DVA-102ETH version 1.2
R&D Department
34
DVA-102ETH
Digital voice announcer
and Optimax system gateway
11.3.
DVA-102ETH AND ANALOG ZONES ACTIVATED BY CONTACT
DESCRIPTION
The PC, the DVA-102ETH and the DC-
600ETH desk are connected to the
Ethernet network.
Three output contacts of the DVA-
102ETH (contacts 1, 2 and 3) are
configured to activate the priority of
the analog power units.
The system supports:
Sending pre-recorded messages
from the DVA-102ETH to the power
units by activating the input contacts
of the DVA-102ETH (in the diagram,
CTI-1 and CTI-2).
Sending pre-recorded messages
from the DVA-102ETH to the power
units, activating these from the PC.
Sending audio from the DC-
600ETH desk to the power units
(digital audio from the desk to the
DVA-102ETH, and analog audio from
the DVA-102ETH to the power units).
Zone selection from the DC-
600ETH desk or from the PC, using
the output contacts of the DVA-
102ETH (in the diagram, Ct1, Ct2 and
Ct3).
Through the configuration of the
input contacts of the DVA-102ETH (in
the diagram, contacts 3, 4 and 5), an
analog
microphone
with
zone
selection (MD-94R6) can be used.
When a zone is selected from the
MD-94R6 desk, the DVA-102ETH
activates
the
output
contact
corresponding to the zone selected.
Reception of system incidents and
alarms by the PC, the DVA-102ETH
and the DC-600ETH desk.
Broadcast of ETH music (music
source connected to the DC-600ETH
desk in the installation).