Available Connections
Use the information in this topic to plan for these connections. Then gather the required
network addresses and cables.
Caution -
To comply with NEBS lightning requirements, all I/O connections (except the
Ethernet and power connections) must be made using shielded cables, and both ends of the
shield must be grounded.
Caution -
All data cable connections are restricted to intra-building interfaces and must be
isolated from the exposed outside plant cabling. Using primary protectors does not eliminate
this restriction. Ensure that these connections do not connect metallically to interfaces that
connect to the outside plant or its wiring.
This figure and table describe available ports and lists what you need to use them.
No.
Port
Description
Needed
1
USB
Provides USB connection to the host. Additionally, two
USB ports are available on the front of the server.
■ USB keyboard
■ USB mouse
.
2
NET (0 - 3)
Four 10 Gigabit Ethernet ports enable you to connect the
server to your network.
■ An Ethernet cable to connect to the NET 0 port to
your network.
■ Network parameters such as an IP address (can be
provided by DHCP services or assigned a static
address in the OS).
■ Additional cables and Ethernet addresses as
needed for additional connections to NET 1 - 3.
.
62
Netra SPARC S7-2 Server Installation Guide • January 2017
Содержание Netra SPARC S7-2
Страница 1: ...Netra SPARC S7 2 Server Installation Guide Part No E73206 03 January 2017 ...
Страница 2: ......
Страница 8: ...8 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Страница 10: ...10 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Страница 26: ...26 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Страница 60: ...60 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Страница 96: ...96 Netra SPARC S7 2 Server Installation Guide January 2017 ...
Страница 102: ...102 Netra SPARC S7 2 Server Installation Guide January 2017 ...