5.4.1

Installation steps

Clean mounting surface (1) carefully.

Remove protective foil (2) from the adhesive side of the magnetic strip (3).

Stick down the magnetic strip (4).

Clean surface of magnetic strip carefully.

Remove protective foil (6) from adhesive tape on the cover strip (5).

Fix cover strip (both ends should slightly overlap).

Secure the overlapping ends of the cover against detachment .

ATTENTION! 

Do not expose the system to magnetic fields. Any direct contact of the magnetic strip with

magnetic fields (e.g. adhesive magnets or other permanent magnets) is to be avoided. Sensor
movements during power loss are not captured by the follower electronics.

5.4.2 Installation examples 

Mounting with chamfered ends 
(



 Img.5-1:)  is not recommended unless the strip is installed in a safe and protected place without envi-

ronmental influences. In less protected mounting places the strip may peel. In such cases are mounting
methods more suitable as shown in 



 Img.5-2: and 



 Img.5-3:.  Best protects the assembly in a groove 



 Img.5-4: which should be so deep that the magnetic tape can be completely embedded therein.

1

4

6

5

3

2

Img.5-1:

Img.5-2:

Img.5-3:

Img.5-4:

Содержание 3383975

Страница 1: ...OPTIMUM M A S C H I N E N G E R M A N Y Dreiachs Positionsanzeige Three axes position display DRO 5 Artikel Nr Item no 3383975 Version 1 0 4 Betriebsanleitung de Operating manual en...

Страница 2: ...trations of the digital display may be different from the illustrations in these instructions with regard to a few details However this does not have any influence on the operability of the digital di...

Страница 3: ...ersonnel cause personal injury serious damage to machine or actuator Configuration commissioning mounting and maintenance by trained expert personnel only This personnel must be able to recognize dang...

Страница 4: ...mm Resolution 0 05 mm 50 m Magnetic tape item no 3383979 Length in a piece 2000 mm Resolution 0 05 mm 50 m Magnetic tape item no 3383980 Bulk stock Resolution 0 05 mm 50 m 3 Installation 3 1 Mechanica...

Страница 5: ...housings Contactor coils must be wired with spark suppression 3 2 1 Power supply speed sensor Power is supplied via the rear jack plug Connect the sensor for speed measurement from the scope of delive...

Страница 6: ...peed display Counting resolution setting function Counting direction setting Linear error compensation Metric inches change over LCD display status setting Speed mode setting Basic value setting 4 1 K...

Страница 7: ...the cursor to the specified options the PROG key is used to select For optional items using key to select and using the PROG key to exit after completing For modifying items using key to modify the d...

Страница 8: ...and speed axis X axis parameter Three level menu press PROG key to enter to modify the X axis parameter Y axis parameter Three level menu press PROG key to enter to modify the Y axis parameter Z axis...

Страница 9: ...ust be protected against environmental influences such as sprayed water solvent dust shocks vibra tions temperature fluctuations 5 4 Installation magnetic strip The mounting surface measuring track mu...

Страница 10: ...e the system to magnetic fields Any direct contact of the magnetic strip with magnetic fields e g adhesive magnets or other permanent magnets is to be avoided Sensor movements during power loss are no...

Страница 11: ...n This can be ignored if counting direction can be changed via the follower electronics Img 5 5 Definition of counting direction Distance measurements between sensor and magnetic tape and angular tole...

Страница 12: ...h interference if necessary a protective screen or metal housing must be provided The running of wiring parallel to the mains supply should be avoided Contactor coils must be wired with spark suppress...

Страница 13: ...tive read head MPA4 DRO5 no Read head different magnetic stripe differ ently DPA22 DRO5 no Connector differ ently active read head DRO3 DRO5 no Connector differently active read head DPM1 DRO5 no othe...

Страница 14: ...ion display Type designation DRO 5 Year of manufacture __ __ __ __ Digital position display for using on machine tools for path measurement in conjunction with magnetic sen sors which meets all the re...