chassis (1) so that it is forward of the rear of the storage controller
by about an inch (2.5 cm).
Slide the top cover toward the rear of the chassis (2) until it seats.
Press down on the cover with both hands until both latches engage.
12. Push the release tabs on the side of each rail and slowly push the storage controller into the
rack, making sure no cables obstruct the path of the controller.
7x20
Chapter 2 • Hardware Maintenance
71