Fan Speed Alarms
The following table lists the fan speed alarm.
Table A-3 Fan Speed Alarm Information (cont.)
Alarm Name Alarm
ID
Alarm Severity
Causes
Example Log
Message
Graphic Display
Window
Message
FAN
STOPPED
65537 CRITICAL: any fan speed is
<50%.
MAJOR: speed of two or more
fans is
> 75% and < 90%. Or speed of
one fan is >50% and <75% and
the other two fans are at normal
speed.
MINOR: speed of one fan> 75%
and <90%, the other two fans are
at normal speed
Fan
failure.
Fan speed:
XXXX XXXX
XXXX
where xxxx
xxxx xxxx is
the revolutions
per minute
(RPM) of each
fan on the fan
module
Fan stopped
Environmental Sensor Alarm
The following table lists the environmental sensor alarm.
Table A-4 Environmental Sensor Alarm Information (cont.)
Alarm Name
Alarm
ID
Alarm Severity Cause(s)
Example Log
Message
Graphic Display
Window
Message
ENVIRONME
NTAL
SENSOR
FAILURE
65539 CRITICAL
The environmental
sensor component
cannot detect fan
speed and
temperature.
Hardware monitor
failure! Unable to
monitor fan speed
and temperature!
HW Monitor
Fail
Link and SDP Alarms
Link alarms are generated when a network cable is plugged into or unplugged from a
configured network interface. For each possible network interface, an alarm exists that
indicates whether the link goes up or down.
The following tables list detailed information about the Acme Packet 1100 link alarms,
including their ID assignments, severities, causes, log messages, and messages printed in the
graphic display window.
Media Ethernet Link Alarms
The following table lists the Ethernet interface link up/link down alarms.
Appendix A
Link and SDP Alarms
A-2