OptiPure OP175 Скачать руководство пользователя страница 6

OP175 System Installation, Operation & Maintenance 

6

 Wall Mounting

The processor unit should always be mounted where 

it is well-supported, either using anchors in a cement 

wall, or using the support of studs in a wall-board 

wall. 

Never mount it directly to sheet-rock alone.

 

Instead, mount it on a sheet of plywood which is 

anchored to the wall studs, as shown above.

Four user-supplied bolts or screws with a head 

diameter of approximately 1/2” (which will fit into the 

keyholes in the system bracket, but will not slip out 

when tightened) should be used to hang the system. 

This will allow the unit to be lifted off the bolts, if 

necessary for maintenance, without removing all 

the bolts from the wall. Hold the processor in place 

(without the cartridges) to mark the locations for 

the screws.  BE SURE TO ALLOW 3” BELOW THE 

CARTRIDGES TO ALLOW FOR REMOVAL.  Screw 

the four bolts or screws in place, leaving approximately 

1/4” clearance between the bottom of each bolt head 

and the wall. Position the system over the mounting 

bolts, and let the bracket slip down into the keyholes. 

Tighten all screws.

 System Installation

Note: Do not install the cartridges in the processor 

until completing this section. Do not plug in the 

power cord from the RP pump until completing the 

following section, “System Start-Up”.
Refer to “Typical Installation” diagram on page 5 

and “How to Use Our Quick-Connect Fittings” on 

page 16 when making the following connections.

A feed water ball valve and pressure gauge (user 

supplied) should be installed to provide water to the 

system FEED WATER INLET with the green tubing 

(supplied). Hose, tubing and fittings for making 

connections between the processor, storage tank 

and drain are supplied in the installation kit with the 

system.

1.  Remove the tank lid. Inside the tank, the float 

valve may be secured for shipping. Remove any 

wrapping on the float to allow it to hang and move 

freely.

2.  DRAIN: Connect the 1/4” black tubing from the 

installation kit to the REJECT WATER OUTLET on 

the processor. Run the line to an appropriate drain. 

Observe local plumbing codes and supply an 

appropriate air gap. (Any fittings for connecting to 

the drain will need to be supplied by the customer.) 

Fix tubing in place at the drain.

3.  FEED WATER: Apply 3 ‘wraps’ of Teflon tape to 

the 1/2” FPT x 3/8” push-connect fitting (supplied). 

Screw the fitting into the Feed Water Supply Ball 

Valve and tighten (DO NOT OVERTIGHTEN). 

Connect one end of the 3/8” GREEN TUBING to 

this fitting. Connect the other end of the tubing to 

the FEED WATER INLET located on the left side 

of the Processor. Cut the tubing to the required 

Plywood anchored 

to wall

10.7”

Outside edge of 

processor bracket

17.2”

9.1”

15.2”

Содержание OP175

Страница 1: ...Installation Operation Maintenance Manual Rev 1 Manufactured By OptiPure Div of Procam Controls Inc 2605 Technology Drive Bldg 300 Plano TX 75074 P 972 881 9797 F 972 422 6262 OP175_manual_v1 indd 201...

Страница 2: ...gree II 7 Indoor use only protect from elements Explanation of Symbols The following symbols are used on the water processor The symbols and their explanation is given below Earth ground WARNING Hazar...

Страница 3: ...rating Pressure Gauge Membrane Reject Water Tubing Connection AMS QT15 Membrane Cartridge Reject Water Outlet 1 4 Push to Connect Connect to drain per local regulations 1 2 3 4 Optimized Water to Stor...

Страница 4: ...ted within 5 feet of the location of the unit Drain must allow a minimum flow of 2 gallons per minute Compliance with most local plumbing codes requires installation of an approved air gap in the drai...

Страница 5: ...Gauge Membrane Reject Water Tubing Connection AMS QT15 Membrane Cartridge Water Quality Monitor Optimized Water to Storage Tank Inlet on Valve Repressurization Assembly Outlet Hose Barb Repressur izat...

Страница 6: ...mp until completing the following section System Start Up Refer to Typical Installation diagram on page 5 and How to Use Our Quick Connect Fittings on page 16 when making the following connections A f...

Страница 7: ...nsions IMPORTANT ALLOW A MINIMUM OF 24 IN FRONT OF THE PROCESSOR FOR MAINTENANCE AND SERVICE DO NOT MOUNT SYSTEM ABOVE THE CEILING OR IN A LOCATION THAT IS NOT EASILY ACCESSIBLE WHEN THE 16 GAL TANK A...

Страница 8: ...e connection between the 1 2 hose and distribution line but for now leave the line loose and route the loose end of the gray hose into a drain or bucket make certain the hose length will reach the sto...

Страница 9: ...ump will run more smoothly and the water flow from the gray hose will become steady 4 Unplug the RP Pump cord Connect to Equipment You are almost ready to enjoy the benefits of Optimized Water All tha...

Страница 10: ...on to drain The pure water stream continues through the Permeate Check Valve 8 and through the Mineral Addition cartridge 2 then on to the tank through the Tank Inlet Divert Valve 11 on top of the St...

Страница 11: ...the ability to measure membrane production by closing the Buffer Tank Valve 17 and turning the Tank Inlet Divert Valve 11 to the bypass or UP position This diverts the permeate pure water produced by...

Страница 12: ...lve PN 524 20010 Pressure Gauge PN 530 20018 Reject Flow Control PN 564 02105 OUT Permeate Conductivity Probe Pressurized Water Check Valve PN 524 01035 Sample Port Valve PN 520 12223 Permeate Check V...

Страница 13: ...ge Tank PN 570 00016 Air Breather PN 300 40005 RP Pump PN 704 35513 Tank Bracket PN 594 80516 Buffer Tank PN 340 50001 Buffer Tank Valve PN 520 14501 Optimized Water Inlet Connect line from Optimized...

Страница 14: ...d pushing up then turn a quarter turn to the right 5 If it is necessary to replace the Mineral Addition Cartridge repeat steps 4 5 for the Mineral Addition Cartridge 6 Install a piece of 3 8 tubing in...

Страница 15: ...rt valve open the Sample Port and direct to a bucket or drain Turn the Tank Inlet Divert Valve to the Bypass or UP position Open the Water Supply Valve and put the Emergency Bypass Valve in the SERVIC...

Страница 16: ...Push tubing straight in Resistance will be felt when the tubing meets the O ring The outside of the tubing must be free of knicks and gouges Cut tubing with a plastic tubing cutter or a razor knife Ma...

Отзывы: