Basics of glass measurement
39
-
5.2 Influence of different measuring wavelengths
Spectral range
Sensor (Examples)
Purpose
8 - 14 µm
PI 640i, Xi 400
Low temperature, uncoated glass
7.9 µm
PI 640i G7, CTlaser G7
High temperature, coated glass
5.0 µm
CTlaser G5
1.0 µm
PI 1M
molten glass,
looking in/through glass
The table gives an overview for which purpose which wavelength and therefore which sensor must be used.
This depends, among other things, on the material, the temperature and the coating.
Содержание Top-down GIS
Страница 1: ...Operators Manual Top down GIS Glass Inspection System ...
Страница 5: ... Table of contents 5 Appendix A Control cabinet 43 ...
Страница 11: ... Technical Data 11 Figure 1 Dimensions mm shutter system ...
Страница 12: ... 12 Figure 2 Dimensions mm switch cabinet ...
Страница 19: ... Technical Data 19 CT G5L SF optics ...
Страница 34: ... 34 Figure 16 Linescan in PIX Connect software ...
Страница 43: ... Appendix A Control cabinet 43 Appendix A Control cabinet Figure 24 Wiring diagram of control cabinet ...
Страница 48: ...Top down GIS MA E2021 07 A ...