EDFA optical amplifier – user manual
52
AM
{cr}
Reports the EDFA Mode
.
Example usage:
AM{cr}
Reply is:
AM:{sp}O{cr}
EDFA operates in OFF mode. In OFF mode, the laser diode driving current
are set to 0 mA, alarms are disabled, and TEC are enabled.
or Reply is:
AM:{sp}G{cr}
EDFA operates in AGC mode.
or
Reply is:
AM:{sp}C{cr}
EDFA operates in ACC mode.
APC
{sp}[1,2]{sp}<value>{cr} Set the output power in APC mode for each stage.
Example usage:
APC{sp}1{sp}11{cr}
Reply is:
APC{sp}1{sp}11{cr}
the output power for stage 1 in APC mode is set to 11 dBm.
APC
{cr}
Report the output power in APC mode for each stage.
Example usage:
APC{cr}
Reply is:
APC{sp}1:{sp}10 dBm{cr}
APC{sp}2:{sp}17 dBm{cr}
the output power for stage 1 in APC mode is set to 10 dBm, the output power
for stage 2 in APC mode is set to 17 dBm.