42
Sun Network QDR InfiniBand Gateway Switch Service Manual for Firmware Version 2.1 • March 2013
1. Check to see if any System Service Required LEDs are lit or flashing.
See
“Check Chassis Status LEDs” on page 4
.
2. Visually inspect the power supplies to see if any of their status LEDs are lit or
flashing.
See
“Check Power Supply Status LEDs” on page 6
.
If a power supply is faulty, replace it. See
“Remove a Power Supply” on page 47
.
3. Access the Oracle ILOM CLI.
See
“Access the Oracle ILOM CLI (NET MGT Port)” on page 35
.
4. Verify that a power supply is faulty.
If a power supply is faulty, you will see
/SYS/PSU
x
listed in the output under
Target:
, where
x
is
0
(left power supply) or
1
(right power supply).
For example:
If a power supply is faulty, replace it. See
“Remove a Power Supply” on page 47
.
If a FRU value in addition to or different from
/SYS/PSU
x
is displayed, see
“Clearable Fault Targets” on page 11
to identify which component is faulty.
In no Oracle ILOM targets are listed, go to
Step 5
.
5. If you are unable to determine if a power supply is faulty, seek further
information.
See
“Detecting and Managing Faults” on page 1
.
Related Information
■
“Determine If a Fan Is Faulty” on page 55
■
“Determine If the Battery Is Faulty” on page 75
->
show -d targets /SP/faultmgmt
->
show -d targets /SP/faultmgmt
/SP/faultmgmt
Targets:
0 (/SYS/PSU0)
->