background image

DEFECT

The machine does 
not switch on

The display does not indicate 
a temperature

The device does not achieve a
desired temperature or exceeds
it significantly.

Pale dots appear within hot
stamped inscription

Stamped letters are blurred,
traces of paint are visible
beyond letter edges

POSSIBLE CAUSE

Temperature of the room 
is lower than +8 C/46,4 F

The plug is not connected to mains

Lack of voltage in a socket

The device is damaged

Check what  temperature 
has been set
The device is damaged

Too low temperature

Too short time of stamping

Too low pressure

Too high temperature

Too long time of stamping

Too high pressure

REMEDY

Place the machine in a room
temperature higher than
+8C/46,4 F

Insert the plug to mains socket

Connect the machine to another socket

Contact the supplier

Set a suitable temperature

Contact the supplier

Increase temperature

Increase stamping time

Increase the pressure 
(turn clockwise the knobs of the
basic plate (3)

Reduce temperature

Reduce stamping time

Lower the pressure 
(turn counter-clockwise 
the knobs of the basic plate (3)

25.04.05

Содержание Goldpress Plus

Страница 1: ...Goldpress 4 OPERATING MAINTENANCE AND SAFE USAGE MANUAL OF THE GOLDPRESS 4 MACHINE...

Страница 2: ...or before replacing the machine the plug should be removed from a mains socket Before removing the housing from the machine remove the plug from a socket necessarily The power pack module is installe...

Страница 3: ...t and storage The GoldPress is an office device electri cally supplied and adapted to operation in office conditions Both the machine and its package should not be exposed to moisture e g rain If mois...

Страница 4: ...rature 100 C 212 F set stamping time 1 5 2 seconds However if the stamping results are not satisfactory a change in the settings may be necessary To set the heater temperature move the arm maximally u...

Страница 5: ...the bottom If you prepare fonts to be hot stamped on the channels use only 5 5 mm or 6 mm ones Using smaller fonts may result with their damage For 6 mm fonts use only 1L6 frame with 1 line For 5 5 m...

Страница 6: ...uct a test to check if the matrix is hot enough Preparing the document for hot stamping 1 Center a cover with the ruler located along the drawer edge 2 Determine the height of the inscription using th...

Страница 7: ...ducted every time when changing the fonts or type of cover It should be repeated only after the hot stamping result is not satisfactory B ARRANGING THE PLATES DEPEND ING ON THE TYPE OF COVER Metalbin...

Страница 8: ...new text or mounting a new matrix Note After hot stamping is done we recommend to wipe the hot stamped inscription with a soft cloth in order to get rid of the remainings of hot stamping foil Maintena...

Страница 9: ...d Check what temperature has been set The device is damaged Too low temperature Too short time of stamping Too low pressure Too high temperature Too long time of stamping Too high pressure REMEDY Plac...

Отзывы: