OP175 System Installation, Operation & Maintenance 

4

 Installation Requirements

This section and the next provide the water, electrical 

and space requirements for the OP175. 

Pay 

special attention to the feed-water chemistry 

requirements. 

Operating a system on water supplies 

outside of these parameters may lead to premature 

membrane failure. This product is for commercial 

use only and must be installed and maintained in 

accordance with manufacturer’s guidelines and local 

regulatory plumbing and electrical codes.

Operating parameters

Typical Membrane TDS* rejection:   

   

97+% 

Feed Temperature: 

40 - 100° F (4 - 38° C)

Feed pressure: 

50 - 80 psi  

 

 

(3.4 - 5.9 bar) at 1 gpm

Production** 

(

at 77°F, 60 psi

)

 

  

 

184 gals/day, 

 

  

 

7.7 gals/hr, 0.13 gpm 

Recovery: 

up to 33%.

IMPORTANT NOTE:

 The nominal production rate 

is strictly dependent on feed water temperature 

and pressure.  Reduced temperature or pressure 

will reduce production. For example: Operating 

pressure of 30 psi will cut production by 50%. 48˚F 

feedwater will cut production by 50%. 

 

Location

The system should be installed indoors, in the 

proximity of the equipment (within 25 feet) and 

protected from the elements.  Do not let the processor 

or storage tank freeze or be exposed to rain or direct 

sunlight.

Post-treatment

Treated water stored in a tank may absorb organic 

compounds from the tank, which can affect water 

taste and odor. If product water is for consumption, an 

optional post-treatment filter, such as an OptiPure 

 

FX or QT carbon filter, should be installed after the 

tank. If used, it is best installed as close to the point of 

use as possible. Other specialized post-treatment is 

also available.

Feed water connection

An adequate flow and pressure of water to the unit is 

essential for successful operation. Provide a dedicated 

1/2” water line to the vicinity of the installation. Install 

a full-flow ball valve and pressure gauge with 1/2” 

female pipe thread (user supplied) for connection to 

installation hardware provided with the system. A 1/2” 

male pipe thread x 3/8” push-to-connect adapter is 

included in the installation kit.

 

Drain

A drain should be located within 5 feet of the location 

of the unit. Drain must allow a minimum flow of 2 

gallons per minute. Compliance with most local 

plumbing codes requires installation of an approved air 

gap in the drain line. The drain connection should be 

accessible for system set-up and service.

Electrical requirements

A power source should be located within 5 feet of the 

location of the unit. 
RP Pump 

120V 60Hz 2 Amps

Feed-water chemistry

Feed TDS 

Up to 1200 ppm

Feed pH 

6 - 10

Hardness 

28 grains or less

Free chlorine 

<2 mg/l

Iron (Fe) 

0.1 mg/l max.

Turbidity  

<0.05 NTU

Manganese 

0.05 mg/l max.

Hydrogen sulfide 

0.0 mg/l

 

A water analysis must be conducted before installing 

the system or the information requested above can 

be obtained from your local water utility. If your water 

analysis shows that any of these parameters are not 

within range, additional pretreatment and/or higher 

frequency of maintenance may be required. Contact 

your OptiPure distributor for assistance. The presence 

of silica or flocculants such as alum or cationic 

polymers in the feedwater may cause membrane 

fouling and may require special chemical pretreatment 

or periodic membrane cleaning. Please note that 

membrane failure due to fouling is not covered by the 

warranty.

Storage Tank

The tank must be located within 10 feet of the water 

processor unit. The floor beneath the storage tank 

should be smooth, clean and free of sharp objects that 

could puncture the bottom of the tank. 

Note: The tank 

is atmospheric, with a sub-micron, hydrophobic air 

breather filter.

Optimized Water Lines to Equipment

Tubing, piping and associated fittings connecting 

Optimized water lines to equipment shoud be food 

grade material that meets NSF Std 51 or 61 with a 

minimum pressure rating of 75 PSI.  Optimized water 

may react with most metal piping imparting a bad 

taste. Plastic pipe or reinforced opaque beverage 

tubing are acceptable choices for Optimized water 

distribution.  The larger inside diameter tubing or hose, 

the better to minimize pressure drop.

*TDS (total dissolved solids) create conductivity in water and are 

expressed in ppm or mg/l (parts per million or milligram per liter). 

**Nominal production @ 77°F (25°C) @ 500 ppm based on a 24 

hr day. Actual production will vary based on variations in water 

temperature, pressure, and TDS.

Содержание OP175

Страница 1: ...Installation Operation Maintenance Manual Rev 1 Manufactured By OptiPure Div of Procam Controls Inc 2605 Technology Drive Bldg 300 Plano TX 75074 P 972 881 9797 F 972 422 6262 OP175_manual_v1 indd 201...

Страница 2: ...gree II 7 Indoor use only protect from elements Explanation of Symbols The following symbols are used on the water processor The symbols and their explanation is given below Earth ground WARNING Hazar...

Страница 3: ...rating Pressure Gauge Membrane Reject Water Tubing Connection AMS QT15 Membrane Cartridge Reject Water Outlet 1 4 Push to Connect Connect to drain per local regulations 1 2 3 4 Optimized Water to Stor...

Страница 4: ...ted within 5 feet of the location of the unit Drain must allow a minimum flow of 2 gallons per minute Compliance with most local plumbing codes requires installation of an approved air gap in the drai...

Страница 5: ...Gauge Membrane Reject Water Tubing Connection AMS QT15 Membrane Cartridge Water Quality Monitor Optimized Water to Storage Tank Inlet on Valve Repressurization Assembly Outlet Hose Barb Repressur izat...

Страница 6: ...mp until completing the following section System Start Up Refer to Typical Installation diagram on page 5 and How to Use Our Quick Connect Fittings on page 16 when making the following connections A f...

Страница 7: ...nsions IMPORTANT ALLOW A MINIMUM OF 24 IN FRONT OF THE PROCESSOR FOR MAINTENANCE AND SERVICE DO NOT MOUNT SYSTEM ABOVE THE CEILING OR IN A LOCATION THAT IS NOT EASILY ACCESSIBLE WHEN THE 16 GAL TANK A...

Страница 8: ...e connection between the 1 2 hose and distribution line but for now leave the line loose and route the loose end of the gray hose into a drain or bucket make certain the hose length will reach the sto...

Страница 9: ...ump will run more smoothly and the water flow from the gray hose will become steady 4 Unplug the RP Pump cord Connect to Equipment You are almost ready to enjoy the benefits of Optimized Water All tha...

Страница 10: ...on to drain The pure water stream continues through the Permeate Check Valve 8 and through the Mineral Addition cartridge 2 then on to the tank through the Tank Inlet Divert Valve 11 on top of the St...

Страница 11: ...the ability to measure membrane production by closing the Buffer Tank Valve 17 and turning the Tank Inlet Divert Valve 11 to the bypass or UP position This diverts the permeate pure water produced by...

Страница 12: ...lve PN 524 20010 Pressure Gauge PN 530 20018 Reject Flow Control PN 564 02105 OUT Permeate Conductivity Probe Pressurized Water Check Valve PN 524 01035 Sample Port Valve PN 520 12223 Permeate Check V...

Страница 13: ...ge Tank PN 570 00016 Air Breather PN 300 40005 RP Pump PN 704 35513 Tank Bracket PN 594 80516 Buffer Tank PN 340 50001 Buffer Tank Valve PN 520 14501 Optimized Water Inlet Connect line from Optimized...

Страница 14: ...d pushing up then turn a quarter turn to the right 5 If it is necessary to replace the Mineral Addition Cartridge repeat steps 4 5 for the Mineral Addition Cartridge 6 Install a piece of 3 8 tubing in...

Страница 15: ...rt valve open the Sample Port and direct to a bucket or drain Turn the Tank Inlet Divert Valve to the Bypass or UP position Open the Water Supply Valve and put the Emergency Bypass Valve in the SERVIC...

Страница 16: ...Push tubing straight in Resistance will be felt when the tubing meets the O ring The outside of the tubing must be free of knicks and gouges Cut tubing with a plastic tubing cutter or a razor knife Ma...

Отзывы: