14
Sun Network QDR InfiniBand Gateway Switch Service Manual for Firmware Version 2.1 • March 2013
■
“System Alarm Targets” on page 15
■
“Component Alarm Targets” on page 15
■
“Oracle ILOM Target Alarm States” on page 16
Related Information
■
“Interpreting Status LEDs” on page 1
■
“Managing Faulty Components” on page 7
■
“Identify Faults in the Oracle ILOM Event Log” on page 12
■
“Evaluating Sensor Alarms” on page 17
■
“Accessing CLI Prompts” on page 34
▼
Display the General Alarm State of Systems and
Components
1. Access the Oracle ILOM CLI.
See
“Access the Oracle ILOM CLI (NET MGT Port)” on page 35
.
2. Type.
where
target
is from the tables in
“System Alarm Targets” on page 15
and
“Component Alarm Targets” on page 15
.
For example, to display the general alarm state of fan 1, type.
3. Compare the value displayed to the alarm states.
See
“Oracle ILOM Target Alarm States” on page 16
.
4. If the alarm state is
major
or
critical
, you might need to replace the
component.
See
“Clearable Fault Targets” on page 11
for servicing links.
->
show
target
alarm_status
->
show /SYS/FAN1 alarm_status
/SYS/FAN1
Properties:
alarm_status = cleared
->