![Optiview VR Enterprise Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/optiview/vr-enterprise/vr-enterprise_user-manual_1643826039.webp)
DVR Server Manual ver.6.05/rel.120909
33
2.1.2
Network setup
【
Remote Connection
】
Used for network connections.
If set to
―disable‖,
it will not permit any clients to connect to this DVR system.
【
Remote Disp Use Port
】
Select remote connection port for Clients.
【
Net Send Priority
】
There are three items for selection.
―Smooth‖
requires that the receiving system has a large buffer. Setting this option to
―Real Time
"
requires that the receiving system has enough bandwidth,
otherwise, the data will appear off and on when it is sent from the network.
【
PDA Connection
】
Select whether to allow PDA connections to the
DVR system or select
―disable‖ to prevent the connection of any PDA devices.
Note: To use PDA connection normally, the board card should support dual compression
and user must set dual setting in local setup (can‟t set remote image same as recording).
【
PDA Connect Port
】
Select remote connection port for PDA devices.
【
Alarm Auto Connect
】
Assign a network client to receive alarm
messages when there is an alarm. The alarm channel image will
automatically display in the client software, but users must be sure that clients
are running on that IP address.
*Note:
Alarm auto connection to an IP is used to input alarm automatically. When the sensor is set to
normal or motion record and there is IP address setup, the system will check if the client has
connected with this system. If there is no connection, the system will try to connect with it
through Port 5300 (preset). If it cannot connect, the system will keep trying until the connection
is OK. Please ensure that your client‟s program is in use, that Port 5300 is listening and the
network is in good condition. If it is not, the system will not be stable.
【
Alarm Send Port
】
This is the alarm message connecting port, which
is used to send an alarm from the DVR Server to a Client.
【
Web Server Port
】
connecting port. Default value is 80 for
http access; but for some Windows XP editions, port 80 is shielded. In this
case, users should modify this port to another port, such as 81. After that the
DVR server must be rebooted. A user can access the DVR server via IE
Client by specifying the port, for example; http://xxx.xxx.xxx.xxx:80
where ‗x‘
equals the IP address (IP can be a static IP or dynamic domain name).
【
If Use DNS
】
Select to use DNS or not, supports dynamic IP.
【
Local Host Name
】
Input the name description for DNS Server
identification.
【
DNS Server IP
】
DNS server host IP.
【
DNS Connection Port
】
DNS server host port, it is used to connect to a
DNS server.
DNS server work mode:
If it is required, please obtain the DNS server software from developer.