  DVA-102ETH version 1.2 

 

R&D Department  

 

DVA-102ETH 

Digital voice announcer  

and Optimax system gateway 

ATTENTION: 
When the unit starts to run, the dipswitches IP address is 
automatically saved in the DVA-102ETH flash memory. To 
change the address, it is necessary to delete first the IP 
address which is saved in the flash memory. 

5.

 

CONFIGURATION OF THE IP ADDRESS OF THE UNIT 

On the back of the unit there are some DIP switches by means of which the IP address can be configured manually. 

 

 

This address identifies the unit in the network, so each unit must have a unique IP address. 
An IP address is represented by means of a 32-bit binary number. The IP addresses are expressed as decimal notation 
numbers:  the  32  bits  of  the  address  are  divided  into  four  octets  (an  octet  is  a  group  of  8  bits).  Each  octet  is 

represented by A0 to A7 for the first octet, B0 to B7 for the second octet, C0 to C7 for the third octet and D0 to D7 for 

the fourth octet.  
Each bit can have the value 0 (DIP switch OFF) or 1 (DIP switch ON). In order to obtain the decimal value of the octet, 

the decimal values of each bit that is in the ON position must be added up (from the top down: 1, 2, 4, 8, 16, 32, 64 

and 128). 

5.1.

 

UNIT IP ADDRESS CONFIGURATION BY MEANS OF DIPSWITCHES 

1.  Switch off the unit. 
2.  Set the required address in the 

IP Config

 dipswitches. Table 

II on the next page shows all the DIP switch combinations 

from 0 to 255. 

3.  Switch on the unit. 
Figure 3 shows an example in which the IP address 

192.168.100.128 is configured. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.2.

 

DELETE THE IP ADDRESS BY MEANS OF DIPSWITCHES 

1.  Switch off the unit. 

2.  Set the 0,0,0,0 address in the 

IP Config

 dispswitches. 

3.  Switch on the unit and after 15 seconds, switch it off. The IP address saved in the flash memory has been deleted. 
 

 

NB: The IP address can also be set by software. To do so, refer to section 5.3.

 

Figure 3 

Содержание DVA-102ETH

Страница 1: ...9I301 29 11 10 ...

Страница 2: ......

Страница 3: ...ION OF CONTACTS 22 8 3 1 CREATION OF DVA 102ETH ANALOG ZONES 23 8 4 CONNECTING THE EQUIPMENT IN THE INSTALLATION STRUCTURE 23 8 5 ASSIGNING THE DVA 102ETH TO A SERVER PC 24 8 6 SENDING CONFIGURATIONS TO THE UNIT 24 8 7 EDITING THE CONFIGURED PARAMETERS 24 9 PRE RECORDED MESSAGES 25 10 OPERATIONS FROM THE FRONT CONTROLS 27 10 1 MENU STRUCTURE 27 10 2 OPERATIONS FROM THE DVA 102ETH MENU 28 10 2 1 CH...

Страница 4: ...eway 11 3 DVA 102ETH AND ANALOG ZONES ACTIVATED BY CONTACT 34 11 4 DVA 102ETH AND ANALOG ZONES ACTIVATED BY CONTACT WITH LOUDSPEAKER LINE SURVEILLANCE 37 12 NETWORK SPECIFICATIONS 39 13 STECHNICAL SPECIFICATIONS 41 14 SOFTWARE AND FIRMWARE VERSIONS 41 15 DOCUMENT VERSION TRACKING 41 16 GUARANTEE 42 ...

Страница 5: ...nomously as a source of messages towards analog power units or as a link between an installation in an OPTIMAX network and conventional PA systems with analog power units In the latter case it supports Reception of audio via IP and transmission of this through the analog audio output Playing of pre recorded messages from the Compact Flash card and transmission of these through the analog audio out...

Страница 6: ...age Lights when an emergency message is played Priority Lights when an emergency message with priority is played Program Lights when an emergency message without priority is played 11 Ethernet B input status indicators RX When lit it indicates that data is being received through the ETHERNET B input TX When lit it indicates that data is being transmitted through the ETHERNET B input 10 Mb Indicate...

Страница 7: ...or Analog local input balanced with an RJ45 connector and a sensitivity of 0 dBm especially suitable for receiving emergency announcements It takes priority over any other signal ETH inputs AUDIO INPUT and pre recorded messages To connect it refer to section 7 3 14 FAIL relay This is activated when the unit is switched off when a failure in the Ethernet connection is detected or an internal commun...

Страница 8: ...2ETH Digital voice announcer and Optimax system gateway 4 CONFIGURATION OF THE RS485 ADDRESS On an RS485 BUS each unit must have a different address Table I shows the configuration of the RS485 ADDRESS DIP switches and their possible values Table I ...

Страница 9: ...ented by A0 to A7 for the first octet B0 to B7 for the second octet C0 to C7 for the third octet and D0 to D7 for the fourth octet Each bit can have the value 0 DIP switch OFF or 1 DIP switch ON In order to obtain the decimal value of the octet the decimal values of each bit that is in the ON position must be added up from the top down 1 2 4 8 16 32 64 and 128 5 1 UNIT IP ADDRESS CONFIGURATION BY ...

Страница 10: ...DVA 102ETH version 1 2 R D Department 10 DVA 102ETH Digital voice announcer and Optimax system gateway TABLE II ...

Страница 11: ...paragraph 8 It is possible to change the IP configuration of the unit by means of the IP ADDRESS DIP switches on the back of the unit or remotely without the need for access to the unit through the P A Manager software To make the change by software right click with the mouse on the name of the DVA 102ETH on the message panel and select the option Web Connection 1 If the PC is remote with respect ...

Страница 12: ...ontact of the EMERGENCY INPUT connector to the output priority contact of the AUDIO OUTPUT connector J6 positioned Priorities connected factory configuration J6 not positioned Priorities independent Dipswitch SW3 DIPSWITCH 1 ON DIPSWITCH 2 OFF GND on PIN 8 of the EMERGENCY INPUT connector factory configuration DIPSWITCH 1 OFF DIPSWITCH 2 ON ALARM indicator contact on PIN 8 of the EMERGENCY INPUT c...

Страница 13: ... For its connection refer to Figure 6 Pin 1 Audio H Hot Pin 2 Audio C Cold Through contacts 1 and 2 this input can provide a PHANTOM type power supply of 24 V DC See section 6 INTERNAL CONFIGURATIONS Pin 3 Acknowledge This output contact allows synchronisation with external desks MD 94 family avoiding initial signal loss from the desk due to possible delays in activation Pin 6 Priority input conta...

Страница 14: ...tivated For its connection refer to Figure 7 Pin 1 Audio H Hot Pin 2 Audio C Cold Through contacts 1 and 2 this input provides a PHANTOM type power supply of 24 V DC see section 6 to power the emergency desk Pin 3 Acknowledge Allows synchronisation with external desks MD 94 family avoiding initial signal loss from the desk due to possible delays in activation Figure 8 shows an example of ACK opera...

Страница 15: ...s which can be configured by means of the P A Manager software To activate a contact this contact must be grounded These inputs are used for Local pre recorded message activation When the input contact is activated a pre recorded message is sent from the DVA 102ETH to one or several zones Zone selection When the input contact is activated a destination zone is pre selected When the priority of the...

Страница 16: ...te the zone selection commands received via Ethernet into RS485 commands by Polling in installations with UDCE 01 zones and by CSMA in installations with UMX 02 zones Receive system alarms via RS485 display them on the front LCD screen and communicate them to other units with an ETHERNET connection DC 600ETH FC 600ETH RJ45 connectors with a metal housing are used for the RS485 connection If the un...

Страница 17: ...A 102ETH can be configured here see section 8 3 3 Connect the equipment to the installation structure see section 8 4 4 The DVA 102ETH must be associated with the Server PC see section 8 5 5 Send the configurations to the unit see section 8 6 8 1 GENERAL CONFIGURATION 1 Name Enter a name to identify the unit maximum of 20 characters RS485 PARAMETERS 2 Address Every equipment unit connected to an R...

Страница 18: ... see Notes on Local and Global Co ordinators on page 19 13 RS485 Gateway Enable this function in installations in which the DVA 102ETH is connected to another equipment unit by means of the RS485 bus If there is more than one DVA 102ETH connected to the RS485 bus only one of them will have the RS485 Gateway function activated 14 Associated Audio Input Used on DVA 102ETH units whose AUDIO OUT outpu...

Страница 19: ...ows 1 From the installation screen open the Options menu and select Multicast Configuration 2 A window with the configurations of the multicast group appears Double click on the data item that you wish to change 3 Modify the value and click on Accept 4 Confirm the change by clicking on Yes 5 Close the multicast configuration window by clicking on OK ATTENTION The values that are modified from the ...

Страница 20: ... data may circulate freely across the network This function is performed by two applications one at a local level known as LCC which manages the digital channels at PA Area level and another known as GCC which manages the digital channels at a global level between different PA areas and or servers Each PA Area needs at least one LCC process on one of its equipment units If there is more than one P...

Страница 21: ...operations such as sending pre recorded messages and viewing the status of the volume Operator With password by default 1234 In addition to all the operations available to the basic user the zone volume can be modified Administrator With password by default 1234 Without any restriction COMPACT FLASH MESSAGES Volume controls for the pre recorded messages resident in the Compact Flash memory of the ...

Страница 22: ...from the DVA 102ETH to one or several zones The message and the zones are configured by means of the Message and Zones drop down menus that appear when this functionality is selected Also configure the Activation Mode choosing between Pulse and Level If pulse is configured a pulse is required to activate the message and another pulse is required to stop it The duration of the pulse must be at leas...

Страница 23: ...e the contacts assigned are shown in green These contacts will be activated whenever a live voice or pre recorded message is sent from a unit in the installation to this analog zone The contacts that appear in grey are output contacts already used by another analog zone 8 4 CONNECTING THE EQUIPMENT IN THE INSTALLATION STRUCTURE When equipment units are added to the installation they appear in the ...

Страница 24: ... click on Save 2 On the installation tree right click with the mouse on the DVA 102ETH that has just been configured and select the option Send Configurations 3 A progress bar appears Upon completion click on OK You can exit the installation screen by opening the File menu and selecting Exit The P A Manager software will restart automatically 8 7 EDITING THE CONFIGURED PARAMETERS If required the c...

Страница 25: ... Recording onto the memory by means of a Compact Flash card reader 1 Remove the memory from the DVA 102ETH and position it in a Compact Flash memory card reader connected to the PC that contains the files 2 Use the PC browser to copy the files from the computer to the memory which will be shown as an additional disk unit 3 Put the memory back into the DVA 102ETH B Recording onto the memory inserte...

Страница 26: ... recorded Message Management DVA 3 Locate the message whose parameters you wish to change If it is a local message click on the Local Messages tab 1 select the name of the DVA 102ETH 2 from the drop down menu and then select the message To make a multiple selection hold the Ctrl key down If the message is one of the Common Messages click on the Common Messages tab 3 and select the message In this ...

Страница 27: ...ser to the previous menu on the same level Starts or activates the menu option selected 10 OPERATIONS FROM THE FRONT CONTROLS Through the front controls and the LCD screen it is possible to perform some basic operations Monitor messages of the DVA 102ETH Modify program and priority volumes of the DVA 102ETH Record DVA 102ETH messages View system alarms Use the navigation keys to view and select th...

Страница 28: ...Press until you see the option STOP ACTIVE CHANNEL on the screen 3 Press OK 10 2 4 RECORD A MESSAGE FROM THE DVA 102ETH 1 Connect a microphone to the front recording input of the DVA 102ETH 2 From the start screen press 3 Press until you see the option ACQUISITION MICROPHONE on the screen 4 Press to enter the menu 5 Press OK to start recording 6 Press OK to stop recording 7 Press OK option OK to s...

Страница 29: ...until you see the option CONFIGURATIONS on the screen 3 Press to enter the CONFIGURATIONS menu 4 Press until you see the option Modify CF PRIORITY volumes on the screen 5 Press to view the priority volumes 6 Select the volume that you wish to modify by means of the and keys 7 Situate the volume in the desired position by means of the and keys 8 Press OK This volume affects the audio of the AUDIO O...

Страница 30: ...ts Sending pre recorded messages from the DVA 102ETH to the power units by activating the input contacts of the DVA 102ETH in the diagram CTI 1 and CTI 2 Sending pre recorded messages from the DVA 102ETH to the power units activating these from the PC Sending digital audio from the desk to the power units Reception of system incidents and alarms by the PC the DVA 102ETH and the DC 600ETH desk Surv...

Страница 31: ...the DVA 102ETH to the power units Selection of zones from the DC 600ETH desk and from the PC using RS485 communication between the DVA 102ETH and the UMX 02 0 The DVA 102ETH translates the zone selection commands received via Ethernet into RS485 commands In this way the UMX 02 0 receives the commands and activates the outputs corresponding to the zones selected Through the configuration of the inp...

Страница 32: ...2ETH is connected as the associated input The audio input of the UMX 2E card must be configured beforehand Establish the RS485 address this address must coincide with the value of the RS485 configuration DIP switch on the back of the DVA 102ETH and the CSMA communicatioon protocol Activate the RS485 Gateway control so that the DVA 102ETH acts as a link between the OPTIMAX system and the analog par...

Страница 33: ...message selected will be sent to the zones configured in the Zones field Configure the input contacts that will be used as zone selection of the MD 94R6 analog microphone in this case contacts 3 4 and 5 assigning them the Zone Selection functionality Assign a zone to the contact The input contact will be activated when the message is started from the MD 94R6 desk Through the RS485 bus the DVA 102E...

Страница 34: ... to the power units activating these from the PC Sending audio from the DC 600ETH desk to the power units digital audio from the desk to the DVA 102ETH and analog audio from the DVA 102ETH to the power units Zone selection from the DC 600ETH desk or from the PC using the output contacts of the DVA 102ETH in the diagram Ct1 Ct2 and Ct3 Through the configuration of the input contacts of the DVA 102E...

Страница 35: ...NSTALLATION STRUCTURE CONFIGURATION Add the analog zones to the DVA 102ETH Configure them assigning a contact to each one Once the analog zones have been configured when the Contacts tab in the configuration of the DVA 102ETH is opened the output contacts already appear in the list of configured contacts ...

Страница 36: ...t When a zone is selected from the MD 94R6 desk one of these input contacts is activated and when the message is started the DVA 102ETH will activate the output contact corresponding to the zone selected Configure the input contacts in this case contacts 1 and 2 assigning them the Local Message Activation functionality Select a message the destination zones and the activation mode When one of thes...

Страница 37: ...ing audio from the DC 600ETH desk to the power units digital audio from the desk to the DVA 102ETH and analog audio from the DVA 102ETH to the power units Zone selection from the DC 600ETH desk or from the PC using the output contacts of the DVA 102ETH in the diagram Ct1 Ct2 and Ct3 Through the configuration of the input contacts of the DVA 102ETH in the diagram contacts 3 4 and 5 an analog microp...

Страница 38: ...3 Establish the RS485 address this address must coincide with the value of the RS485 configuration DIP switch on the back of the DVA 102ETH The communication protocol selected CSMA or POLLING must coincide with the DALA 01 added to the installation DALA 01 CSMA or DALA 01 POLLING Activate the RS485 Gateway control so that the DVA 102ETH acts as a link between the OPTIMAX system and the analog part...

Страница 39: ... scale of the management data sent 1 Default multicast base addresses ports and configurations Broadcast address Broadcast port Initial configuration download 255 255 255 255 3333 Multicast address Multicast port Initial configuration download 239 5 5 5 8001 Multicast address Multicast port Others Control data 239 5 5 5 5000 Heart beat every 10 seconds Global audio channels 239 1 0 x 6000 x 8 simu...

Страница 40: ... in Application Layer Multicast snooping Multicast filtering IGMP v2 For large installations Multicast routing Spanning Tree Capacity to handle TOS Type Of Service 5 Certified hardware Large installations Nortel BayStack 470 Ethernet Routing Switch 3510 and higher Cisco 36XX or higher Alcatel Level 3 switches Medium sized installations NKF XSNET 1800 Hirschmann RS30 0802O6O6SDAEHH01 0 Small instal...

Страница 41: ...scribed in this user s manual are valid for the following software and firmware versions or later versions Hitachi Firmware Version 2 62 P A Manager Software Version 2 6 Revision 3903 20496 Optimus Flasher Software Version 2 6 11 15 DOCUMENT VERSION TRACKING Reference system Type of Document Confidentiality N A Optimax Installation and operation guide Rev Date Modifications Content Written by 1 0 ...

Страница 42: ...improper use of the equipment including lack of maintenance 5 The guarantee shall not be valid whenever the following is observed Amendments or corrections made to the details of the guarantee certificate or purchase invoice Failure to produce the original invoice or the absence of a date on this Absence of the serial or batch number on the equipment 6 In the case of personal computers the guarant...

Страница 43: ......

Страница 44: ......

Отзывы: